Dold 0053088 IL9086.38/100 3AC 50/60 Hz 230/400 V phase monitor
|
194,29 EUR |
|||||||||||
|
( 231,21 EUR incl. VAT ) ≈ £162.62 | ≈ $213.52 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 531403 | ||||||||||
| Mfg Part No: | 0053088 | ||||||||||
| UPC/EAN: | 4030641530884 | ||||||||||
| Weight: | 0.197 kg | ||||||||||
| Type: | IL9086.38/100 | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0053088:
Applications
The phase monitor is designed for monitoring three-phase three-wire and four-wire systems. It detects various network faults, including undervoltage, phase failure, incorrect phase sequence, neutral conductor interruption, and network asymmetry. Additionally, the device monitors motor temperature via a PTC input, designed for up to six series-connected thermistors. The application is particularly in systems with motor loads, where reliable operational monitoring is required.
Functions and equipment in detail
The device features two independent output relays, each with a single changeover contact. The first contact (11-12-14) responds to temperature faults, the second (21-22-24) to network faults. The contacts are made of AgNi and are rated for switching capacities up to 1250 VA. Temperature monitoring is performed via a galvanically isolated PTC input (P1-P2), which triggers at a resistance value of 3.2 to 3.8 kΩ and resets at 1.5 to 1.8 kΩ. A short circuit in the sensor circuit is detected at a resistance of 10 to 30 Ω, and an open circuit is detected at a resistance above 3.8 kΩ. The measurement voltage at the PTC input is a maximum of 2 V at a resistance of 1.5 kΩ.
Technology explained simply
The device operates without auxiliary voltage and draws its operating voltage directly from the monitored network. The nominal voltage is 3AC 230/400 V, with a voltage range between 0.8 and 1.1 times nominal voltage. Undervoltage detection occurs at approximately 0.7 times nominal voltage. The response delay is 100 to 300 ms, and the switch-on delay is 15 to 30 ms. Asymmetry detection occurs at an angular asymmetry of approximately 20°. The hysteresis is a maximum of 6 % of nominal voltage. The LED indicators signal the operating status: the left LED indicates correct operating voltage, the right LED indicates correct measurement voltage, and the middle LED (ϑ) indicates correct motor temperature. In fault-free operation, all three LEDs are illuminated.
Compatibility and accessories
The device is designed for 3-phase systems and can be used in both three-wire and four-wire systems. When used in a three-wire system, the neutral conductor connection remains open. Temperature monitoring is performed via PTC sensors according to DIN 44081/44082. The number of connected thermistors can range from 1 to 6. The measurement circuit load is less than 5 mW at a resistance of 1.5 kΩ. The relay switching voltage is between 10 V and 250 V AC or 120 V DC, and the switching current is between 0.1 A and 5 A.
Mounting and installation
The device is mounted in installation distributors according to DIN 43 880. The depth is 59 mm and the width is 35 mm. The connection terminals are located at the bottom. Mounting is done in standard 35 mm mounting rails. The connections for the network voltage (L1, L2, L3, N) and the PTC input (P1, P2) are clearly marked. The relay outputs (11-12-14, 21-22-24) are intended for connection to external control or switching devices.
Advantages in operation
The phase monitor provides reliable, maintenance-free monitoring of network and temperature conditions without auxiliary voltage. The LED indicators enable quick visual fault diagnosis. The galvanic isolation of the PTC input increases safety. The integrated fault memory function for temperature rise or short circuit in the sensor circuit allows manual reset via a RESET button. The high electrical life of 600,000 switching cycles at 1 A and AC 230 V ensures long service life. Compliance with standards IEC/EN 60255-1 and IEC/EN 60947-8 ensures conformity with applicable safety standards.
| Technical data | |
| 1- / 3-phase | 3 |
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Measuring range max. | 400 V |
| Output contacts | 2 x 1 C/O contacts |
| Standard measuring range | 3/N AC 400/230 V |
| Width | 35 mm |
| Type | IL 9086 |
| Variant | |
| Contact equipping | 2 x 1 changeover contact |
| Nominal voltage | 3AC 230/400 V |
| Variant | De-energized on trip. With manual reset after detection of overtemperature or short circuit in the sensor circuit |
Questions & answers
What is the delivery time of Dold 0053088 IL9086.38/100 3AC 50/60 Hz 230/400 V phase monitor ?
The article Dold 0053088 IL9086.38/100 3AC 50/60 Hz 230/400 V phase monitor is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0053088 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0053088 IL9086.38/100 3AC 50/60 Hz 230/400 V phase monitor always at the best possible price. We can give you a discount of 2% on Dold 0053088 IL9086.38/100 3AC 50/60 Hz 230/400 V phase monitor if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0053088 IL9086.38/100 3AC 50/60 Hz 230/400 V phase monitor we can offer you a price of 192,83 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.