Product information for Dold 0063333:
Applications
This semiconductor relay is intended for use in machine building and automation technology, particularly in the plastics and rubber industry, packaging machines, soldering systems or in the food industry. The peak voltage switching variant is especially suitable for applications where high inrush currents must be avoided, such as when switching transformers. Zero-voltage switching is standard, with the peak voltage switching variant representing a special configuration for this purpose.
Functions and Features in Detail
The device features two antiparallel-connected thyristors responsible for the switching function. The DCB technology (Direct-Copper-Bonding process) ensures excellent heat transfer, increasing thermal load capacity. The LED status indicator signals the status of the control input. The box terminals allow for secure and easy connection of wires. The device is delivered without a heatsink, although an optional heatsink for DIN rail mounting is available.
Technology Explained Simply
Switching in the peak voltage switching variant occurs at the maximum voltage point of the sinusoidal mains voltage, minimizing the inrush current. The blocking voltage is 1200 V or 1600 V, and the insulation voltage is 4000 V, ensuring high electrical safety. The maximum load voltage is AC 600 V, and the maximum load current is 125 A (AC-51), with the I²t limit value being 18000 A²s. The junction temperature must not exceed 125 °C. The operating temperature range is –20 °C to 40 °C, and the storage temperature range is –20 °C to 80 °C.
Compatibility and Accessories
The device is designed for industrial environments and complies with the requirements of the standard IEC/EN 60947-4-3. An optional over-temperature protection is available, activated by installing a temperature-limiting switch (e.g. UCHIYA type UP62–100) into a designated pocket on the underside. If the heatsink temperature exceeds the set limit (e.g. 100 °C), the switch opens and protects the device. Additionally, a variant with reduced electromagnetic emission is available, improving electromagnetic compatibility (EMC).
Mounting and Installation
The device is mounted on a DIN rail. The width of 45 mm allows for compact placement. The box terminals are designed for connecting wires. Mounting requires no additional tools, as the terminals can be connected directly. The touch protection class is IP20 at the terminals, and the housing is protected to IP40.
Operational Advantages
The semiconductor relay offers wear-free operation, as there are no mechanical contacts. Switching operations are noiseless, improving the working environment. The high switching capacity (up to 125 A) and robust construction with DCB technology ensure a long service life. The LED indicator allows for easy status monitoring. The peak voltage switching variant reduces the inrush current, increasing the lifespan of both the load and the relay. Compliance with the standard IEC/EN 60947-4-3 ensures safe and reliable operation in industrial installations.
| Technical data | |
| Load current up to | 125 A |
| Load voltage up to | AC 600 V |
| Number of poles | 1-pole |
| On/Off Input Control | AC/DC, DC |
| Width | 45 mm |
| Type | PH 9260 |
| Variant | |
| Control voltage | DC 4 - 32 V |
| Load current | AC 50 A |
| Load voltage | AC 100 - 240 V |
| Semiconductor output | 1-pole |
| Variant | Switching at voltage maximum. Without heat sink |
Questions & answers
What is the delivery time of Dold 0063333 PH9260.91/020 AC100-240V AC50A semiconductor relay UH=DC4-32V?
The article Dold 0063333 PH9260.91/020 AC100-240V AC50A semiconductor relay UH=DC4-32V is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0063333 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0063333 PH9260.91/020 AC100-240V AC50A semiconductor relay UH=DC4-32V always at the best possible price. We can give you a discount of 2% on Dold 0063333 PH9260.91/020 AC100-240V AC50A semiconductor relay UH=DC4-32V if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 6 pieces of Dold 0063333 PH9260.91/020 AC100-240V AC50A semiconductor relay UH=DC4-32V we can offer you a price of 51,59 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.