Dold 0053649 BA9054/010 AC50-500V UH AC/DC24-80V voltage relay Tv=0-20S
|
335,41 EUR |
|||||||||||
|
( 399,14 EUR incl. VAT ) ≈ £280.74 | ≈ $368.62 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1312787 | ||||||||||
| Mfg Part No: | 0053649 | ||||||||||
| UPC/EAN: | 4030641536497 | ||||||||||
| Weight: | 0.23 kg | ||||||||||
| Type: | BA9054/010 AC50-500V UH AC/DC24-80V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053649:
Applications
The relay is designed for monitoring voltages in the range of AC 50 to 500 V. It can be used both as an overvoltage relay and as an undervoltage relay, with the hysteresis depending on the set threshold value. The galvanic isolation between auxiliary circuit and measurement circuit ensures safe and interference-free measurement. The application is in enclosures, where the device is integrated with a width of 45 mm using standard rail mounting.
Functions and equipment in detail
The device features 2 changeover contacts as output contacts, which switch when the set threshold value is reached. The switching delay is 0 to 20 seconds and is activated when the set value is exceeded. The response delay is also integrated, preventing short-term voltage fluctuations from triggering an unwanted switching operation. The auxiliary voltage is supplied via AC/DC 24 to 80 V, enabling flexible integration into existing control systems.
Technology explained simply
The relay measures the arithmetic mean of the rectified measurement voltage. For AC voltages, the device is calibrated to the RMS value. The setting is performed via rotary switches, allowing both the pickup value and the drop-out value (hysteresis) to be adjusted. The LED indicators signal operational readiness (green LED) and activation of the output relay (yellow LED). The maximum rated voltage is AC 1000 V and DC 900 V, with measurement ranges varying depending on the variant. The maximum permissible continuous voltage for the AC 50–500 V measurement range is 500 V.
Compatibility and accessories
The relay complies with standards IEC/EN 60255-1 and IEC/EN 60947-1. It has UKCA and CCC certifications. The galvanic isolation between auxiliary and measurement circuits enables safe integration into electrical systems. The terminal connections are clearly labeled: A1/A2 for auxiliary voltage, e/f for voltage input, and contacts 11–14 and 21–24 for the two changeover contacts. The measurement frequency can reach up to 5 kHz, suitable for applications with rapid voltage changes.
Mounting and installation
The device is intended for mounting in enclosures and is installed using standard rail mounting (DIN rail). The width is 45 mm, allowing compact placement in existing control systems. The terminal connections are designed for secure connections, with the terminal labeling detailed in the data sheet. Installation requires no additional tools, with electrical connections to be made according to technical specifications.
Advantages in operation
By detecting voltage anomalies early, the relay enables preventive maintenance and prevents failures in electrical systems. The precise and reliable measurement ensures higher operational safety. The LED indicators facilitate diagnostics during operation, as the relay status can be visually monitored. The switching delay prevents false alarms caused by short-term voltage fluctuations, thereby increasing system stability. The high overload capacity of the device ensures robust performance under industrial conditions.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | AC 1000 V, DC 900 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9054 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC/DC 24 - 80 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 50 - 500 V |
| Start up delay | Without |
| Switching delay | 0 - 20 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overvoltage relay. Energized on trip. Time delay at setting value |
Questions & answers
What is the delivery time of Dold 0053649 BA9054/010 AC50-500V UH AC/DC24-80V voltage relay Tv=0-20S ?
The article Dold 0053649 BA9054/010 AC50-500V UH AC/DC24-80V voltage relay Tv=0-20S is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053649 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053649 BA9054/010 AC50-500V UH AC/DC24-80V voltage relay Tv=0-20S always at the best possible price. We can give you a discount of 2% on Dold 0053649 BA9054/010 AC50-500V UH AC/DC24-80V voltage relay Tv=0-20S if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053649 BA9054/010 AC50-500V UH AC/DC24-80V voltage relay Tv=0-20S we can offer you a price of 332,89 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.