Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor

Your rating:
Average rating
product review for Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor
( 4.4 / 5 ) 12 ratings
Dold 0065075
This image may differ from the desired article.
120,84 EUR
( 143,80 EUR incl. VAT )
≈ £101.26  |  ≈ $132.68
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor
Datasheet:file_download Download
Lieske Part No.:1338901
Mfg Part No: 0065075
UPC/EAN: 4030641650759
Weight:0.123 kg
Type:RK9872.11 3/N AC400/230V 50/60HZ
Graduated prices net
From piecesPrice per pieces
5116,31 EUR
10111,78 EUR
15107,25 EUR
20102,71 EUR

Product information for Dold 0065075:

The phase monitor RK9872.11 from Dold is a compact monitoring device for three-phase networks with nominal voltage 3/N AC 400/230 V. It is used for continuous monitoring of undervoltage, overvoltage, and phase sequence in electrical installations, particularly in applications with three-phase motors, overhead cranes, elevators, escalators, pumps, or filling and emptying systems. The device operates on the zero-current principle, in which the output relay is not activated in the event of a fault, ensuring a safe disconnection. The trigger values for undervoltage and overvoltage are fixed and measured against the neutral conductor (N).

Applications

The phase monitor is designed for use in industrial and commercial installations where reliable network monitoring is required. It is particularly suitable for installations where incorrect phase sequence or voltage fluctuations could cause damage to motors or machinery. The width of 17.5 mm allows for space-saving installation in installation distributors.

Functions and equipment in detail

The device monitors the arithmetic mean of the three phase voltages against the neutral conductor. In a fault-free network with correct clockwise phase sequence, the relay switches to the good state. If an incorrect phase sequence (counterclockwise rotation field) is detected, the yellow LED blinks three times, and the output relay remains deactivated. In the event of undervoltage (below 195.5 V) or overvoltage (above 253 V) lasting longer than 50 ms, the relay drops out. The yellow LED blinks once for undervoltage and twice for overvoltage to indicate the type of fault. The green LED lights up when supply voltage is present.

Technology explained simply

The switching thresholds are fixed: undervoltage is detected at 195.5 V, overvoltage at 253 V. The hysteresis is 2.5 %, ensuring stable switching behavior even with minor voltage fluctuations. The response time is under 50 ms, enabling fast fault detection. The measurement frequency is in the range of 45 to 65 Hz, ensuring compatibility with networks with nominal frequencies of 50 and 60 Hz. The device is designed for continuous operation and consumes approximately 6 VA.

Compatibility and accessories

The phase monitor is designed for 3-phase networks with nominal voltage 3/N AC 400/230 V. It can also be used in 1-phase installations with 400 V or 110 V, with corresponding adjusted trigger values (360 V/99 V for undervoltage, 440 V/121 V for overvoltage). The contact configuration includes a changeover contact rated for AC 15 circuits: make contact up to 2 A/AC 230 V, break contact up to 1 A/AC 230 V. The electrical life expectancy is at least 100,000 switching operations at 1 A/AC 230 V, and the mechanical life expectancy is 1,000,000 switching operations.

Mounting and installation

The device is mounted in installation distributors and is designed for mounting in switchboards. Connections are made via inputs L1, L2, L3, and N. Mounting must only be carried out when de-energized. The device display with green and yellow LEDs enables visual monitoring of the operating status. Safety instructions emphasize that faults must only be rectified when the device is switched off and adjustment work must only be carried out by trained personnel.

Advantages in operation

By simultaneously monitoring undervoltage, overvoltage, and phase sequence, the RK9872.11 enables rapid fault localization and preventive maintenance. The space-saving design and integrated LED display reduce installation effort and improve operational monitoring. The device complies with standard IEC/EN 60255-1 and is marked with the UKCA symbol. The overvoltage category III (according to IEC 60664-1) ensures robust operational safety in industrial environments. The operating temperature range is between -25 °C and +60 °C, and the storage temperature up to +70 °C.

Technical data
1- / 3-phase3
Enclosure designDistribution board
Measuring range max.400 V
Output contacts1 C/O contact
Standard measuring range3/N AC 400/230 V
Width17,5 mm
TypeRK 9872
Variant
Contact equipping1 changeover contact
Nominal voltage3/N AC 400 / 230 V
Approvals and MarkingsUKCA
VariantDe-energized on trip. Without time delay. Monitoring of undervoltage, overvoltage and phase sequence


Product data sheet
Datasheet for Dold 0065075, EAN: 4030641650759

Questions & answers

What is the delivery time of Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor ?

The article Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0065075 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor always at the best possible price. We can give you a discount of 2% on Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor we can offer you a price of 116,31 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0065075 RK9872.11 phase monitor 3/N AC400/230V
Dold 0065075 RK9872.11 3/N AC400/230V 50/60Hz phase monitor
120,84 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0065075 RK9872.11 phase monitor 3/N AC400/230V
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
2 + 6 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.