Dold 0052577 BH9251.11 AC230V 50/60Hz 20A semiconductor contactor with current monitoring
|
481,64 EUR |
|||||||||||
|
( 573,15 EUR incl. VAT ) ≈ £403.13 | ≈ $529.32 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 760149 | ||||||||||
| Mfg Part No: | 0052577 | ||||||||||
| UPC/EAN: | 4030641525774 | ||||||||||
| Weight: | 0.675 kg | ||||||||||
| Type: | BH9251.11AC230V50/60HZ20A | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0052577:
Applications
This contactor is designed for use in systems with parallel arrangement of heating cartridges, where up to 12 heating cartridges can be connected. At a load voltage of AC 230 V, the maximum total power of the connected heating cartridges is 4600 W, with each individual cartridge having a power of up to 380 W. The application is in continuously operating machines where high reliability and precise current monitoring are required. The devices are designed for use in environments with an operating temperature of 0 to +40 °C, with the maximum device temperature being 60 °C; if exceeded, the load current is reduced.
Functions and Equipment in Detail
The device features integrated current monitoring, detecting undercurrent, overcurrent, and interruptions in the load circuit. Temperature monitoring protects the power semiconductor from overheating. In the event of a fault, the output relay is deactivated according to the zero-current principle to prevent incorrect control. An alarm relay with 1 changeover contact serves as a signal output for fault indications. The current pickup value is adjustable continuously within the measurement range. The evaluation time is maximum 100 ms, enabling a rapid response to load changes. The LEDs serve as status indicators, signaling whether the mains voltage is present and whether the setpoint and load current match.
Technology Explained Simply
The contactor operates according to the zero-voltage switching principle, ensuring switching operations occur at voltage zero crossings to minimize arcing and interference. Compensation for voltage fluctuations of ±20 % ensures stable operation even with irregular mains voltage. The load voltage is AC 230 V ±20 %, and the blocking voltage is 1200 Vp. Switching delay is limited to under 100 ms. The integrated heatsink ensures efficient heat dissipation. The electrical life expectancy is at least 200,000 switching operations at 3 A and AC 230 V, and the mechanical life expectancy is at least 1,000,000 switching operations.
Compatibility and Accessories
The device is designed for mounting on DIN rail and can be used in enclosures with standard widths of 45 mm, 67.5 mm, and 112.5 mm. Compatibility with other devices is ensured by standards IEC/EN 60947-1 and IEC/EN 60947-4-2. Maximum short-circuit withstand is achieved with a maximum fuse rating of 4 A gG/gL. Creepage and clearance distances correspond to pollution degree 2 with a rated impulse withstand voltage of 4 kV.
Mounting and Installation
Mounting is done by clipping onto a DIN rail. The connection terminals are designed for connection with cables. Control is via input X1-X2, with a pulse duration of at least 100 ms required. The terminal assignment is detailed in the datasheet. Installation is to be carried out in a closed enclosure, with the operating altitude below 2000 m.
Advantages in Operation
The contactor offers high reliability through integrated current and temperature monitoring. Galvanic isolation of the control input increases safety. Fault tolerance through voltage fluctuation compensation and fast response time ensures stable operation. LED indicators enable quick diagnosis of operating status. Mounting on DIN rail and compact design facilitate integration into existing systems.
| Technical data | |
| Load current up to | 40 A |
| Load voltage up to | AC 400 V |
| Number of poles | 1-pole |
| On/Off Input Control | AC/DC |
| Width | 45 mm, 67,5 mm, 112,5 mm |
| Type | BH 9251 |
| Signalling output | |
| Temperature monitoring | |
| Variant | |
| Contact equipping | 1 changeover contact |
| Load current | 20 A |
| Nominal voltage | AC 230 V |
Questions & answers
What is the delivery time of Dold 0052577 BH9251.11 AC230V 50/60Hz 20A semiconductor contactor with current monitoring ?
The article Dold 0052577 BH9251.11 AC230V 50/60Hz 20A semiconductor contactor with current monitoring is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0052577 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0052577 BH9251.11 AC230V 50/60Hz 20A semiconductor contactor with current monitoring always at the best possible price. We can give you a discount of 2% on Dold 0052577 BH9251.11 AC230V 50/60Hz 20A semiconductor contactor with current monitoring if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0052577 BH9251.11 AC230V 50/60Hz 20A semiconductor contactor with current monitoring we can offer you a price of 474,42 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.