Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s

Your rating:
Average rating
product review for Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s
( 4.3 / 5 ) 3 ratings
Dold 0060949
This image may differ from the desired article.
279,57 EUR
( 332,69 EUR incl. VAT )
≈ £234.00  |  ≈ $307.25
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s
Datasheet:file_download Download
Lieske Part No.:1001926
Mfg Part No: 0060949
UPC/EAN: 4030641609498
Weight:0.325 kg
Type:MH9143.39 +/-5Hz UH DC24V
Graduated prices net
From piecesPrice per pieces
4266,99 EUR
8254,41 EUR
12241,83 EUR
16229,25 EUR

Product information for Dold 0060949:

The network frequency monitor MH 9143.39 from Dold is an industrial monitoring switch for continuous checking of network frequency in 50- and 60-Hz systems. It is used for detecting over- and under-frequency conditions in self-generation plants, local power supplies, as well as in generators and power units. The device is designed for use in enclosures and provides precise frequency measurement with fast response time. The measuring input is designed to be interference-resistant, ensuring reliable measurements even under industrial conditions.

Applications

The MH 9143.39 is used in installations where stable frequency of the power supply is critical. This includes self-generation units such as diesel or gas engines, which are operated as backup power supplies or in decentralized networks. It is also suitable for monitoring power units and local networks that are not connected to a large public grid. The application is in industrial and technical environments, where frequency deviations can cause damage to machinery or operational disruptions.

Functions and Equipment in Detail

The device features two independent relay outputs, each with two changeover contacts, intended for over- and under-frequency alarms. The alarm thresholds are adjustable via a 10-step switch and range from ±0.1 Hz to ±5 Hz relative to the nominal frequency of 50 or 60 Hz. The nominal frequency can be switched between 50 Hz and 60 Hz. The alarm delay is separately adjustable for over- and under-frequency and ranges from 0 to 20 seconds. A start-up bypass can be activated via terminals and can be set between 0 and 30 seconds to ignore short-term frequency fluctuations during generator start-up.

Technology Explained Simply

Frequency measurement is performed via a universal input designed for AC voltages from 40 to 550 V. The device requires an auxiliary voltage of DC 24 V, which is necessary for operational safety and the function of the relay outputs. The output relays operate on the de-energized principle, i.e., they drop out when the alarm threshold is reached. The hysteresis is fixed and adapted to the measurement range to ensure stable switching behavior. LED indicators signal the operation of the auxiliary voltage, the current input frequency, and the alarm states for over- and under-frequency.

Compatibility and Accessories

The MH 9143.39 is part of the VARIMETER series from Dold and can be used in systems requiring frequency monitoring with separate relay outputs for over- and under-frequency. Devices in the MH 9143 series are available in various variants, with the variant described here, MH 9143.39, specifically designed for an auxiliary voltage of DC 24 V and a contact configuration of 2 x 2 changeover contacts. The devices are specified according to IEC / EN 60255-1, ensuring compliance with safety and functional standards for electrical equipment in measurement and monitoring technology.

Mounting and Installation

The device is designed for mounting in enclosures and has a width of 45 mm. The connection terminals are clearly labeled: A1 and A2 serve as auxiliary voltage connections, E0, E1, and E2 are the frequency inputs. The programming terminals X1, X2, and X3 allow adjustment of functions such as start-up bypass and alarm delay. Installation is carried out by directly connecting the input and output terminals to the corresponding lines of the system to be monitored.

Advantages in Operation

The separate relay outputs for over- and under-frequency enable differentiated responses to frequency deviations, e.g., through different switching operations or alarms. The adjustable alarm delays and start-up bypass prevent false alarms during short-term fluctuations. The clear LED display facilitates diagnosis during operation. The device is designed for industrial environments and provides a reliable, low-maintenance monitoring solution for critical power supplies.

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Measuring range max.50/60 Hz
Output contacts2 x 2 C/O contacts
Standard measuring range50/60 Hz
Width45 mm
TypeMH 9143
Auxiliary voltage requiredYes
Operate delayYes
Variant
Alarm delay0 - 20 s
Auxiliary voltageDC 24 V
Contact equipping2 x 2 changeover contacts
Response value+ / - [0.1 - 5] Hz
Start up delay0 - 30 s
VariantAdjustable tripping values via 10-step switch. Adjustable time delay. Start up delay activatable via terminals


Product data sheet
Datasheet for Dold 0060949, EAN: 4030641609498

Questions & answers

What is the delivery time of Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s?

The article Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0060949 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s always at the best possible price. We can give you a discount of 2% on Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s we can offer you a price of 266,99 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0060949 MH9143.39 +/-5Hz UH DC24V frequency monitor
Dold 0060949 MH9143.39 +/-5Hz UH DC24V mains frequency monitor Tv=0-20s Tanl=0-30s
279,57 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0060949 MH9143.39 +/-5Hz UH DC24V frequency monitor
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
1 + 8 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.