Further information for Dold 0049584 BD9080.12 3AC400V UH AC/DC80-230V phase monitor
Technical data
1- / 3-phase
3
Enclosure design
Switch cabinet
Measuring range max.
750 V
Output contacts
2 C/O contacts
Standard measuring range
3 AC 400 V
Width
45 mm
Type
BD 9080
Operate delay
Variant
Auxiliary voltage
AC/DC 80 - 230 V
Contact equipping
2 changeover contacts
Nominal voltage
3AC 400 V
Release delay
0,1 - 5 s
Approvals and Markings
CCC
Variant
De-Energized on trip
The phase monitor BD9080.12 from Dold is an industrial monitoring switch for three-phase AC power networks. It is designed for continuous monitoring of voltage levels, phase sequence, asymmetry, and power failure in systems with nominal voltage 3AC 400 V. The device operates on the standby current principle, where the output relay is not activated in the event of a fault, enabling safe and precise fault detection. The auxiliary voltage is AC/DC 80–230 V, allowing flexible use in various network configurations.
Applications
The BD9080.12 is designed for use in industrial enclosures and is suitable for monitoring drives, pumps, air conditioning systems, and other three-phase consumers. It is used in installations where high operational safety and availability are required, such as in manufacturing, energy supply, or machine building. Early detection of voltage fluctuations, phase loss, or incorrect phase sequence enables preventive maintenance and prevents damage to connected devices.
Functions and Equipment in Detail
The device monitors voltage in the range of 0.7 to 1.3 times nominal voltage (3AC 400 V), with the adjustment range reduced to 0.8 to 1.1 times when using auxiliary voltage from the monitored network. The pickup delay is adjustable between 0.1 and 5 seconds, allowing adaptation to different requirements. The reset delay is also 0.1 to 5 seconds. Asymmetry detection occurs at deviations of ±8 to ±20 % of the pickup voltage, with the fault angle at approximately 120° ±15°. Repeatability is ≤ ±0.5 % of nominal voltage.
Technology Explained Simply
The phase monitor measures voltage values of the three phases (L1, L2, L3) and calculates the arithmetic mean over several half-waves of the rectified phase voltages. The reference phase is L3. The device can be used in networks with or without a neutral conductor. The auxiliary voltage (A1/A2) can also be drawn from the monitored network, simplifying installation. Power consumption is approximately 0.5 mA per phase (L1, L2) and 0.8 mA (L3) at nominal voltage. Hysteresis is ≤ 5 % of the pickup value, ensuring stable switching behavior.
Compatibility and Accessories
The device is designed for use in enclosures and has a width of 45 mm. The contact configuration includes two changeover contacts rated for switching operations according to AC 15 (2 A/AC 230 V) and DC 13 (1 A/DC 24 V). Electrical life is 250,000 switching operations at 1 A/AC 230 V, and mechanical life is at least 50 million switching operations. Short-circuit resistance is ensured with a maximum fuse rating of 4 A gG/gL. Operating temperature is between -20 °C and +60 °C, and storage temperature is also between -20 °C and +60 °C. Operating altitude is limited to ≤ 2000 m.
Mounting and Installation
Mounting is done in an enclosure. The terminal connections are clearly labeled: L1, L2, L3 for phase voltage, A1/A2 for auxiliary voltage, and contacts 11/12/14 and 21/22/24 for the two changeover contacts. LED indicators show the operating status: A1/A2 (auxiliary voltage), Umax (overvoltage), Umin (undervoltage), ∆ (asymmetry/phase sequence/power failure), and contact position. The status is indicated by five separate LEDs, each visually displaying the respective condition.
Advantages in Operation
The BD9080.12 enables early fault detection through precise and reliable monitoring of voltage, phase sequence, and asymmetry. The adjustable pickup delay prevents false alarms during short-term voltage fluctuations. High life expectancy and robust construction ensure long operational life with minimal maintenance. Compliance with IEC/EN 60255-1 ensures reliability and compatibility in industrial applications. CCC certification is also available.