Dold 0065120 MH9300.12PS/022 3AC24-690V AC12A multifunction measuring relay UH=DC24V
|
409,46 EUR |
|||||||||||
|
( 487,26 EUR incl. VAT ) ≈ £343.13 | ≈ $449.59 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001904 | ||||||||||
| Mfg Part No: | 0065120 | ||||||||||
| UPC/EAN: | 4030641651206 | ||||||||||
| Weight: | 0.25 kg | ||||||||||
| Type: | MH9300.12PS/022 3AC24-690V AC12A | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0065120:
Applications
This measuring relay is suitable for monitoring single- and three-phase electrical loads, emergency power supplies, voltage-dependent switching operations in cases of over- or under-voltage, and for monitoring mobile equipment. It is particularly used in motor protection for phase faults and in transformer protection for unsymmetrical loading. Frequency monitoring is also intended for applications with frequency converters.
Functions and Equipment in Detail
The device features two independent relay outputs, each with a 1-changeover contact. The monitoring functions can be individually parameterized, with each function assignable to one or both relays. The relay function can be switched between operating and resting current principle. The response delay and start-up bypass time ensure that short-term voltage fluctuations after switching on the auxiliary voltage do not lead to false tripping. The adjustable hysteresis of 0.2 to 50 % of the setpoint value allows precise adjustment of switching thresholds. A fault memory documents the last fault conditions, simplifying fault diagnosis on the device.
Technology Explained Simply
Measurement is performed via terminals L1, L2, and L3, with a minimum measurement voltage of 20 V between L1/L2 required to ensure proper operation. The measurement ranges include voltages from 3 AC 24 to 690 V, with the standard measurement range being 3 AC 24 to 400 V. The maximum measurement current is AC 12 A. Display is via an LCD screen showing current measurement values. Status indication is provided by LEDs: green for present auxiliary voltage, red flashing for overload in the current path, and orange for missing measurement or input mode. The terminal type consists of removable terminal blocks with screw terminals, facilitating replacement and maintenance.
Compatibility and Accessories
The device is designed for use in enclosures and has a width of 45 mm. It is available with plug-in connection blocks, which can be equipped with either screw terminals or spring-cage terminals. The auxiliary voltage is DC 24 V, although the series also offers variants with AC 230 V or AC/DC 110–400 V. The DNV certification is relevant for use in specific industrial environments.
Mounting and Installation
Mounting is performed in standard enclosures. The terminals are designed to allow easy and secure connections. Parameterization is done via an intuitive menu structure on the device, enabling setup and diagnosis without additional equipment. The connection terminals are removable, allowing device replacement without complete rewiring.
Advantages in Operation
Simultaneous monitoring of multiple parameters enables early detection of impending failures, supporting preventive maintenance and avoiding costly damage. Reduced wiring and compact design increase installation efficiency. The clear LCD display and differentiated fault messages simplify operational monitoring and fault resolution. Reliability and availability of the system are enhanced through continuous monitoring and rapid response to deviations.
| Technical data | |
| 1- / 3-phase | 1, 3 |
| Enclosure design | Switch cabinet |
| Measuring range max. | 690 V |
| Output contacts | 2 x 1 C/O contacts |
| Standard measuring range | 3 AC 24 - 400 V |
| Width | 45 mm |
| Type | MH 9300 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | DC 24 V |
| Contact equipping | 2 x 1 changeover contact |
| Measuring current | AC 12 A |
| Measuring voltage | 3AC 24 - 690 V |
| Terminal type | pluggable terminal blocks with screw terminals |
| Approvals and Markings | DNV |
Questions & answers
What is the delivery time of Dold 0065120 MH9300.12PS/022 3AC24-690V AC12A multifunction measuring relay UH=DC24V?
The article Dold 0065120 MH9300.12PS/022 3AC24-690V AC12A multifunction measuring relay UH=DC24V is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0065120 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0065120 MH9300.12PS/022 3AC24-690V AC12A multifunction measuring relay UH=DC24V always at the best possible price. We can give you a discount of 2% on Dold 0065120 MH9300.12PS/022 3AC24-690V AC12A multifunction measuring relay UH=DC24V if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0065120 MH9300.12PS/022 3AC24-690V AC12A multifunction measuring relay UH=DC24V we can offer you a price of 391,03 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.