Dold 0056004 BD9080.12/61 3AC480V UH AC480V phase monitor Tv=0.1-5s
|
415,11 EUR |
|||||||||||
|
( 493,98 EUR incl. VAT ) ≈ £347.45 | ≈ $456.21 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002092 | ||||||||||
| Mfg Part No: | 0056004 | ||||||||||
| UPC/EAN: | 4030641560041 | ||||||||||
| Weight: | 0.35 kg | ||||||||||
| Type: | BD9080.12/61 3AC480V UH AC480V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0056004:
Applications
The phase monitor is designed for monitoring three-phase networks with a nominal voltage of 3AC 480 V. It is particularly suitable for applications requiring stable and continuous power supply, such as in manufacturing industry, pump and fan systems, or power supply technology. The measurement ranges extend up to 750 V, with the standard measurement range being 3 AC 400 V. The device can monitor networks with or without a neutral conductor, enabling flexible integration into existing installations.
Functions and Equipment in Detail
The device detects voltage deviations within a range of 0.7 to 1.3 times the nominal voltage, with the range restricted to 0.8 to 1.1 times when the auxiliary voltage is drawn from the monitored network. Asymmetry detection occurs at voltage deviations of ±8 to ±20 % and a phase angle error of approximately 120° ±15°. The pickup delay is adjustable between 0.1 and 5 seconds, allowing adaptation to specific requirements. The reset delay is also 0.1 to 5 seconds to filter out short-term disturbances.
Technology Explained Simply
The phase monitor operates on the zero-current principle, where the output relay is not activated in the event of a fault. The output contacts consist of two changeover contacts, used for signal transmission to external switching devices or alarm systems. Power consumption is approximately 0.5 mA per phase (L1, L2) and 0.8 mA (L3) at nominal voltage. The auxiliary voltage is AC 480 V, with other voltages available upon request. The operating temperature range is -20 °C to +60 °C, with the same range for storage temperature.
Compatibility and Accessories
The device is designed for use in enclosures and has a width of 45 mm. The connection terminals are designated for phase voltages L1, L2, L3, as well as for auxiliary voltage A1/A2. The output contacts (11-12-14 and 21-22-24) allow connection to external relays or controls. Certifications include UL-rec. C/US, enabling use in specific markets.
Mounting and Installation
Mounting is performed in standard enclosures. The connection terminals are clearly labeled, with phases L1, L2, L3 and auxiliary voltage A1/A2 connected directly. LED indicators for auxiliary voltage, overvoltage, undervoltage, asymmetry/phase sequence/network failure, and contact position facilitate visual monitoring of the operating status. The device is designed for continuous operation and can be used up to an operating altitude of 2000 m.
Advantages in Operation
By detecting network disturbances early, the phase monitor enables preventive maintenance and thus prevents costly damage to connected devices. The adjustable pickup delay reduces false tripping due to short-term voltage fluctuations. The clear LED display supports rapid fault localization. The high mechanical life of at least 50 million switching operations and the electrical life of 250,000 switching operations at 1 A/AC 230 V ensure long service life. The short-circuit resistance, with a maximum fuse rating of 4 A gG/gL, increases safety in the event of a fault.
| Technical data | |
| 1- / 3-phase | 3 |
| Enclosure design | Switch cabinet |
| Measuring range max. | 750 V |
| Output contacts | 2 C/O contacts |
| Standard measuring range | 3 AC 400 V |
| Width | 45 mm |
| Type | BD 9080 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 480 V |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3AC 480 V |
| Release delay | 0,1 - 5 s |
| Approvals and Markings | UL-rec. C/US |
| Variant | De-Energized on trip |
Questions & answers
What is the delivery time of Dold 0056004 BD9080.12/61 3AC480V UH AC480V phase monitor Tv=0.1-5s?
The article Dold 0056004 BD9080.12/61 3AC480V UH AC480V phase monitor Tv=0.1-5s is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0056004 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0056004 BD9080.12/61 3AC480V UH AC480V phase monitor Tv=0.1-5s always at the best possible price. We can give you a discount of 2% on Dold 0056004 BD9080.12/61 3AC480V UH AC480V phase monitor Tv=0.1-5s if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0056004 BD9080.12/61 3AC480V UH AC480V phase monitor Tv=0.1-5s we can offer you a price of 396,43 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.