Dold 0053121 BA9053/010 AC0.1-1A AC/DC80-230V current relay Tv=0-20s
|
325,64 EUR |
|||||||||||
|
( 387,51 EUR incl. VAT ) ≈ £272.56 | ≈ $357.88 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002246 | ||||||||||
| Mfg Part No: | 0053121 | ||||||||||
| UPC/EAN: | 4030641531218 | ||||||||||
| Weight: | 0.23 kg | ||||||||||
| Type: | BA9053/010 AC0,1-1A AC/DC80-230V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053121:
Applications
This relay is suitable for monitoring current consumption of electrical loads in industrial and railway applications. It can be used as an overcurrent relay or an undercurrent relay, with hysteresis depending on the set value. Galvanic isolation between the auxiliary circuit and the measurement circuit ensures high electrical safety. The measurement frequency is up to 5 kHz, enabling precise measurement even with rapid signal changes. The width of 45 mm allows for compact installation in enclosures.
Functions and Equipment in Detail
The relay features two changeover contacts as output contacts, which can be used to control external circuits. Adjustment is made via a rotary switch, allowing adjustment of the pickup value and dropout value (hysteresis). The LED indicator shows operational readiness (green LED) and activation of the output relay (yellow LED). The switching delay t_v delays switching after exceeding the set value, allowing short-term current peaks, such as those occurring during motor starts, to be ignored. The start-up bypass is not available in this variant.
Technology Explained Simply
The relay measures the arithmetic mean of the rectified measurement current. For AC current, the device is calibrated to the RMS value, enabling accurate measurement of sinusoidal currents. The internal measurement resistor (shunt) is designed for the measurement range AC 0.1 to 1 A. The maximum permissible continuous load is 0.7 A, with maximum current for 3 seconds (on) and 100 seconds (off) at 1.8 A. The devices comply with IEC/EN 60255-1 and IEC/EN 60947-1 standards and carry UKCA and CCC certifications.
Compatibility and Accessories
The relay is designed for use in enclosures and can be used in industrial installations to monitor motors, heaters, or other current-consuming devices. It is compatible with an auxiliary voltage of AC/DC 80 to 230 V and can be operated under various power supply conditions. Galvanic isolation between the measurement and auxiliary circuits ensures safe and interference-free operation.
Mounting and Installation
Mounting is done in an enclosure, with the width of 45 mm enabling compact placement. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, i/k for current measurement input, and contacts 11-14 and 21-24 for the two changeover contacts. Adjustment is made via the rotary switches on the front panel, requiring no additional tools.
Operational Advantages
Precise current measurement and configurable switching delay allow the relay to ignore disturbances caused by short-term current peaks and respond only to sustained overloads. The LED indicator enables quick visual inspection of the operating status. Galvanic isolation increases safety, and compliance with IEC/EN 60255-1 and IEC/EN 60947-1 standards ensures reliable performance in industrial environments. Early fault detection supports preventive maintenance, increasing productivity and minimizing downtime.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9053 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC/DC 80 - 230 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 0,1 - 1 A |
| Start up delay | Without |
| Switching delay | 0 - 20 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overcurrent relay. Energized on trip. Time delay at response value |
Questions & answers
What is the delivery time of Dold 0053121 BA9053/010 AC0.1-1A AC/DC80-230V current relay Tv=0-20s?
The article Dold 0053121 BA9053/010 AC0.1-1A AC/DC80-230V current relay Tv=0-20s is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053121 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053121 BA9053/010 AC0.1-1A AC/DC80-230V current relay Tv=0-20s always at the best possible price. We can give you a discount of 2% on Dold 0053121 BA9053/010 AC0.1-1A AC/DC80-230V current relay Tv=0-20s if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053121 BA9053/010 AC0.1-1A AC/DC80-230V current relay Tv=0-20s we can offer you a price of 310,99 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.