Dold 0064860 RP9810.13/100 3/N AC400/230V
|
665,53 EUR |
|||||||||||
|
( 791,98 EUR incl. VAT ) ≈ £557.71 | ≈ $730.75 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1152356 | ||||||||||
| Mfg Part No: | 0064860 | ||||||||||
| UPC/EAN: | 4030641648602 | ||||||||||
| Weight: | 0.2 kg | ||||||||||
| Type: | RP9810.13/100 3/N AC400/230V <30KVA | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0064860:
Applications
The RP9810.13/100 is intended for non-regulated self-generation plants, such as photovoltaic systems, wind turbines, combined heat and power plants, or hydropower plants. It ensures protection of the public grid and the own plant by monitoring voltage and frequency limit values. Disconnection occurs if these values are exceeded or undershot, to maintain grid stability. The plant can be reconnected to the grid after an adjustable delay time tw, provided voltage and frequency remain continuously within the tolerance range. In case of a short interruption, reconnection occurs after 5 seconds if the values are stable. Disconnection due to failure of the operating voltage occurs without the condition of a short interruption.
Functions and Equipment in Detail
The setting of voltage and frequency limit values is done via detent rotary switches, which are pre-set according to VDE-AR-N 4105:2011-08 at the time of delivery. The limit value for voltage drop protection is fixed at 80 % of the nominal voltage. The set values are simultaneously visible, enabling quick verification. An additional fault indicator relay signals disturbances. The display is via a multi-coloured, illuminated LCD screen, showing the operating status, measured values, and fault memory. The display can be switched using a button. A tamper-proof transparent cover protects against manipulation. Island grid detection recognises when the plant is disconnected from the public grid. A test button allows checking of functions. The device includes a release input, for example for radio control receivers, and monitors coupling switches with reaction time measurement.
Technology Explained Simply
The device is built with two channels, each controlling its own output relay. This ensures fail-safe operation, as a failure in one channel does not cause complete malfunction. The output contacts consist of three changeover contacts, used for controlling the coupling switches. The response delay is activated to enable stable reaction to short-term voltage fluctuations. High measurement accuracy ensures reliable decisions for disconnection or reconnection. Random-controlled disconnection in the range of 50.2 Hz to 51.5 Hz prevents resonance in non-regulated plants.
Compatibility and Accessories
The device is designed for use in self-generation plants connected to the low-voltage grid. It is designed for plants with a power rating below 30 kVA, with a variant also available for plants above 30 kVA. The terminal connections are intended for controlling coupling switches (11, 12, 14 and 21, 22, 24), fault indicator relays (31, 32, 34), and release inputs (X1, B1 / X2, B2). The feedback circuit of the coupling switches is connected via KA and KE. Installation is carried out in an installation distributor, with a width of 70 mm.
Mounting and Installation
Mounting is done in an installation distributor, with the device designed in format 4TE. Dimensions are 70 mm (width) × 90 mm (height) × 71 mm (depth). The terminal connections are clearly labelled to ensure correct wiring. Settings can be secured after commissioning via the tamper-proof front cover to prevent manipulation. Wiring is done according to the wiring diagram, which shows the assignment of terminals to functions.
Advantages in Operation
The RP9810.13/100 offers high reliability due to its two-channel design and fail-safe operation. Simple adjustment via rotary switches and visible display of values facilitate commissioning and maintenance. Quick diagnosis via the LCD display and fault memory support troubleshooting. Automatic reconnection after an adjustable delay and island grid detection increase operational safety. Compatibility with applicable standards and regulations ensures proper integration into existing plants. The device is designed for use in non-regulated plants, with random-controlled disconnection in the frequency range of 50.2 Hz to 51.5 Hz providing additional safety.
| Technical data | |
| 1- / 3-phase | 3 |
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Output contacts | 3 C/O contacts |
| Width | 70 mm |
| Type | RP 9810 |
| Operate delay | |
| Variant | |
| Contact equipping | 3 changeover contacts |
| Generator system power | < 30 kVA |
| Supply voltage | 3/N AC 400/230 V |
Questions & answers
What is the delivery time of Dold 0064860 RP9810.13/100 3/N AC400/230V?
The article Dold 0064860 RP9810.13/100 3/N AC400/230V is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0064860 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0064860 RP9810.13/100 3/N AC400/230V always at the best possible price. We can give you a discount of 2% on Dold 0064860 RP9810.13/100 3/N AC400/230V if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0064860 RP9810.13/100 3/N AC400/230V we can offer you a price of 635,58 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.