Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm

Your rating:
Average rating
product review for Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm
( 4.6 / 5 ) 8 ratings
Dold 0053378
This image may differ from the desired article.
Dold 0053378Dold 0053378
251,89 EUR
( 299,75 EUR incl. VAT )
≈ £210.83  |  ≈ $276.83
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm
Datasheet:file_download Download
Lieske Part No.:799159
Mfg Part No: 0053378
UPC/EAN: 4030641533786
Weight:0.172 kg
Type:IL5880.12AC50-400HZ220-240V
Graduated prices net
From piecesPrice per pieces
4242,44 EUR
8233,00 EUR
12223,55 EUR
16214,11 EUR

Product information for Dold 0053378:

The insulation monitor IL5880.12AC50-400HZ220-240V from Dold is a device for monitoring insulation resistance in ungrounded pure alternating current and rotating current networks (IT systems) with a nominal voltage of AC 0 to 500 V. The device operates on the idle current principle, whereby the output relay does not activate in the event of a fault, but remains in the idle state. The auxiliary voltage is AC 220 to 240 V with a frequency of 50 to 400 Hz, enabling monitoring of de-energized systems as well. The width is 35 mm, and the device is designed for mounting in installation distributors according to DIN 43880. The housing design is configured as an installation distributor.

Applications

The insulation monitor is intended for pure alternating and rotating current networks with a voltage of 0 to 500 V and a frequency of 10 to 10000 Hz. It is particularly suitable for industrial and railway applications, as well as for monitoring de-energized consumers, for example, motor windings of devices that must be switched on in an emergency. The separate supply voltage enables monitoring even when the network is de-energized, which is important for mobile power generators or emergency power systems.

Functions and Equipment in Detail

The device features two changeover contacts as contact configuration, used for signal input into monitoring systems. The trip threshold for earth fault is adjustable and can be set via a potentiometer on the front of the device between 5 and 100 kΩ. The operational status is indicated by LEDs: a green LED indicates readiness for operation, while a red LED signals an insulation fault. The function of the output relays is programmable, allowing selection between memory and hysteresis behavior. The reset and test button on the device enables manual reset and testing of the status. Additionally, external reset and test buttons can be connected.

Technology Explained Simply

The insulation monitor monitors the resistance between the electrical network and earth. If the insulation resistance falls below the set alarm threshold of 5 to 100 kΩ, a fault is signaled. The galvanic isolation between the measurement circuit, auxiliary voltage, and output contacts ensures safe and interference-free measurement. The trip threshold setting is done via a potentiometer, making adaptation to different requirements simple and user-friendly. The LED indicators provide visual feedback on the operational status, enabling quick diagnosis.

Compatibility and Accessories

The device is specified according to IEC/EN 61557-8 and meets the requirements for monitoring IT systems. It is suitable for mounting in enclosures with mounting plates and cable ducts, as well as in installation distributors. Mounting is done either on DIN rails or by screws. The variant IL5880.12AC50-400HZ220-240V is supplied without a pre-warning threshold. Other variants of the series, such as IL/SL 5880/300, are available for mobile power generators according to DIN VDE 0100-551, but are not part of this version.

Mounting and Installation

Mounting is done in standard installation distributors with a depth of 61 mm and bottom-mounted connection terminals. The connection terminals are intended for connection to the monitored IT system, the protective conductor, and for external test and reset buttons. The DIN rail or screw mounting allows flexible integration into existing switchgear. The connection designations are described in detail in the data sheet.

Advantages in Operation

The insulation monitor provides preventive fire and system protection through early detection of insulation faults. The simple adjustment of the trip threshold and visual indication via LEDs simplify maintenance and diagnosis. The ability to monitor de-energized systems extends the application range in emergency power and mobile installations. The programmable function of the output relays allows flexible adaptation to different operational requirements.

Approvals and Markings

The device carries the UKCA and CCC approvals, confirming compliance with applicable safety and quality standards. Compliance with the standard IEC/EN 61557-8 ensures reliability and functionality in industrial use.

Functions and Features

The device is designed for monitoring IT systems with a nominal voltage of AC 0 to 500 V. The auxiliary voltage is AC 220 to 240 V at 50 to 400 Hz. The contact configuration includes two changeover contacts. The trip threshold is adjustable and ranges from 5 to 100 kΩ. Indication is provided via LEDs for operational readiness (green) and insulation fault (red). The function of the output relays is programmable, allowing selection between memory and hysteresis behavior. Mounting is in installation distributors with a width of 35 mm. Galvanic isolation between the measurement circuit, auxiliary voltage, and output contacts ensures safe measurement. The reset and test button enables manual reset and testing. External reset and test buttons can be connected. The device has UKCA and CCC approvals. The standard IEC/EN 61557-8 is complied with.

Technical data
Enclosure designDistribution board
IMD typeAC
Nominal voltage IT systemAC 0 - 500 V
Response value5 - 500 kΩ
Response value typeAdjustable
Width35 mm
TypeIL 5880
Earth fault indicatorYes
Variant
Alarm value5 - 100 kOhm
Auxiliary voltageAC 220 - 240 V 50 - 400 Hz
Contact equipping2 changeover contacts
Prewarning valueWithout
Approvals and MarkingsUKCA, CCC
VariantAdjustable alarm value. De-energized on trip


Product data sheet
Datasheet for Dold 0053378, EAN: 4030641533786

Questions & answers

What is the delivery time of Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm ?

The article Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053378 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm always at the best possible price. We can give you a discount of 2% on Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm we can offer you a price of 242,44 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0053378 insulation monitor 220-240V
Dold 0053378 IL5880.12 AC50-400Hz 220-240V insulation monitor 5-100 kOhm
251,89 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0053378 insulation monitor 220-240V
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
7 + 6 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.