Dold 0053350 BA9053/010 AC2,5-25A AC230V 0-20S current relay
|
263,30 EUR |
|||||||||||
|
( 313,33 EUR incl. VAT ) ≈ £220.38 | ≈ $289.37 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1312716 | ||||||||||
| Mfg Part No: | 0053350 | ||||||||||
| UPC/EAN: | 4030641533502 | ||||||||||
| Weight: | 0.31 kg | ||||||||||
| Type: | BA9053/010 AC2,5-25A AC230V 0-20S | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053350:
Applications
This relay is suitable for use in industrial plants, particularly in automation technology and railway operations. It monitors the current draw of electrical consumers, helping to prevent failures caused by overloads or malfunctions. Preventive maintenance is supported by the early detection of anomalies, enhancing operational safety and productivity. Galvanic isolation between the auxiliary circuit and the measurement circuit ensures safe and interference-free signal transmission.
Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which can be used to control auxiliary circuits or alarm systems. The measurement range is from AC 2.5 to 25 A, with the devices calibrated for sinusoidal AC currents in RMS value. Measurement is performed using the arithmetic mean of the rectified measurement current. The response delay is integrated, meaning the relay does not switch immediately upon exceeding the set value, but after a defined delay time. The hysteresis depends on the set value and can be adjusted via the front panel switches. LED indicators signal operational readiness (green LED) and activation of the output relay (yellow LED).
Technology Explained Simply
The relay technology is based on an internal shunt resistor that measures the current flow and converts it into a corresponding signal. The auxiliary voltage of AC 230 V powers the device and activates the output contacts. The switching delay t_v delays switching after exceeding the set value, which is useful for transient load peaks. The start-up bypass is not available in this variant, so no special suppression of inrush currents is provided. The devices comply with IEC/EN 60255-1 and IEC/EN 60947-1 standards, ensuring reliability and safety in industrial applications.
Compatibility and Accessories
The relay is designed for use in single-phase systems and can be used as both an overcurrent and undercurrent relay, with hysteresis consideration required for undercurrent applications. Galvanic isolation between the measurement and auxiliary circuits enables safe integration into existing systems. The devices are designed for a maximum measurement frequency of 5 kHz, suitable for applications with rapid signal changes. The UKCA and CCC certifications confirm compliance with applicable safety and quality standards.
Mounting and Installation
Mounting is performed in enclosures with a width of 45 mm. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, i/k for current input, and contacts 11-14 and 21-24 for the two changeover contacts. Adjustment of the response and hysteresis values is done via rotary switches on the front panel. The devices are designed for maximum overload capacity, with exact values varying depending on the measurement range. The connection terminals are designed for secure and durable connections.
Operational Advantages
Continuous current monitoring enables preventive maintenance, minimizing failures and downtime. The clear LED display facilitates diagnosis and fault localization. The switching delay prevents unnecessary tripping during short-term load peaks. Galvanic isolation ensures high immunity to interference and safety. Compliance with IEC/EN 60255-1 and IEC/EN 60947-1 standards guarantees reliable performance in critical applications. The compact design and simple operation make this relay a practical solution for industrial monitoring systems.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9053 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 230 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 2,5 - 25 A |
| Start up delay | Without |
| Switching delay | 0 - 20 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overcurrent relay. Energized on trip. Time delay at response value |
Questions & answers
What is the delivery time of Dold 0053350 BA9053/010 AC2,5-25A AC230V 0-20S current relay ?
The article Dold 0053350 BA9053/010 AC2,5-25A AC230V 0-20S current relay is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053350 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053350 BA9053/010 AC2,5-25A AC230V 0-20S current relay always at the best possible price. We can give you a discount of 2% on Dold 0053350 BA9053/010 AC2,5-25A AC230V 0-20S current relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053350 BA9053/010 AC2,5-25A AC230V 0-20S current relay we can offer you a price of 261,33 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.