Further information for Dold 0064860 RP9810.13/100 3/N AC400/230V <30KVA voltage/frequency monitor
Technical data
1- / 3-phase
3
Auxiliary voltage
Without
Enclosure design
Distribution board
Output contacts
3 C/O contacts
Width
70 mm
Type
RP 9810
Operate delay
Variant
Contact equipping
3 changeover contacts
Generator system power
< 30 kVA
Supply voltage
3/N AC 400/230 V
The voltage and frequency monitor RP9810.13/100 from Dold is a two-channel monitoring device for self-generation plants connected to the low-voltage grid. It monitors the grid voltage and frequency of the network operator and ensures safe disconnection of the generation plant in case of faults. The device is designed for plants with a power rating below 30 kVA and operates with a supply voltage of 3/N AC 400/230 V. Monitoring is performed in three phases, measuring voltages between the line conductors and the neutral conductor. Additionally, the line-to-line voltages are calculated and evaluated. Frequency is measured single-phase in phase L1. The device is designed in installation format, with a width of 70 mm, and complies with standards VDE-AR-N 4105:2011-08, DIN VDE 0126-1-1:2013-08, and DIN EN 60255-1. It is suitable for use according to EEG 2012 and SysStabV.
Applications
The RP9810.13/100 is intended for non-regulated self-generation plants, such as photovoltaic systems, wind turbines, combined heat and power plants, or hydropower plants. It ensures protection of the public grid and the own plant by monitoring voltage and frequency limit values. Disconnection occurs if these values are exceeded or undershot, to maintain grid stability. The plant can be reconnected to the grid after an adjustable delay time tw, provided voltage and frequency remain continuously within the tolerance range. In case of a short interruption, reconnection occurs after 5 seconds if the values are stable. Disconnection due to failure of the operating voltage occurs without the condition of a short interruption.
Functions and Equipment in Detail
The setting of voltage and frequency limit values is done via detent rotary switches, which are pre-set according to VDE-AR-N 4105:2011-08 at the time of delivery. The limit value for voltage drop protection is fixed at 80 % of the nominal voltage. The set values are simultaneously visible, enabling quick verification. An additional fault indicator relay signals disturbances. The display is via a multi-coloured, illuminated LCD screen, showing the operating status, measured values, and fault memory. The display can be switched using a button. A tamper-proof transparent cover protects against manipulation. Island grid detection recognises when the plant is disconnected from the public grid. A test button allows checking of functions. The device includes a release input, for example for radio control receivers, and monitors coupling switches with reaction time measurement.
Technology Explained Simply
The device is built with two channels, each controlling its own output relay. This ensures fail-safe operation, as a failure in one channel does not cause complete malfunction. The output contacts consist of three changeover contacts, used for controlling the coupling switches. The response delay is activated to enable stable reaction to short-term voltage fluctuations. High measurement accuracy ensures reliable decisions for disconnection or reconnection. Random-controlled disconnection in the range of 50.2 Hz to 51.5 Hz prevents resonance in non-regulated plants.
Compatibility and Accessories
The device is designed for use in self-generation plants connected to the low-voltage grid. It is designed for plants with a power rating below 30 kVA, with a variant also available for plants above 30 kVA. The terminal connections are intended for controlling coupling switches (11, 12, 14 and 21, 22, 24), fault indicator relays (31, 32, 34), and release inputs (X1, B1 / X2, B2). The feedback circuit of the coupling switches is connected via KA and KE. Installation is carried out in an installation distributor, with a width of 70 mm.
Mounting and Installation
Mounting is done in an installation distributor, with the device designed in format 4TE. Dimensions are 70 mm (width) × 90 mm (height) × 71 mm (depth). The terminal connections are clearly labelled to ensure correct wiring. Settings can be secured after commissioning via the tamper-proof front cover to prevent manipulation. Wiring is done according to the wiring diagram, which shows the assignment of terminals to functions.
Advantages in Operation
The RP9810.13/100 offers high reliability due to its two-channel design and fail-safe operation. Simple adjustment via rotary switches and visible display of values facilitate commissioning and maintenance. Quick diagnosis via the LCD display and fault memory support troubleshooting. Automatic reconnection after an adjustable delay and island grid detection increase operational safety. Compatibility with applicable standards and regulations ensures proper integration into existing plants. The device is designed for use in non-regulated plants, with random-controlled disconnection in the frequency range of 50.2 Hz to 51.5 Hz providing additional safety.