Dold 0063869 BA9053/010 AC1.5-15A AC/DC24-80V current relay Tv=0-100S
|
335,41 EUR |
|||||||||||
|
( 399,14 EUR incl. VAT ) ≈ £280.74 | ≈ $368.62 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 593079 | ||||||||||
| Mfg Part No: | 0063869 | ||||||||||
| UPC/EAN: | 4030641638696 | ||||||||||
| Weight: | 0.23 kg | ||||||||||
| Type: | BA9053/010 AC1,5-15A AC/DC24-80V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0063869:
Applications
The relay is suitable for use in industrial plants and railway applications where reliable current monitoring is required. It monitors the arithmetic mean of the rectified measured current and is calibrated for sinusoidal AC currents in RMS value. The galvanic isolation between auxiliary circuit and measuring circuit ensures safe and interference-free signal transmission. The measuring ranges cover AC 1.5 to 15 A, and the devices are equally usable for DC and AC. The maximum measuring frequency is 5 kHz, enabling accurate detection even during rapid signal changes.
Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which can be used to control additional switching devices or alarms. The auxiliary voltage is AC/DC 24 to 80 V, allowing flexible integration into existing control systems. Indication is provided via two LEDs: a green LED indicates operational readiness, while a yellow LED signals activation of the output relay. The setting of the pickup and dropout values is done via rotary switches, with the hysteresis depending on the setpoint. The pickup delay is also integrated and ensures stable response to current changes.
Technology Explained Simply
The relay measures the current via an internal measuring resistor (shunt) and compares the measured value with the set threshold. When the setpoint is exceeded, the output contact switches after the switching delay has elapsed. The switching delay can be adjusted between 0 and 100 seconds, allowing adaptation to different requirements. The galvanic isolation between measuring and auxiliary circuit prevents interference and increases safety. The width is 45 mm, enabling compact mounting in enclosures.
Compatibility and Accessories
The relay is designed for use in enclosures and complies with standards IEC/EN 60255-1 and IEC/EN 60947-1. The UKCA and CCC certifications are valid for the respective variant. It can be used both as an overcurrent relay and as an undercurrent relay, with the hysteresis adjusted accordingly for undercurrent applications. The devices are designed for high overload capacity, with maximum permissible currents varying according to the measuring range. The terminal markings include auxiliary voltage (A1, A2), current input (i, k), and the two changeover contacts (11-14, 21-24).
Mounting and Installation
Mounting is done in an enclosure, with the width of 45 mm enabling standard installation. The connection terminals are clearly labeled, ensuring error-free wiring. The threshold values are adjusted via the rotary switches on the front panel, requiring no additional tools. The operating voltage is connected via terminals A1 and A2, while the measured current is supplied via terminals i and k.
Advantages in Operation
Early detection of current anomalies enables preventive maintenance and prevents costly failures. The LED indicators provide quick visual feedback on the operating status. The switching delay reduces false trips caused by short-term current peaks, increasing reliability. Galvanic isolation and high overload capacity ensure robust and safe operation in demanding environments. Compliance with standards IEC/EN 60255-1 and IEC/EN 60947-1 guarantees high quality and compatibility with other devices in the system.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9053 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC/DC 24 - 80 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 1,5 - 15 A |
| Start up delay | Without |
| Switching delay | 0 - 100 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overcurrent relay. Energized on trip. Time delay at response value |
Questions & answers
What is the delivery time of Dold 0063869 BA9053/010 AC1.5-15A AC/DC24-80V current relay Tv=0-100S ?
The article Dold 0063869 BA9053/010 AC1.5-15A AC/DC24-80V current relay Tv=0-100S is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0063869 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0063869 BA9053/010 AC1.5-15A AC/DC24-80V current relay Tv=0-100S always at the best possible price. We can give you a discount of 2% on Dold 0063869 BA9053/010 AC1.5-15A AC/DC24-80V current relay Tv=0-100S if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0063869 BA9053/010 AC1.5-15A AC/DC24-80V current relay Tv=0-100S we can offer you a price of 332,89 EUR per piece. The more you buy, the cheaper the article will be.