Dold 0053116, EAN: 4030641531164

Dold 0053116 current relay BA9053/010 AC230V

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0053116 current relay BA9053/010 AC230V

Lieske Part No. 277311
Mfg Part No 0053116
EAN-Code 4030641531164
Manufacturer Dold
Here only 263,30 EUR
313,33 EUR incl. VAT

Further information for Dold 0053116 current relay BA9053/010 AC230V

Technical data
1- / 3-phase1
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Width45 mm
TypeBA 9053
Operate delayYes
Variant
Auxiliary voltageAC 230 V
Contact equipping2 changeover contacts
Measuring rangeAC 0,1 - 1 A
Start up delayWithout
Switching delay0 - 20 s
Approvals and MarkingsUKCA, CCC
VariantOvercurrent relay. Energized on trip. Time delay at response value
The Dold current relay BA9053/010 is an overcurrent relay of the VARIMETER series, designed for monitoring single-phase DC and AC power networks. It is used for continuous measurement and monitoring of the current consumption of electrical loads, enabling early detection of deviations from the setpoint. The device setting is adjusted via rotary switches on the front panel, allowing for simple and user-friendly adjustment of the pickup and drop-out values. The function is based on the operating current principle, whereby the relay operates as an overcurrent relay but can also be used as an undercurrent relay. The hysteresis depends on the set pickup value, enabling precise switching behavior.

Applications
This relay is suitable for industrial applications as well as railway applications. It monitors current consumption in electrical systems to prevent failures caused by overloading or underloading. Early detection of faults supports preventive maintenance and increases operational safety. The relay is installed in enclosures, with a width of 45 mm, making it suitable for standard control panels.

Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which are galvanically isolated from the measuring circuit. The auxiliary voltage is AC 230 V, ensuring safe and reliable power supply for the auxiliary circuit. The measuring ranges are designed for AC 0.1 to 1 A, with the devices calibrated for sinusoidal AC currents in RMS value. Measurement is performed using the arithmetic mean of the rectified measuring current. The switching delay is 0 to 20 seconds, meaning switching is delayed after exceeding the set value. The pickup delay is active, meaning the relay does not switch immediately upon reaching the pickup value, but incorporates a short delay.

Technology Explained Simply
The relay technology is based on an internal measuring resistor (shunt) that converts the measuring current into a measurable voltage signal. The measuring frequency can reach up to 5 kHz, enabling accurate detection even with rapidly changing currents. The galvanic isolation between the auxiliary and measuring circuits protects the control electronics from disturbances caused by the measuring current. LED indicators signal the operating status: a green LED lights up when auxiliary voltage is applied, and a yellow LED when the output relay is activated. This visual feedback facilitates diagnosis during operation.

Compatibility and Accessories
The relay is designed for use in single-phase systems and can be combined with other VARIMETER models. It complies with the standards IEC/EN 60255-1 and IEC/EN 60947-1. The certifications UKCA and CCC confirm compliance with respective safety and quality standards. The devices are designed for high overload capacity, with the maximum permissible continuous current varying depending on the measuring range. The start-up bypass is not included in this variant, meaning the relay does not automatically bypass the inrush current during start-up.

Mounting and Installation
Mounting is performed in enclosures, with the width of 45 mm ensuring compatibility with standard control panels. The connection terminals are clearly labeled: A1/A2 for auxiliary voltage, i/k for current input, and contacts 11-14 and 21-24 for the two changeover contacts. Installation requires no special tools, as adjustments are made via rotary switches on the front panel.

Advantages in Operation
Precise and reliable measurement enables quick fault localization and reduces downtime of systems. The switching delay prevents unwanted tripping during short-term current peaks, while the pickup delay ensures stable response to slow current changes. The LED indicators provide visual feedback, facilitating maintenance and diagnosis during operation. Galvanic isolation increases safety and prevents disturbances in the control circuit.

Certifications and Markings
The device carries the certifications UKCA and CCC, confirming compliance with respective safety and quality requirements. The standards IEC/EN 60255-1 and IEC/EN 60947-1 define technical requirements for measuring and protective devices, which this relay meets. Manufacturer specifications refer to the technical status at the time of publication, with technical improvements possible at any time.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter: