Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay
|
263,30 EUR |
|||||||||||
|
( 313,33 EUR incl. VAT ) ≈ £220.38 | ≈ $289.37 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 951056 | ||||||||||
| Mfg Part No: | 0053128 | ||||||||||
| UPC/EAN: | 4030641531287 | ||||||||||
| Weight: | 0.31 kg | ||||||||||
| Type: | BA9053/010 AC0,5-5A AC230V 0-20S | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053128:
Applications
The relay is designed for use in industrial and railway applications, where high operational safety and reliability are required. It monitors both DC and AC currents and is particularly suitable for detecting overloads in electrical systems, for example in motors, transformer installations, or process control. The galvanic isolation between auxiliary circuit and measuring circuit ensures safe and interference-free measurement, even under high disturbance voltages.
Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which can be used to control external circuits. The measuring range covers AC 0.5 to 5 A, with the measured value being captured as the arithmetic mean of the rectified current. The devices are calibrated for sinusoidal AC currents in RMS value. The response delay is integrated and ensures that the relay does not react immediately to short-term current peaks, but only after the set delay time has elapsed. This prevents unwanted switching off during normal inrush currents.
Technology Explained Simply
Current measurement is performed via an internal measuring resistor (shunt), which is adapted according to the measuring range. For this model, the internal resistance is 3 mΩ. The auxiliary voltage is AC 230 V, connected via terminals A1 and A2. Operational readiness is indicated by a green LED, while a yellow LED signals the status of the output relay. The switching delay activates after exceeding the set value, enabling controlled response to overloads. The hysteresis, i.e., the difference between pickup and drop-out value, depends on the set value and ensures stable switching behavior without oscillations.
Compatibility and Accessories
The relay is designed for installation in enclosures and has a width of 45 mm, making it suitable for standard switchboards. It is compliant with IEC/EN 60255-1 and IEC/EN 60947-1 standards and carries the approvals UKCA and CCC. The galvanic isolation between measuring and auxiliary circuit enables safe integration into existing installations. It can also be used as an undercurrent relay, where the switching delay activates after falling below the hysteresis value.
Mounting and Installation
Mounting is done in standard switchboards using rail mounting. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, i/k for current input, and contacts 11-14 and 21-24 for the two changeover contacts. Adjustment of pickup and hysteresis values is done via rotary switches on the front. The devices are designed for maximum overload capacity, with the maximum permissible current for 3 seconds being 800 mA (for the 0.5–5 A measuring range). The measuring frequency can reach up to 5 kHz, enabling use in systems with high frequencies.
Advantages in Operation
Through precise and reliable current monitoring, the relay supports preventive maintenance and enables faster fault localization. The integrated switching delay prevents unnecessary switching off during short-term load peaks. The clear LED indication facilitates diagnosis during operation. The device is designed for industrial environments and offers high operational safety through galvanic isolation and robust construction. Compliance with standards IEC/EN 60255-1 and IEC/EN 60947-1 ensures safe and standard-compliant integration into existing systems.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9053 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 230 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 0,5 - 5 A |
| Start up delay | Without |
| Switching delay | 0 - 20 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overcurrent relay. Energized on trip. Time delay at response value |
Questions & answers
What is the delivery time of Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay ?
The article Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053128 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay always at the best possible price. We can give you a discount of 2% on Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053128 BA9053/010 AC0.5-5A AC230V 0-20S current relay we can offer you a price of 253,43 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.