Product information for Dold 0049584:
Applications
The BD9080.12 is designed for use in industrial enclosures and is suitable for monitoring drives, pumps, air conditioning systems, and other three-phase consumers. It is used in installations where high operational safety and availability are required, such as in manufacturing, energy supply, or machine building. Early detection of voltage fluctuations, phase loss, or incorrect phase sequence enables preventive maintenance and prevents damage to connected devices.
Functions and Equipment in Detail
The device monitors voltage in the range of 0.7 to 1.3 times nominal voltage (3AC 400 V), with the adjustment range reduced to 0.8 to 1.1 times when using auxiliary voltage from the monitored network. The pickup delay is adjustable between 0.1 and 5 seconds, allowing adaptation to different requirements. The reset delay is also 0.1 to 5 seconds. Asymmetry detection occurs at deviations of ±8 to ±20 % of the pickup voltage, with the fault angle at approximately 120° ±15°. Repeatability is ≤ ±0.5 % of nominal voltage.
Technology Explained Simply
The phase monitor measures voltage values of the three phases (L1, L2, L3) and calculates the arithmetic mean over several half-waves of the rectified phase voltages. The reference phase is L3. The device can be used in networks with or without a neutral conductor. The auxiliary voltage (A1/A2) can also be drawn from the monitored network, simplifying installation. Power consumption is approximately 0.5 mA per phase (L1, L2) and 0.8 mA (L3) at nominal voltage. Hysteresis is ≤ 5 % of the pickup value, ensuring stable switching behavior.
Compatibility and Accessories
The device is designed for use in enclosures and has a width of 45 mm. The contact configuration includes two changeover contacts rated for switching operations according to AC 15 (2 A/AC 230 V) and DC 13 (1 A/DC 24 V). Electrical life is 250,000 switching operations at 1 A/AC 230 V, and mechanical life is at least 50 million switching operations. Short-circuit resistance is ensured with a maximum fuse rating of 4 A gG/gL. Operating temperature is between -20 °C and +60 °C, and storage temperature is also between -20 °C and +60 °C. Operating altitude is limited to ≤ 2000 m.
Mounting and Installation
Mounting is done in an enclosure. The terminal connections are clearly labeled: L1, L2, L3 for phase voltage, A1/A2 for auxiliary voltage, and contacts 11/12/14 and 21/22/24 for the two changeover contacts. LED indicators show the operating status: A1/A2 (auxiliary voltage), Umax (overvoltage), Umin (undervoltage), ∆ (asymmetry/phase sequence/power failure), and contact position. The status is indicated by five separate LEDs, each visually displaying the respective condition.
Advantages in Operation
The BD9080.12 enables early fault detection through precise and reliable monitoring of voltage, phase sequence, and asymmetry. The adjustable pickup delay prevents false alarms during short-term voltage fluctuations. High life expectancy and robust construction ensure long operational life with minimal maintenance. Compliance with IEC/EN 60255-1 ensures reliability and compatibility in industrial applications. CCC certification is also available.
| Technical data | |
| 1- / 3-phase | 3 |
| Enclosure design | Switch cabinet |
| Measuring range max. | 750 V |
| Output contacts | 2 C/O contacts |
| Standard measuring range | 3 AC 400 V |
| Width | 45 mm |
| Type | BD 9080 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC/DC 80 - 230 V |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3AC 400 V |
| Release delay | 0,1 - 5 s |
| Approvals and Markings | CCC |
| Variant | De-Energized on trip |
Questions & answers
What is the delivery time of Dold 0049584 BD9080.12 3AC400V UH AC/DC80-230V phase monitor Tv=0.1-5s?
The article Dold 0049584 BD9080.12 3AC400V UH AC/DC80-230V phase monitor Tv=0.1-5s is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0049584 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0049584 BD9080.12 3AC400V UH AC/DC80-230V phase monitor Tv=0.1-5s always at the best possible price. We can give you a discount of 2% on Dold 0049584 BD9080.12 3AC400V UH AC/DC80-230V phase monitor Tv=0.1-5s if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0049584 BD9080.12 3AC400V UH AC/DC80-230V phase monitor Tv=0.1-5s we can offer you a price of 404,19 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.