Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S

Your rating:
Average rating
product review for Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S
( 4.3 / 5 ) 6 ratings
Dold 0061398
This image may differ from the desired article.
335,41 EUR
( 399,14 EUR incl. VAT )
≈ £280.74  |  ≈ $368.62
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S
Datasheet:file_download Download
Lieske Part No.:330275
Mfg Part No: 0061398
UPC/EAN: 4030641613983
Weight:0.23 kg
Type:BA9054/012 AC50-500mV AC/DC80-230V
Graduated prices net
From piecesPrice per pieces
4332,89 EUR
8330,38 EUR
12327,86 EUR
16325,35 EUR

Product information for Dold 0061398:

The voltage relay BA9054/012 from Dold is an industrial device for monitoring single-phase DC and AC voltage networks. It is used for continuous monitoring of the network voltage to detect deviations from the setpoint early and thus prevent failures in electrical systems. The device operates on the principle of rest current and is configured as an undervoltage relay, with the switching delay activated upon reaching the hysteresis value. Adjustment is performed via rotary switches on the front of the device, enabling simple and user-friendly parameterization.

Applications
This relay is intended for use in industrial and railway applications where high operational safety and reliability of electrical systems are required. It monitors DC and AC voltages in the range of AC 50 to 500 mV, making it suitable for applications with very low voltage values, for example in control and regulation circuits. The galvanic isolation between auxiliary circuit and measurement circuit ensures safe and interference-free measurement, even in electrically demanding environments.

Functions and Equipment in Detail
The device features two changeover contacts, which can be used for controlling auxiliary circuits or warning signals. The auxiliary voltage is AC/DC 80 to 230 V, enabling flexible integration into existing power supply systems. The switching delay can be set between 0 and 20 seconds to avoid unwanted switching operations during short-term voltage fluctuations. The pickup delay is also integrated to ensure stable response to voltage changes.

Technology Explained Simply
The relay measures the arithmetic mean of the rectified measurement voltage. For AC voltages, the device is calibrated to the RMS value, enabling precise measurement even with sinusoidal voltages. The hysteresis, i.e., the difference between pickup and drop-out value, depends on the set pickup value and ensures that the relay does not switch uncontrollably due to minor fluctuations around the setpoint. The LED indicators (green for operational readiness, yellow for activated output relay) allow visual monitoring of the operating status.

Compatibility and Accessories
The relay is compliant with standards IEC/EN 60255-1 and IEC/EN 60947-1 and carries the certifications UKCA and CCC. It is designed for a maximum rated voltage of AC 1000 V and DC 900 V, with the measurement voltage in the range of AC 50–500 mV. The width is 45 mm, enabling installation in standard enclosures. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, e/f for voltage input, and contacts 11/12/14 and 21/22/24 for the two changeover contacts.

Mounting and Installation
Mounting is done in an enclosure, with the width of 45 mm allowing standard installation on DIN rails. The terminals are designed for secure connections, and the front view with rotary switches allows direct on-site adjustment. The galvanic isolation between measurement and auxiliary circuit reduces the risk of interference and increases safety.

Advantages in Operation
By detecting voltage deviations early, the relay supports preventive maintenance and prevents damage to connected devices. The precise and reliable measurement ensures high operational safety, while the LED indicators enable quick fault localization. The switching delay prevents unnecessary switching operations during short-term voltage fluctuations, increasing the service life of connected components.

Certifications and Markings
The device carries the certifications UKCA and CCC, confirming compliance with applicable safety and quality standards in the respective markets. The standards IEC/EN 60255-1 and IEC/EN 60947-1 ensure reliability and safety of the device in industrial applications.

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Nominal voltage max.AC 1000 V, DC 900 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9054
Operate delayYes
Variant
Auxiliary voltageAC/DC 80 - 230 V
Contact equipping2 changeover contacts
Measuring rangeAC 50 - 500 mV
Start up delayWithout
Switching delay0 - 20 s
Approvals and MarkingsUKCA, CCC
VariantUndervoltage relay. De-energized on trip. Time delay at hysteresis value


Product data sheet
Datasheet for Dold 0061398, EAN: 4030641613983

Questions & answers

What is the delivery time of Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S ?

The article Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0061398 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S always at the best possible price. We can give you a discount of 2% on Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S we can offer you a price of 332,89 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0061398 voltage relay AC50-500mV
Dold 0061398 BA9054/012 AC50-500mV AC/DC80-230V voltage relay Tv=0-20S
335,41 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0061398 voltage relay AC50-500mV
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
4 + 6 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.