Dold 0059428 SP9270.12CT overload relay AC220-240V 10-100A Tv=0.1-20S
|
516,01 EUR 537,74 EUR |
|||||||||||
|
( 614,05 EUR incl. VAT ) ≈ £431.90 | ≈ $567.09 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 501244 | ||||||||||
| Mfg Part No: | 0059428 | ||||||||||
| UPC/EAN: | 4030641594282 | ||||||||||
| Weight: | 0.224 kg | ||||||||||
| Type: | SP9270.12CT AC220-240V 10-100A | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0059428:
Applications
This relay is designed for use in industrial and technical installations where precise current monitoring is required. It is suitable, for example, for protective functions for motors, transformers, or other electrical consumers that must be protected against overload. The galvanic isolation between the auxiliary circuit and the measurement circuit ensures high safety and prevents interference in the control circuit. The 3-phase measurement enables simultaneous monitoring of all three phases, which is crucial for operational safety in three-phase installations.
Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which can be used to control auxiliary circuits or alarms. The pickup value is adjustable, allowing the relay to be flexibly adapted to different loads and requirements. The hysteresis is fixed at approximately 4 %, ensuring stable switching behavior during current fluctuations. The LED indicators signal the operating status: a green LED indicates that the current is within acceptable limits, while a red LED lights up in case of overcurrent. The display is directly visible to the operator and enables quick fault detection.
Technology Explained Simply
The SP9270.12CT integrates a current transformer, which makes the monitored current measurable without requiring direct electrical connections to the main circuit. The measurement is performed by passing the conductors through the transformer, thereby inductively detecting the current. The auxiliary voltage is supplied via terminals A1/A2 and powers the relay with the necessary energy for controlling the contacts. The time delay allows short-term load peaks, which are not harmful, to be ignored, while sustained overloads are reliably detected.
Compatibility and Accessories
The device is designed for use in enclosures and corresponds to the enclosure form enclosure. The width is 70 mm, making it suitable for standard enclosure mounting. It is manufactured in accordance with IEC/EN 60 255-1, confirming compliance with international standards for electrical measuring instruments and relays. It can be combined with other devices from the SP-9270 series, especially in configurations requiring 3-phase monitoring. The connection terminals are located at the top, which is typical for the S form factor and facilitates installation in enclosures with mounting plate and cable duct.
Mounting and Installation
Mounting is performed in enclosures with a mounting plate. The connection terminals are positioned at the top, enabling easy wiring. The depth is 100 mm, providing sufficient space for wiring and secure installation. The terminal designation is clearly defined: A1/A2 for auxiliary voltage, i1/k1 to i3/k3 for the measurement circuits of the three phases, and Z1/Z2, Z3/Z4 are used for selecting the measurement range via bridges.
Advantages in Operation
The SP9270.12CT offers reliable and precise current monitoring with adjustable parameters that can be adapted to the specific application. The galvanic isolation between the measurement and auxiliary circuits increases safety. The LED indicators enable quick visual monitoring of the operating status. The adjustable time delay reduces false alarms caused by short-term load peaks. The device is designed for use in industrial environments and complies with applicable standards, ensuring high operational safety.
| Technical data | |
| 1- / 3-phase | 3 |
| Enclosure design | Switch cabinet |
| Output contacts | 2 C/O contacts |
| Width | 70 mm |
| Type | SP 9270CT |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 220 - 240 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | 10 - 100 A |
| Time delay | 0,1 - 20 s |
| Variant | 3-phase current relay with built in CT. De-energized on trip |
Questions & answers
What is the delivery time of Dold 0059428 SP9270.12CT overload relay AC220-240V 10-100A Tv=0.1-20S ?
The article Dold 0059428 SP9270.12CT overload relay AC220-240V 10-100A Tv=0.1-20S is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0059428 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0059428 SP9270.12CT overload relay AC220-240V 10-100A Tv=0.1-20S always at the best possible price. We can give you a discount of 2% on Dold 0059428 SP9270.12CT overload relay AC220-240V 10-100A Tv=0.1-20S if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 3 pieces of Dold 0059428 SP9270.12CT overload relay AC220-240V 10-100A Tv=0.1-20S we can offer you a price of 496,66 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.