UPC/EAN: 4030641531287
Weight:0.31 kg
Type:BA9053/010 AC0,5-5A AC230V 0-20S
Graduated prices net
From piecesPrice per pieces
4253,43 EUR
8243,55 EUR
12233,68 EUR
16223,81 EUR

Product information for Dold 0053128:

The Dold current relay BA9053/010 is an overcurrent relay of the VARIMETER series, specifically designed for monitoring single-phase AC networks. It is used for continuous monitoring of the current consumption of electrical loads and enables preventive maintenance by detecting deviations early, thus avoiding failures in industrial installations. The device operates on the operating current principle and switches when the set current value is exceeded, with a switching delay of 0 to 20 seconds. Adjustment is made via rotary switches on the front of the device, allowing user-friendly and precise adaptation to the respective application.

Applications
The relay is designed for use in industrial and railway applications, where high operational safety and reliability are required. It monitors both DC and AC currents and is particularly suitable for detecting overloads in electrical systems, for example in motors, transformer installations, or process control. The galvanic isolation between auxiliary circuit and measuring circuit ensures safe and interference-free measurement, even under high disturbance voltages.

Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which can be used to control external circuits. The measuring range covers AC 0.5 to 5 A, with the measured value being captured as the arithmetic mean of the rectified current. The devices are calibrated for sinusoidal AC currents in RMS value. The response delay is integrated and ensures that the relay does not react immediately to short-term current peaks, but only after the set delay time has elapsed. This prevents unwanted switching off during normal inrush currents.

Technology Explained Simply
Current measurement is performed via an internal measuring resistor (shunt), which is adapted according to the measuring range. For this model, the internal resistance is 3 mΩ. The auxiliary voltage is AC 230 V, connected via terminals A1 and A2. Operational readiness is indicated by a green LED, while a yellow LED signals the status of the output relay. The switching delay activates after exceeding the set value, enabling controlled response to overloads. The hysteresis, i.e., the difference between pickup and drop-out value, depends on the set value and ensures stable switching behavior without oscillations.

Compatibility and Accessories
The relay is designed for installation in enclosures and has a width of 45 mm, making it suitable for standard switchboards. It is compliant with IEC/EN 60255-1 and IEC/EN 60947-1 standards and carries the approvals UKCA and CCC. The galvanic isolation between measuring and auxiliary circuit enables safe integration into existing installations. It can also be used as an undercurrent relay, where the switching delay activates after falling below the hysteresis value.

Mounting and Installation
Mounting is done in standard switchboards using rail mounting. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, i/k for current input, and contacts 11-14 and 21-24 for the two changeover contacts. Adjustment of pickup and hysteresis values is done via rotary switches on the front. The devices are designed for maximum overload capacity, with the maximum permissible current for 3 seconds being 800 mA (for the 0.5–5 A measuring range). The measuring frequency can reach up to 5 kHz, enabling use in systems with high frequencies.

Advantages in Operation
Through precise and reliable current monitoring, the relay supports preventive maintenance and enables faster fault localization. The integrated switching delay prevents unnecessary switching off during short-term load peaks. The clear LED indication facilitates diagnosis during operation. The device is designed for industrial environments and offers high operational safety through galvanic isolation and robust construction. Compliance with standards IEC/EN 60255-1 and IEC/EN 60947-1 ensures safe and standard-compliant integration into existing systems.

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Width45 mm
TypeBA 9053
Operate delayYes
Variant
Auxiliary voltageAC 230 V
Contact equipping2 changeover contacts
Measuring rangeAC 0,5 - 5 A
Start up delayWithout
Switching delay0 - 20 s
Approvals and MarkingsUKCA, CCC
VariantOvercurrent relay. Energized on trip. Time delay at response value


Product data sheet
Datasheet for Dold 0053128, EAN: 4030641531287

Questions & answers

What is the delivery time of Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay ?

The article Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053128 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay always at the best possible price. We can give you a discount of 2% on Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay we can offer you a price of 253,43 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0053128 current relay BA9053/010 AC0,5-5A AC230V
Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay
263,30 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0053128 current relay BA9053/010 AC0,5-5A AC230V
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
3 + 9 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.