Dold 0060949 MH9143.39 +/-5Hz UH DC24V frequency monitor

Dold 0060949 MH9143.39 +/-5Hz UH DC24V frequency monitor

Lieske Part No. 1001926
Mfg Part No 0060949
EAN-Code 4030641609498
Manufacturer Dold
Here only 279,57 EUR
332,69 EUR incl. VAT

Further information for Dold 0060949 MH9143.39 +/-5Hz UH DC24V frequency monitor

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Measuring range max.50/60 Hz
Output contacts2 x 2 C/O contacts
Standard measuring range50/60 Hz
Width45 mm
TypeMH 9143
Auxiliary voltage requiredYes
Operate delayYes
Variant
Alarm delay0 - 20 s
Auxiliary voltageDC 24 V
Contact equipping2 x 2 changeover contacts
Response value+ / - [0.1 - 5] Hz
Start up delay0 - 30 s
VariantAdjustable tripping values via 10-step switch. Adjustable time delay. Start up delay activatable via terminals
The network frequency monitor MH 9143.39 from Dold is an industrial monitoring switch for continuous checking of network frequency in 50- and 60-Hz systems. It is used for detecting over- and under-frequency conditions in self-generation plants, local power supplies, as well as in generators and power units. The device is designed for use in enclosures and provides precise frequency measurement with fast response time. The measuring input is designed to be interference-resistant, ensuring reliable measurements even under industrial conditions.

Applications

The MH 9143.39 is used in installations where stable frequency of the power supply is critical. This includes self-generation units such as diesel or gas engines, which are operated as backup power supplies or in decentralized networks. It is also suitable for monitoring power units and local networks that are not connected to a large public grid. The application is in industrial and technical environments, where frequency deviations can cause damage to machinery or operational disruptions.

Functions and Equipment in Detail

The device features two independent relay outputs, each with two changeover contacts, intended for over- and under-frequency alarms. The alarm thresholds are adjustable via a 10-step switch and range from ±0.1 Hz to ±5 Hz relative to the nominal frequency of 50 or 60 Hz. The nominal frequency can be switched between 50 Hz and 60 Hz. The alarm delay is separately adjustable for over- and under-frequency and ranges from 0 to 20 seconds. A start-up bypass can be activated via terminals and can be set between 0 and 30 seconds to ignore short-term frequency fluctuations during generator start-up.

Technology Explained Simply

Frequency measurement is performed via a universal input designed for AC voltages from 40 to 550 V. The device requires an auxiliary voltage of DC 24 V, which is necessary for operational safety and the function of the relay outputs. The output relays operate on the de-energized principle, i.e., they drop out when the alarm threshold is reached. The hysteresis is fixed and adapted to the measurement range to ensure stable switching behavior. LED indicators signal the operation of the auxiliary voltage, the current input frequency, and the alarm states for over- and under-frequency.

Compatibility and Accessories

The MH 9143.39 is part of the VARIMETER series from Dold and can be used in systems requiring frequency monitoring with separate relay outputs for over- and under-frequency. Devices in the MH 9143 series are available in various variants, with the variant described here, MH 9143.39, specifically designed for an auxiliary voltage of DC 24 V and a contact configuration of 2 x 2 changeover contacts. The devices are specified according to IEC / EN 60255-1, ensuring compliance with safety and functional standards for electrical equipment in measurement and monitoring technology.

Mounting and Installation

The device is designed for mounting in enclosures and has a width of 45 mm. The connection terminals are clearly labeled: A1 and A2 serve as auxiliary voltage connections, E0, E1, and E2 are the frequency inputs. The programming terminals X1, X2, and X3 allow adjustment of functions such as start-up bypass and alarm delay. Installation is carried out by directly connecting the input and output terminals to the corresponding lines of the system to be monitored.

Advantages in Operation

The separate relay outputs for over- and under-frequency enable differentiated responses to frequency deviations, e.g., through different switching operations or alarms. The adjustable alarm delays and start-up bypass prevent false alarms during short-term fluctuations. The clear LED display facilitates diagnosis during operation. The device is designed for industrial environments and provides a reliable, low-maintenance monitoring solution for critical power supplies.