Dold 0053121, EAN: 4030641531218

Dold 0053121 current relay AC0,1-1A AC/DC80-230V

Dold 0053121 current relay AC0,1-1A AC/DC80-230V

Lieske Part No. 1002246
Mfg Part No 0053121
EAN-Code 4030641531218
Manufacturer Dold
Here only 325,64 EUR
387,51 EUR incl. VAT

Further information for Dold 0053121 current relay AC0,1-1A AC/DC80-230V

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Width45 mm
TypeBA 9053
Operate delayYes
Variant
Auxiliary voltageAC/DC 80 - 230 V
Contact equipping2 changeover contacts
Measuring rangeAC 0,1 - 1 A
Start up delayWithout
Switching delay0 - 20 s
Approvals and MarkingsUKCA, CCC
VariantOvercurrent relay. Energized on trip. Time delay at response value
The Dold current relay BA9053/010 AC0,1-1A AC/DC80-230V is an industrial overcurrent relay from the VARIMETER series, designed for continuous monitoring of single-phase DC and AC power networks. It enables early detection of current overloads, allowing for preventive maintenance of electrical systems to avoid failures and enhance operational safety. Device settings are adjusted via rotary switches on the front panel, ensuring simple and user-friendly configuration. The relay operates on the operating current principle and switches when the set current value is exceeded, with a switching delay of 0 to 20 seconds. The auxiliary voltage is AC/DC 80 to 230 V, enabling flexible use in various power supply conditions.

Applications
This relay is suitable for monitoring current consumption of electrical loads in industrial and railway applications. It can be used as an overcurrent relay or an undercurrent relay, with hysteresis depending on the set value. Galvanic isolation between the auxiliary circuit and the measurement circuit ensures high electrical safety. The measurement frequency is up to 5 kHz, enabling precise measurement even with rapid signal changes. The width of 45 mm allows for compact installation in enclosures.

Functions and Equipment in Detail
The relay features two changeover contacts as output contacts, which can be used to control external circuits. Adjustment is made via a rotary switch, allowing adjustment of the pickup value and dropout value (hysteresis). The LED indicator shows operational readiness (green LED) and activation of the output relay (yellow LED). The switching delay t_v delays switching after exceeding the set value, allowing short-term current peaks, such as those occurring during motor starts, to be ignored. The start-up bypass is not available in this variant.

Technology Explained Simply
The relay measures the arithmetic mean of the rectified measurement current. For AC current, the device is calibrated to the RMS value, enabling accurate measurement of sinusoidal currents. The internal measurement resistor (shunt) is designed for the measurement range AC 0.1 to 1 A. The maximum permissible continuous load is 0.7 A, with maximum current for 3 seconds (on) and 100 seconds (off) at 1.8 A. The devices comply with IEC/EN 60255-1 and IEC/EN 60947-1 standards and carry UKCA and CCC certifications.

Compatibility and Accessories
The relay is designed for use in enclosures and can be used in industrial installations to monitor motors, heaters, or other current-consuming devices. It is compatible with an auxiliary voltage of AC/DC 80 to 230 V and can be operated under various power supply conditions. Galvanic isolation between the measurement and auxiliary circuits ensures safe and interference-free operation.

Mounting and Installation
Mounting is done in an enclosure, with the width of 45 mm enabling compact placement. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, i/k for current measurement input, and contacts 11-14 and 21-24 for the two changeover contacts. Adjustment is made via the rotary switches on the front panel, requiring no additional tools.

Operational Advantages
Precise current measurement and configurable switching delay allow the relay to ignore disturbances caused by short-term current peaks and respond only to sustained overloads. The LED indicator enables quick visual inspection of the operating status. Galvanic isolation increases safety, and compliance with IEC/EN 60255-1 and IEC/EN 60947-1 standards ensures reliable performance in industrial environments. Early fault detection supports preventive maintenance, increasing productivity and minimizing downtime.
This is an offer of: