Dold 0049135 IL9151.12 2-450K-OHM AC230V 0.2-20S level relay
|
193,50 EUR |
|||||||||||
|
( 230,27 EUR incl. VAT ) ≈ £161.96 | ≈ $212.66 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1001936 | ||||||||||
| Mfg Part No: | 0049135 | ||||||||||
| UPC/EAN: | 4030641491352 | ||||||||||
| Weight: | 0.177 kg | ||||||||||
| Type: | IL9151.12 2-450K-OHM AC230V 0,2-20S | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0049135:
Applications
This relay is suitable for level monitoring in industrial plants, such as in tanks, containers, or silos. It can be used for monitoring conductive liquids, such as water, oils, or chemicals, as well as conductive powders. Applications also include limit temperature detection using PTC resistors and general resistance monitoring tasks. The maximum cable length to the electrodes is 3000 m, enabling flexible installation even over long distances.
Functions and Equipment in Detail
The device features three electrode terminals (MIN, MAX, COM), which can be used for 1-point and 2-point level control. The trigger value is adjustable via a rotary switch in the range of 2 to 450 kΩ, allowing differentiation between liquid and foam. The trigger and reset delay can be adjusted separately for MIN and MAX levels and ranges from 0.2 to 20 seconds. Programming is done by selecting between operating current and resting current principle, where the output relay is either activated (operating current) or not activated (resting current) in the event of a fault.
Technology Explained Simply
The measurement circuit operates with an internally generated alternating voltage of approximately 30 Hz, preventing electrolysis effects in the liquid. Galvanic isolation of the measurement circuit from the mains ensures high immunity to interference. The auxiliary voltage is AC 230 V. The device is specified according to IEC/EN 60255-1 and provides safe isolation according to IEC/EN 61140 and IEC/EN 60947-1. The output contacts consist of two relays, each with one changeover contact (2 x 1 changeover), which can be controlled either jointly or separately. The operating mode is selected via a bridge between terminals X1 and COM, and X2 and COM.
Compatibility and Accessories
The relay is compatible with standard market electrodes. The reference electrode (COM) is typically mounted at the lowest point of the container. If the container is made of conductive material, it can serve as the reference electrode itself. The output relays are controlled via terminals 11-14 (relay 1) and 21-24 (relay 2). Signal indication is provided by LEDs: green LED for operational readiness, yellow LED for activated MIN relay, red LED for activated MAX relay.
Mounting and Installation
The device is mounted in installation and industrial distributors according to DIN 43880. The connection terminals are located at the bottom. Mounting is done in a 35 mm wide rail format. The depth is 59 mm. Terminal designations include A1/A2 for auxiliary voltage, MIN/MAX/COM for electrode connections, X1/X2 for operating mode selection, and 11-14/21-24 for relay contacts.
Advantages in Operation
The separate adjustability of trigger value and delay time for MIN and MAX levels allows precise adaptation to specific applications. High immunity to interference and galvanic isolation ensure reliable measurement results. Integrated LEDs provide visual feedback on the operating status. Programmability for operating and resting current principles expands application possibilities. The maximum cable length of 3000 m reduces installation restrictions. UKCA and CCC certifications confirm compliance with European and Chinese safety standards.
| Technical data | |
| Classification | Füllstandsüberwachung |
| Enclosure design | Distribution board |
| Measuring range max. | 450 kΩ |
| Output contacts | 2 x 1 C/O contacts |
| Width | 35 mm |
| Type | IL 9151 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 230 V |
| Contact equipping | 2 x 1 changeover contact |
| Response and release delay | 0,2 - 20 s |
| Response value | 2 - 450 kOhm |
| Approvals and Markings | UKCA, CCC |
| Variant | Time delay, when level rises over and drops under setting value |
Questions & answers
What is the delivery time of Dold 0049135 IL9151.12 2-450K-OHM AC230V 0.2-20S level relay?
The article Dold 0049135 IL9151.12 2-450K-OHM AC230V 0.2-20S level relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0049135 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0049135 IL9151.12 2-450K-OHM AC230V 0.2-20S level relay always at the best possible price. We can give you a discount of 2% on Dold 0049135 IL9151.12 2-450K-OHM AC230V 0.2-20S level relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0049135 IL9151.12 2-450K-OHM AC230V 0.2-20S level relay we can offer you a price of 184,79 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

