Further information for Dold 0056004 BD9080.12/61 3AC480V UH AC480V phase monitor
Technical data
1- / 3-phase
3
Enclosure design
Switch cabinet
Measuring range max.
750 V
Output contacts
2 C/O contacts
Standard measuring range
3 AC 400 V
Width
45 mm
Type
BD 9080
Operate delay
Variant
Auxiliary voltage
AC 480 V
Contact equipping
2 changeover contacts
Nominal voltage
3AC 480 V
Release delay
0,1 - 5 s
Approvals and Markings
UL-rec. C/US
Variant
De-Energized on trip
The phase monitor BD 9080 of the VARIMETER PRO series from Dold monitors three-phase networks for under- and overvoltage, asymmetry, phase failure, and incorrect phase sequence. The device is designed for use in industrial enclosures and ensures operational safety and availability of systems by early detection of network disturbances. Monitoring is performed in accordance with IEC/EN 60255-1, ensuring compliance with international standards for measuring and protective devices.
Applications
The phase monitor is designed for monitoring three-phase networks with a nominal voltage of 3AC 480 V. It is particularly suitable for applications requiring stable and continuous power supply, such as in manufacturing industry, pump and fan systems, or power supply technology. The measurement ranges extend up to 750 V, with the standard measurement range being 3 AC 400 V. The device can monitor networks with or without a neutral conductor, enabling flexible integration into existing installations.
Functions and Equipment in Detail
The device detects voltage deviations within a range of 0.7 to 1.3 times the nominal voltage, with the range restricted to 0.8 to 1.1 times when the auxiliary voltage is drawn from the monitored network. Asymmetry detection occurs at voltage deviations of ±8 to ±20 % and a phase angle error of approximately 120° ±15°. The pickup delay is adjustable between 0.1 and 5 seconds, allowing adaptation to specific requirements. The reset delay is also 0.1 to 5 seconds to filter out short-term disturbances.
Technology Explained Simply
The phase monitor operates on the zero-current principle, where the output relay is not activated in the event of a fault. The output contacts consist of two changeover contacts, used for signal transmission to external switching devices or alarm systems. Power consumption is approximately 0.5 mA per phase (L1, L2) and 0.8 mA (L3) at nominal voltage. The auxiliary voltage is AC 480 V, with other voltages available upon request. The operating temperature range is -20 °C to +60 °C, with the same range for storage temperature.
Compatibility and Accessories
The device is designed for use in enclosures and has a width of 45 mm. The connection terminals are designated for phase voltages L1, L2, L3, as well as for auxiliary voltage A1/A2. The output contacts (11-12-14 and 21-22-24) allow connection to external relays or controls. Certifications include UL-rec. C/US, enabling use in specific markets.
Mounting and Installation
Mounting is performed in standard enclosures. The connection terminals are clearly labeled, with phases L1, L2, L3 and auxiliary voltage A1/A2 connected directly. LED indicators for auxiliary voltage, overvoltage, undervoltage, asymmetry/phase sequence/network failure, and contact position facilitate visual monitoring of the operating status. The device is designed for continuous operation and can be used up to an operating altitude of 2000 m.
Advantages in Operation
By detecting network disturbances early, the phase monitor enables preventive maintenance and thus prevents costly damage to connected devices. The adjustable pickup delay reduces false tripping due to short-term voltage fluctuations. The clear LED display supports rapid fault localization. The high mechanical life of at least 50 million switching operations and the electrical life of 250,000 switching operations at 1 A/AC 230 V ensure long service life. The short-circuit resistance, with a maximum fuse rating of 4 A gG/gL, increases safety in the event of a fault.