Dold 0053088, EAN: 4030641530884

Dold 0053088 IL9086.38/100 phase monitor 3AC 230/400 V

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0053088 IL9086.38/100 phase monitor 3AC 230/400 V

Lieske Part No. 531403
Mfg Part No 0053088
EAN-Code 4030641530884
Manufacturer Dold
Here only 194,29 EUR
231,21 EUR incl. VAT

Further information for Dold 0053088 IL9086.38/100 phase monitor 3AC 230/400 V

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designDistribution board
Measuring range max.400 V
Output contacts2 x 1 C/O contacts
Standard measuring range3/N AC 400/230 V
Width35 mm
TypeIL 9086
Variant
Contact equipping2 x 1 changeover contact
Nominal voltage3AC 230/400 V
VariantDe-energized on trip. With manual reset after detection of overtemperature or short circuit in the sensor circuit
The Dold IL9086.38/100 is a phase monitor for monitoring three-phase networks with motor loads, as well as for temperature monitoring of connected motors, for example in elevator systems. The device operates on the no-load current principle, in which the output relays do not activate in the event of a fault, but instead open their contacts. It is designed for use in installation and industrial distributors according to DIN 43 880 and has a width of 35 mm. The IL 9086 design has a depth of 59 mm and is equipped with bottom-mounted connection terminals.

Applications

The phase monitor is designed for monitoring three-phase three-wire and four-wire systems. It detects various network faults, including undervoltage, phase failure, incorrect phase sequence, neutral conductor interruption, and network asymmetry. Additionally, the device monitors motor temperature via a PTC input, designed for up to six series-connected thermistors. The application is particularly in systems with motor loads, where reliable operational monitoring is required.

Functions and equipment in detail

The device features two independent output relays, each with a single changeover contact. The first contact (11-12-14) responds to temperature faults, the second (21-22-24) to network faults. The contacts are made of AgNi and are rated for switching capacities up to 1250 VA. Temperature monitoring is performed via a galvanically isolated PTC input (P1-P2), which triggers at a resistance value of 3.2 to 3.8 kΩ and resets at 1.5 to 1.8 kΩ. A short circuit in the sensor circuit is detected at a resistance of 10 to 30 Ω, and an open circuit is detected at a resistance above 3.8 kΩ. The measurement voltage at the PTC input is a maximum of 2 V at a resistance of 1.5 kΩ.

Technology explained simply

The device operates without auxiliary voltage and draws its operating voltage directly from the monitored network. The nominal voltage is 3AC 230/400 V, with a voltage range between 0.8 and 1.1 times nominal voltage. Undervoltage detection occurs at approximately 0.7 times nominal voltage. The response delay is 100 to 300 ms, and the switch-on delay is 15 to 30 ms. Asymmetry detection occurs at an angular asymmetry of approximately 20°. The hysteresis is a maximum of 6 % of nominal voltage. The LED indicators signal the operating status: the left LED indicates correct operating voltage, the right LED indicates correct measurement voltage, and the middle LED (ϑ) indicates correct motor temperature. In fault-free operation, all three LEDs are illuminated.

Compatibility and accessories

The device is designed for 3-phase systems and can be used in both three-wire and four-wire systems. When used in a three-wire system, the neutral conductor connection remains open. Temperature monitoring is performed via PTC sensors according to DIN 44081/44082. The number of connected thermistors can range from 1 to 6. The measurement circuit load is less than 5 mW at a resistance of 1.5 kΩ. The relay switching voltage is between 10 V and 250 V AC or 120 V DC, and the switching current is between 0.1 A and 5 A.

Mounting and installation

The device is mounted in installation distributors according to DIN 43 880. The depth is 59 mm and the width is 35 mm. The connection terminals are located at the bottom. Mounting is done in standard 35 mm mounting rails. The connections for the network voltage (L1, L2, L3, N) and the PTC input (P1, P2) are clearly marked. The relay outputs (11-12-14, 21-22-24) are intended for connection to external control or switching devices.

Advantages in operation

The phase monitor provides reliable, maintenance-free monitoring of network and temperature conditions without auxiliary voltage. The LED indicators enable quick visual fault diagnosis. The galvanic isolation of the PTC input increases safety. The integrated fault memory function for temperature rise or short circuit in the sensor circuit allows manual reset via a RESET button. The high electrical life of 600,000 switching cycles at 1 A and AC 230 V ensures long service life. Compliance with standards IEC/EN 60255-1 and IEC/EN 60947-8 ensures conformity with applicable safety standards.