Applications
This relay is used in industrial and commercial facilities where reliable network monitoring is required. It protects sensitive loads from damage caused by sudden voltage drops or phase failures. Typical applications include monitoring power supplies in production plants, lighting systems, emergency power supplies, and installations certified to DIN VDE 0108. The variant with time delay t1 is particularly suitable for unstable networks, for example, in local power generation or in networks with high load, where delayed fault signaling prevents unnecessary disconnection of loads during brief voltage dips.
Functions and Features in Detail
The device detects undervoltages in three-phase networks and can also be connected single-phase, in which case terminals L1, L2, and L3 must be bridged. Measurement is performed via the arithmetic mean of the phase voltages; for variants without neutral conductor connection, L1 and L3 are measured against L2 (IK/SK 9171) or L1 and L2 against L3 (IL/SL 9171). The LED indicator signals the state of the output relay – the yellow LED lights up when the contact is activated. Phase sequence is arbitrary, which enhances installation flexibility. The hysteresis is approximately 4 %, ensuring stable switching behavior.
Technology Explained Simply
The relay operates without auxiliary voltage, meaning it is directly connected to the network to be monitored and draws its power from it. The standby current principle ensures that the output relay is not activated under normal conditions – it only switches when a fault is detected. The time delay t1 prevents immediate fault signaling during brief voltage dips, which is particularly useful in unstable networks. The adjustable pickup voltage allows individual adaptation to the specific conditions of the respective network.
Compatibility and Accessories
The device is suitable for single- and three-phase connections and can be used in various network voltages, with a maximum nominal voltage of 3/N AC 500 / 290 V. It is compatible with other variants of the IL series, for example, models featuring phase sequence detection or a time delay t2 for returning to normal operation. The width of 17.5 mm allows mounting in standard installation distributors according to DIN 43 880.
Mounting and Installation
Mounting is performed in installation distributors with terminals located at the bottom. The depth is 59 mm. The terminals are designed for cable connections, and the devices are suitable for frequencies between 45 and 65 Hz. Installation requires no additional auxiliary voltage, simplifying wiring.
Operational Advantages
The relay provides reliable network monitoring without requiring additional power supply. Adjustable parameters such as pickup value and time delay allow flexible adaptation to different requirements. The LED indicator facilitates diagnostics during operation. The standby current principle ensures clear state indication and prevents false alarms during brief disturbances. The width of 17.5 mm and I-type construction make it compatible with common distributors in industrial and commercial applications.
Approvals and Markings
The device complies with the standard IEC/EN 60255-1 and carries the CCC approval. It is designed for use in industrial and commercial facilities that require high reliability and safety standards.
| Technical data | |
| 1- / 3-phase | 1, 3 |
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Nominal voltage max. | 3/N AC 500 / 290 V |
| Output contacts | 2 C/O contacts |
| Width | 17,5 mm |
| Type | IL 9171 |
| Operate delay | |
| Variant | |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3AC 400 V |
| Response value | 0,55 - 1,05 Un |
| Time delay | 0,5 - 20 s |
| Approvals and Markings | CCC |
| Variant | Without N. NC circuit operation. Settable time delay t1. Settable response value |
Questions & answers
What is the delivery time of Dold 0050133 IL9171.12/031 3AC400V 0.55-1.05UN undervoltage relay Tv=0.5-20S ?
The article Dold 0050133 IL9171.12/031 3AC400V 0.55-1.05UN undervoltage relay Tv=0.5-20S is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0050133 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0050133 IL9171.12/031 3AC400V 0.55-1.05UN undervoltage relay Tv=0.5-20S always at the best possible price. We can give you a discount of 2% on Dold 0050133 IL9171.12/031 3AC400V 0.55-1.05UN undervoltage relay Tv=0.5-20S if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0050133 IL9171.12/031 3AC400V 0.55-1.05UN undervoltage relay Tv=0.5-20S we can offer you a price of 157,04 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.