Dold 0053641 BA9054/010 AC25-250V UH AC/DC24-80V voltage relay Tv=0-20s
|
325,64 EUR |
|||||||||||
|
( 387,51 EUR incl. VAT ) ≈ £272.56 | ≈ $357.88 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1152410 | ||||||||||
| Mfg Part No: | 0053641 | ||||||||||
| UPC/EAN: | 4030641536411 | ||||||||||
| Weight: | 0.23 kg | ||||||||||
| Type: | BA9054/010 AC25-250V UH AC/DC24-80V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053641:
Applications
This relay is designed for use in industrial plants and railway applications where reliable voltage monitoring is required. It protects electrical devices from destruction due to overvoltage and enables preventive maintenance by detecting voltage anomalies early. The application is in single-phase systems, and the devices can be used as both overvoltage and undervoltage relays, with hysteresis depending on the set value.
Functions and Equipment in Detail
The device features two changeover contacts as output contacts, which are galvanically isolated from the measurement circuit. LED indicators signal operational readiness (green LED) and activation of the output relay (yellow LED). Measurement is performed using the arithmetic mean of the rectified measurement voltage, with the devices calibrated for sinusoidal AC voltages in RMS value. The response delay is integrated, preventing reactions to short-term voltage spikes. The maximum rated voltage is AC 1000 V and DC 900 V.
Technology Explained Simply
Voltage monitoring is performed via inputs e and f, with the internal resistance varying depending on the measurement range. For the range AC 25 to 250 V, the internal resistance is 2 MΩ, and the maximum permissible continuous voltage is 500 V. The switching delay t_v delays switching after exceeding the threshold value, preventing false alarms caused by short-term voltage fluctuations. The start-up bypass is not present in this variant, meaning the device becomes active immediately upon applying the auxiliary voltage.
Compatibility and Accessories
The relay is compliant with IEC/EN 60255-1 and IEC/EN 60947-1 standards and carries the UKCA and CCC certifications. It is designed for measurement frequencies up to 5 kHz and can be used in systems with high overload capacity. The galvanic isolation between the auxiliary and measurement circuits ensures safe and interference-free signal transmission. The devices are designed for use in enclosures and can be combined with other components of the VARIMETER series.
Mounting and Installation
Mounting is performed in standard enclosures with a width of 45 mm. The connection terminals are clearly labeled: A1 and A2 for auxiliary voltage, e and f for voltage input, and contacts 11, 12, 14 and 21, 22, 24 for the two changeover contacts. Adjustment of threshold values and hysteresis is performed via rotary switches on the front. The devices are designed for use in industrial environments and require no additional mounting aids.
Advantages in Operation
Early detection of voltage anomalies enables preventive maintenance and reduces downtime. The LED indicators facilitate diagnosis and fault localization. Galvanic isolation and high overload capacity increase the reliability of the device. The switching delay prevents unnecessary switching operations during short-term voltage fluctuations, extending the service life of connected devices. The devices are suitable for use in industrial and railway applications where high operational safety is required.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | AC 1000 V, DC 900 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9054 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC/DC 24 - 80 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 25 - 250 V |
| Start up delay | Without |
| Switching delay | 0 - 20 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overvoltage relay. Energized on trip. Time delay at setting value |
Questions & answers
What is the delivery time of Dold 0053641 BA9054/010 AC25-250V UH AC/DC24-80V voltage relay Tv=0-20s?
The article Dold 0053641 BA9054/010 AC25-250V UH AC/DC24-80V voltage relay Tv=0-20s is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053641 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053641 BA9054/010 AC25-250V UH AC/DC24-80V voltage relay Tv=0-20s always at the best possible price. We can give you a discount of 2% on Dold 0053641 BA9054/010 AC25-250V UH AC/DC24-80V voltage relay Tv=0-20s if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053641 BA9054/010 AC25-250V UH AC/DC24-80V voltage relay Tv=0-20s we can offer you a price of 310,99 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.