Product information for Dold 0060018:
Applications
This semiconductor relay is suitable for use in machine building and automation technology, particularly in injection moulding machines, extruders, thermoforming and blow moulding machines, packaging machines and soldering systems. It is also used in the food industry, where reliable and maintenance-free control of heating elements and motors is required. The integrated load circuit monitoring enables early detection of faults such as load circuit interruption, over- or under-current, thyristor defects or missing mains voltage.
Functions and equipment in detail
The device features a PNP semiconductor alarm output operating on the rest current principle, which is activated when a fault is detected. Fault detection is achieved through continuous monitoring of load voltage and load current. The load current threshold is adjustable, enabling precise monitoring of load conditions. Indication is provided via a dual-color LED: LED A1/A5,1 cm ( 2 inch ) indicates the status of the control input (yellow = activated, off = not activated), while LED "Alarm indicates the device status (green = no fault, red = fault, off = no auxiliary voltage). In the event of a fault, the alarm output is activated and is compatible with a PLC.
Technology explained simply
The relay is based on two antiparallel-connected thyristors, which handle switching in the alternating current circuit. Switching occurs at the voltage zero crossing, ensuring high service life and low electromagnetic interference. The DCB technology (Direct-Copper-Bonding process) ensures optimal heat dissipation, reducing thermal stress on the device. The device is delivered without a heatsink, although an optional heatsink for DIN rail mounting is available to further improve heat dissipation.
Compatibility and accessories
The device complies with IEC/EN 60947-4-3 standards and is designed for use in industrial control systems. It is equipped with a PLC-compatible alarm output (PNP), allowing direct integration into existing automation systems. An optional over-temperature protection device is available, where a temperature limit switch (normally open) can be inserted into a designated pocket on the underside of the device. If the heatsink temperature exceeds the set limit (e.g. 100 °C), the switch opens and protects the device from thermal overload. An example of a suitable temperature limit switch is the type UP62 – 100 from UCHIYA.
Mounting and installation
Mounting is on standard DIN rail, with the 45 mm width enabling compact placement. Installation must be carried out by a qualified electrician, as connections to the mains and load circuit, as well as the control interface, are safety-critical. Terminal markings are clearly defined: A1+/A2 for the control input, A3+/A2 for operating voltage and load circuit monitoring, L1 for mains connection and T1 for load output. The terminal connections are designed for secure and reliable connections.
Advantages in operation
The semiconductor relay offers wear-free operation without mechanical contacts, increasing service life and reducing maintenance intervals. The integrated load circuit monitoring enables rapid fault detection and indication, minimizing downtime. The zero-voltage switching reduces electromagnetic interference and protects sensitive electronic components. The combination of high load current capacity (40 A) and integrated diagnostic function makes the device a reliable solution for demanding industrial applications.
| Technical data | |
| Load current up to | 40 A |
| Load voltage up to | AC 480 V |
| Number of poles | 1-pole |
| On/Off Input Control | DC |
| Width | 45 mm |
| Type | PH 9270 |
| Signalling output | |
| Variant | |
| Auxiliary voltage | DC 24 V |
| Load current | AC 40 A |
| Load voltage | AC 200 - 480 V |
| Semiconductor output | 1-pole |
| Variant | Switching at zero crossing. With heigh I2t-value. Control via A1/A2 with under- and over current monitoring and PNP transistor output with de-energized on trip. Without heat sink |
Questions & answers
What is the delivery time of Dold 0060018 PH9270.91/100 AC200-480V AC40A semiconductor relay UH24VDC?
The article Dold 0060018 PH9270.91/100 AC200-480V AC40A semiconductor relay UH24VDC is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0060018 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0060018 PH9270.91/100 AC200-480V AC40A semiconductor relay UH24VDC always at the best possible price. We can give you a discount of 2% on Dold 0060018 PH9270.91/100 AC200-480V AC40A semiconductor relay UH24VDC if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0060018 PH9270.91/100 AC200-480V AC40A semiconductor relay UH24VDC we can offer you a price of 153,77 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.