Dold 0053116 BA9053/010 AC0.1-1A AC230V 0-20S current relay
|
263,30 EUR |
|||||||||||
|
( 313,33 EUR incl. VAT ) ≈ £220.38 | ≈ $289.37 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 277311 | ||||||||||
| Mfg Part No: | 0053116 | ||||||||||
| UPC/EAN: | 4030641531164 | ||||||||||
| Weight: | 0.31 kg | ||||||||||
| Type: | BA9053/010 AC0,1-1A AC230V 0-20S | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053116:
Applications
This relay is suitable for industrial applications as well as railway applications. It monitors current consumption in electrical systems to prevent failures caused by overloading or underloading. Early detection of faults supports preventive maintenance and increases operational safety. The relay is installed in enclosures, with a width of 45 mm, making it suitable for standard control panels.
Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which are galvanically isolated from the measuring circuit. The auxiliary voltage is AC 230 V, ensuring safe and reliable power supply for the auxiliary circuit. The measuring ranges are designed for AC 0.1 to 1 A, with the devices calibrated for sinusoidal AC currents in RMS value. Measurement is performed using the arithmetic mean of the rectified measuring current. The switching delay is 0 to 20 seconds, meaning switching is delayed after exceeding the set value. The pickup delay is active, meaning the relay does not switch immediately upon reaching the pickup value, but incorporates a short delay.
Technology Explained Simply
The relay technology is based on an internal measuring resistor (shunt) that converts the measuring current into a measurable voltage signal. The measuring frequency can reach up to 5 kHz, enabling accurate detection even with rapidly changing currents. The galvanic isolation between the auxiliary and measuring circuits protects the control electronics from disturbances caused by the measuring current. LED indicators signal the operating status: a green LED lights up when auxiliary voltage is applied, and a yellow LED when the output relay is activated. This visual feedback facilitates diagnosis during operation.
Compatibility and Accessories
The relay is designed for use in single-phase systems and can be combined with other VARIMETER models. It complies with the standards IEC/EN 60255-1 and IEC/EN 60947-1. The certifications UKCA and CCC confirm compliance with respective safety and quality standards. The devices are designed for high overload capacity, with the maximum permissible continuous current varying depending on the measuring range. The start-up bypass is not included in this variant, meaning the relay does not automatically bypass the inrush current during start-up.
Mounting and Installation
Mounting is performed in enclosures, with the width of 45 mm ensuring compatibility with standard control panels. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, i/k for current input, and contacts 11-14 and 21-24 for the two changeover contacts. Installation requires no special tools, as adjustments are made via rotary switches on the front panel.
Advantages in Operation
Precise and reliable measurement enables quick fault localization and reduces downtime of systems. The switching delay prevents unwanted tripping during short-term current peaks, while the pickup delay ensures stable response to slow current changes. The LED indicators provide visual feedback, facilitating maintenance and diagnosis during operation. Galvanic isolation increases safety and prevents disturbances in the control circuit.
Certifications and Markings
The device carries the certifications UKCA and CCC, confirming compliance with respective safety and quality requirements. The standards IEC/EN 60255-1 and IEC/EN 60947-1 define technical requirements for measuring and protective devices, which this relay meets. Manufacturer specifications refer to the technical status at the time of publication, with technical improvements possible at any time.
| Technical data | |
| 1- / 3-phase | 1 |
| Enclosure design | Switch cabinet |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9053 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 230 V |
| Contact equipping | 2 changeover contacts |
| Measuring range | AC 0,1 - 1 A |
| Start up delay | Without |
| Switching delay | 0 - 20 s |
| Approvals and Markings | UKCA, CCC |
| Variant | Overcurrent relay. Energized on trip. Time delay at response value |
Questions & answers
What is the delivery time of Dold 0053116 BA9053/010 AC0.1-1A AC230V 0-20S current relay ?
The article Dold 0053116 BA9053/010 AC0.1-1A AC230V 0-20S current relay is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053116 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053116 BA9053/010 AC0.1-1A AC230V 0-20S current relay always at the best possible price. We can give you a discount of 2% on Dold 0053116 BA9053/010 AC0.1-1A AC230V 0-20S current relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0053116 BA9053/010 AC0.1-1A AC230V 0-20S current relay we can offer you a price of 253,43 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.