Dold 0053647 BA9054/010 AC50-500V UH AC230V voltage relay Tv=0-20S
|
263,30 EUR |
|||||||||||
|
( 313,33 EUR incl. VAT ) ≈ £220.38 | ≈ $289.37 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1312786 | ||||||||||
| Mfg Part No: | 0053647 | ||||||||||
| UPC/EAN: | 4030641536473 | ||||||||||
| Weight: | 0.31 kg | ||||||||||
| Type: | BA9054/010 AC50-500V UH AC230V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053647:
Applications
This relay is suitable for voltage monitoring in industrial installations and railway applications. It monitors DC and AC voltages in the range of AC 50 to 500 V. Galvanic isolation between the auxiliary circuit and the measurement circuit ensures safe and interference-free measurement. Typical applications include systems requiring preventive maintenance and rapid fault localization to minimize downtime.
Functions and Equipment in Detail
The device features two changeover contacts as output contacts, which can be used to control external circuits. The switching delay is 0 to 20 seconds and is activated when the set threshold is exceeded. The pickup delay is also integrated, preventing unwanted switching due to short-term voltage fluctuations. The auxiliary voltage is AC 230 V, allowing seamless integration into standard industrial installations. The start-up bypass is not available in this variant.
Technology Explained Simply
The relay measures the arithmetic mean of the rectified measurement voltage. For AC voltages, the device is calibrated to the RMS value, enabling precise measurement even with sinusoidal voltages. Settings are adjusted via rotary switches, allowing manual adjustment of both the pickup value and the hysteresis value. The hysteresis depends on the set value and ensures the relay does not switch uncontrollably due to minor fluctuations around the threshold. LED indicators signal operational readiness (green LED) and activation of the output relay (yellow LED).
Compatibility and Accessories
The relay complies with standards IEC/EN 60255-1 and IEC/EN 60947-1. The maximum permissible continuous voltage is AC 1000 V and DC 900 V. The measurement frequency can reach up to 5 kHz, enabling use in systems with high frequencies. Galvanic isolation between the auxiliary and measurement circuits ensures safe and interference-free operation. The UKCA and CCC certifications are valid for this variant.
Mounting and Installation
The device is designed for mounting in enclosures and is connected via designated terminal clamps. Terminals A1 and A2 supply the auxiliary voltage of AC 230 V, while terminals e and f are designated for the voltage measurement input. The output contacts (11, 12, 14 and 21, 22, 24) enable control of external loads. Mounting is performed in the usual manner within an enclosure, taking into account the width of 45 mm.
Operational Advantages
Precise and reliable voltage monitoring enhances operational safety. Early detection of voltage anomalies enables preventive maintenance, preventing failures and damage to electrical equipment. LED indicators simplify diagnostics, as the operating status and contact position are visually identifiable. The switching delay prevents unwanted switching during short-term voltage fluctuations, increasing system stability. Galvanic isolation between the measurement and auxiliary circuits ensures high safety and immunity to interference.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | AC 1000 V, DC 900 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9054 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 230 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 50 - 500 V |
| Start up delay | Without |
| Switching delay | 0 - 20 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overvoltage relay. Energized on trip. Time delay at setting value |
Questions & answers
What is the delivery time of Dold 0053647 BA9054/010 AC50-500V UH AC230V voltage relay Tv=0-20S ?
The article Dold 0053647 BA9054/010 AC50-500V UH AC230V voltage relay Tv=0-20S is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053647 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053647 BA9054/010 AC50-500V UH AC230V voltage relay Tv=0-20S always at the best possible price. We can give you a discount of 2% on Dold 0053647 BA9054/010 AC50-500V UH AC230V voltage relay Tv=0-20S if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053647 BA9054/010 AC50-500V UH AC230V voltage relay Tv=0-20S we can offer you a price of 253,43 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.