Dold 0063811 PH9270.91/002/02 AC24-110V AC40A semiconductor contactor UH24VDC
|
197,10 EUR |
|||||||||||
|
( 234,55 EUR incl. VAT ) ≈ £164.97 | ≈ $216.61 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001625 | ||||||||||
| Mfg Part No: | 0063811 | ||||||||||
| UPC/EAN: | 4030641638115 | ||||||||||
| Weight: | 0.11 kg | ||||||||||
| Type: | PH9270.91/002/02 AC24-110V AC40A | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0063811:
Applications
This semiconductor contactor is intended for frequent operation with heaters, motors, valves, and lighting systems. The integrated load circuit monitoring enables early detection of faults such as load circuit interruption, over- or under-current, missing load voltage, fuse failure, or thyristor faults. For overcurrent monitoring, a start-up bypass time must be provided in the control system to avoid misinterpreting the inrush current of motors or other inductive loads as a fault.
Functions and Features in Detail
The device features a PNP semiconductor alarm output operating on the rest current principle, which activates when a fault is detected. Status indication is provided by a dual-color LED: the LED A1/A5,1 cm ( 2 inch ) indicates the status of the control input (yellow = activated, off = not activated), while the LED "Alarm indicates the device status (green = no fault, red = fault, off = no auxiliary voltage). Monitoring is continuous as soon as the auxiliary voltage (A3+/A2) is applied.
Technology Explained Simply
The semiconductor contactor is based on two antiparallel-connected thyristors responsible for the switching function. The DCB technology (Direct-Copper-Bonding process) ensures optimal heat dissipation, increasing service life and reliability. The device is equipped with a heatsink that can be snapped onto a DIN rail, making it ready for immediate use. The width is 45 mm, enabling compact installation in enclosures. The load voltage range is AC 24–110 V, and the load current is AC 40 A, with a maximum load voltage up to AC 480 V and a maximum load current up to 40 A. The standard IEC/EN 60947-4-3 is complied with.
Compatibility and Accessories
The device is designed for use with PLC-compatible alarm outputs. Optionally, a temperature limit switch (normally open) can be inserted into the designated slot at the bottom to monitor the heatsink temperature. A suitable switch is the UCHIYA type UP62–100, which opens when the heatsink temperature exceeds 100 °C. The terminal connections are clearly labeled: A1+/A2 for the control input, A3+/A2 for the operating voltage and load circuit monitoring, Alarm for the semiconductor alarm output, L1 for the mains connection, and T1 for the load output.
Mounting and Installation
Mounting is done on a DIN rail, with the device snapping directly onto the integrated heatsink. Installation must be carried out exclusively by a qualified electrician. The shock protection class is IP 20, requiring use in enclosed enclosures.
Operational Advantages
The semiconductor contactor provides wear-free operation without mechanical contacts, increasing service life and extending maintenance intervals. The integrated load circuit monitoring enables rapid fault detection and indication, minimizing downtime. Zero-voltage switching reduces electrical interference and load stress. The combination of DCB technology and heatsink ensures efficient heat dissipation, enhancing reliability under load conditions. The PLC-compatible interface simplifies integration into existing control systems.
| Technical data | |
| Load current up to | 40 A |
| Load voltage up to | AC 480 V |
| Number of poles | 1-pole |
| On/Off Input Control | DC |
| Width | 45 mm |
| Type | PH 9270 |
| Signalling output | |
| Variant | |
| Auxiliary voltage | DC 24 V |
| Load current | AC 40 A |
| Load voltage | AC 24 - 110 V |
| Semiconductor output | 1-pole |
| Variant | Switching at zero crossing. With over current monitoring and PNP transistor output with de-energized on trip. With heat sink |
Questions & answers
What is the delivery time of Dold 0063811 PH9270.91/002/02 AC24-110V AC40A semiconductor contactor UH24VDC?
The article Dold 0063811 PH9270.91/002/02 AC24-110V AC40A semiconductor contactor UH24VDC is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0063811 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0063811 PH9270.91/002/02 AC24-110V AC40A semiconductor contactor UH24VDC always at the best possible price. We can give you a discount of 2% on Dold 0063811 PH9270.91/002/02 AC24-110V AC40A semiconductor contactor UH24VDC if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0063811 PH9270.91/002/02 AC24-110V AC40A semiconductor contactor UH24VDC we can offer you a price of 188,23 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.