Weight:0.073 kg
Type:IK9171.11/240 3/N AC400/230V 0,75UN
Graduated prices net
From piecesPrice per pieces
5109,52 EUR
10104,36 EUR
1599,20 EUR
2094,04 EUR

Product information for Dold 0055291:

The Dold undervoltage relay IK9171.11/240 is an electrical monitoring device for detecting undervoltages in three-phase networks. It is designed for use in 3-phase networks with neutral conductor connection, with a single-phase connection option also provided. The device operates on the no-current principle, whereby the output relay is not activated in the event of a fault, ensuring a safe and reliable response to voltage dips. The nominal voltage is 3/N AC 400/230 V, with a maximum nominal voltage reaching up to 3/N AC 500/290 V. The pickup value is fixed at 0.75 Un, meaning the relay responds when the voltage drops below 75% of the nominal voltage. The time delay t2 for resetting to the normal state is adjustable and ranges from 5 to 15 minutes. This delay is particularly useful in unstable networks, allowing certain consumer groups to be reconnected only after a defined waiting period following a brief power outage, for example to protect compressors or machining tools.

Applications

The relay is used for network monitoring, particularly in the field of safety power supply and safety lighting in accordance with DIN VDE 0100-710 and DIN VDE 0108. It is suitable for applications requiring automatic switching to a backup supply in the event of a voltage dip. The application is independent of phase sequence, enabling flexible installation. The device variant with time delay t2 is especially suitable for networks with local power generation or in regions with unstable power supplies, where a staged restart of consumers is necessary.

Functions and Equipment in Detail

The device features an output contact in the form of a changeover contact (1 changeover contact), which can be used to control auxiliary consumers or switching devices. The contact status is indicated by a yellow LED, which lights up when the output relay contact is closed (contacts 11-14). Measurement is performed using the arithmetic mean of the individual phases against the neutral conductor. For variants without neutral conductor connection, L1 and L3 are measured against L2 (IK/SK 9171) or L1 and L2 against L3 (IL/SL 9171). In single-phase operation, terminals L1, L2, and L3 must be bridged. The time delay t1 is only effective if the phase voltage L1-N (IK/SK 9171) or L3-N (IL/SL 9171) is at least 0.5 Un. Upon switching on the operating voltage, the device initially enters the normal state, even if a fault is present; the fault state is only activated after the time delay t1 has elapsed.

Technology Explained Simply

The relay continuously monitors the voltage in the network and responds when the defined pickup value of 0.75 Un is undershot. The time delay t2 ensures that after voltage restoration, not all consumers are switched back on immediately, but only after a defined waiting period. This prevents inrush currents and protects sensitive equipment. The hysteresis is approximately 4%, meaning the device only returns to the normal state when the voltage rises above the pickup value by 4%. The frequency range coverage is between 45 and 65 Hz, enabling use in various networks. The device requires no auxiliary voltage, simplifying installation and increasing reliability.

Compatibility and Accessories

The relay is designed for use in installation and industrial distributors in accordance with DIN 43 880. Type I (IK 9171) has a depth of 59 mm and bottom-mounted connection terminals. The width is 17.5 mm. It is compatible with various network voltages and can be used in both 3-phase and single-phase systems. The device variant is certified to IEC/EN 60255-1 and carries the UKCA mark.

Mounting and Installation

Mounting is carried out in installation or industrial distributors in accordance with DIN 43 880. The connection terminals are located at the bottom, enabling easy integration into existing switchgear. The width of 17.5 mm allows for compact placement. The terminals are designed for connection to cables, with the exact connection method shown in the device’s wiring diagram. Installation requires no additional tools, as the device operates without auxiliary voltage.

Operational Advantages

The relay provides reliable network monitoring without requiring additional power supply. The adjustable time delay t2 enables targeted control of consumer restart, increasing the lifespan of equipment. The LED indicator provides visual feedback on the operating status. Independence from phase sequence and compatibility with various network voltages increase installation flexibility. Certification to IEC/EN 60255-1 and the UKCA mark guarantee compliance with relevant safety and quality standards.
More spare projector bulbs for your Epson Beamer


Technical data
1- / 3-phase1, 3
Auxiliary voltageWithout
Enclosure designDistribution board
Nominal voltage max.3/N AC 500 / 290 V
Output contacts1 C/O contact
Width17,5 mm
TypeIK 9171
Operate delayYes
Variant
Contact equipping1 changeover contact
Nominal voltage3/N AC 400 / 230 V
Response value0,75 Un
Time delay5 - 15 min
Approvals and MarkingsUKCA
VariantWith N. NC circuit operation. Settable time delay t2. Fixed response value


Product data sheet
Datasheet for Dold 0055291, EAN: 4030641552916

Questions & answers

What is the delivery time of Dold 0055291 IK9171.11/240 3/N AC400/230V 0.75UN undervoltage relay Tv=5-15M?

The article Dold 0055291 IK9171.11/240 3/N AC400/230V 0.75UN undervoltage relay Tv=5-15M is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0055291 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0055291 IK9171.11/240 3/N AC400/230V 0.75UN undervoltage relay Tv=5-15M always at the best possible price. We can give you a discount of 2% on Dold 0055291 IK9171.11/240 3/N AC400/230V 0.75UN undervoltage relay Tv=5-15M if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0055291 IK9171.11/240 3/N AC400/230V 0.75UN undervoltage relay Tv=5-15M we can offer you a price of 109,52 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0055291 undervoltage relay 3/N AC400/230V 0,75UN
Dold 0055291 IK9171.11/240 3/N AC400/230V 0.75UN undervoltage relay Tv=5-15M
114,68 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0055291 undervoltage relay 3/N AC400/230V 0,75UN
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
1 + 7 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.