Dold 0053210 BA9053/410 AC1A/5A/10A AC230V 0-20S current relay
|
279,93 EUR |
|||||||||||
|
( 333,12 EUR incl. VAT ) ≈ £234.30 | ≈ $307.64 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1312714 | ||||||||||
| Mfg Part No: | 0053210 | ||||||||||
| UPC/EAN: | 4030641532109 | ||||||||||
| Weight: | 0.31 kg | ||||||||||
| Type: | BA9053/410 AC1A/5A/10A AC230V 0-20S | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053210:
Applications
This relay is intended for use in industrial plants, machine controls, and railway systems where reliable current monitoring is required. It monitors the current consumption of motors, transformers, or other loads to prevent damage caused by overloading or interruptions. The device is installed in enclosures, with a width of 45 mm allowing compact mounting in standard control panels.
Functions and Features in Detail
The device offers three measurement ranges for AC current: 1 A, 5 A, and 10 A. Measurement is performed using the arithmetic mean of the rectified measurement current, with the devices calibrated for sinusoidal AC currents in RMS value. The pickup value and hysteresis are adjusted via rotary switches on the front of the device. The hysteresis depends on the set pickup value. The relay can be used as an overcurrent relay or an undercurrent relay, with switching delay activated when the set value is exceeded. The switching delay ranges from 0 to 20 seconds. The start-up bypass feature is not available in this variant.
Technology Explained Simply
Measurement is performed via an internal shunt resistor, which is dimensioned differently depending on the measurement range. The auxiliary voltage is AC 230 V, allowing the device to operate in standard low-voltage networks. The auxiliary circuit is galvanically separated from the measurement circuit, ensuring safe isolation between the measurement and control circuits. The measurement frequency can reach up to 5 kHz, enabling accurate detection of rapidly changing currents. The devices comply with IEC/EN 60255-1 and IEC/EN 60947-1.
Compatibility and Accessories
The relay is designed for use in single-phase systems. It features two changeover contacts (11-14 and 21-24), which can be used to control auxiliary circuits or alarm systems. Terminal markings follow A1/A2 for auxiliary voltage, i/k for current input, and 11-14 and 21-24 for output contacts. LED indicators (green for operational readiness, yellow for activated output relay) provide visual status indication.
Mounting and Installation
Mounting is performed in enclosures using screw fastening. The width of 45 mm corresponds to the standard for DIN rail mounting. Connection terminals are clearly labeled, ensuring error-free wiring. The devices are designed for maximum overload capacity, with maximum permissible currents varying according to the measurement range.
Operational Advantages
By detecting current deviations early, the relay enables preventive maintenance, minimizing downtime and increasing productivity. The LED indicators support rapid fault localization. The galvanic separation between the measurement and auxiliary circuits enhances operational safety. Compliance with standards IEC/EN 60255-1 and IEC/EN 60947-1, along with UKCA and CCC certifications, ensures suitability for various markets. The switching delay of 0 to 20 seconds allows for adjusted response to short-term current surges without triggering unnecessary shutdowns.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9053 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 230 V |
| Contact equipping | 1 changeover contact |
| Measuring range | AC 1 A/ 5 A/ 10 A |
| Start up delay | Without |
| Switching delay | 0 - 20 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overcurrent relay. Energized on trip. Time delay at response value. With 3 current ranges. 1 C/O contact |
Questions & answers
What is the delivery time of Dold 0053210 BA9053/410 AC1A/5A/10A AC230V 0-20S current relay ?
The article Dold 0053210 BA9053/410 AC1A/5A/10A AC230V 0-20S current relay is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053210 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053210 BA9053/410 AC1A/5A/10A AC230V 0-20S current relay always at the best possible price. We can give you a discount of 2% on Dold 0053210 BA9053/410 AC1A/5A/10A AC230V 0-20S current relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053210 BA9053/410 AC1A/5A/10A AC230V 0-20S current relay we can offer you a price of 277,83 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.