Technical data
ClassificationFüllstandsüberwachung
Enclosure designDistribution board
Measuring range max.450 kΩ
Output contacts2 x 1 C/O contacts
Width35 mm
TypeIL 9151
Operate delayYes
Variant
Auxiliary voltageAC 230 V
Contact equipping2 x 1 changeover contact
Response and release delay0,2 - 20 s
Response value2 - 450 kOhm
Approvals and MarkingsUKCA, CCC
VariantTime delay, when level rises over and drops under setting value
The Dold level relay IL9151.12 is an industrial relay for level monitoring of conductive liquids and powders. It is designed for continuous monitoring of maximum and minimum fill levels, providing protection against overfilling and dry running, as well as enabling control of the mixing ratio of conductive liquids. The device is designed for use in installation and industrial distributors according to DIN 43880 and features a width of 35 mm and a depth of 59 mm. The housing design is configured as an installation distributor.

Applications
This relay is suitable for level monitoring in industrial plants, such as in tanks, containers, or silos. It can be used for monitoring conductive liquids, such as water, oils, or chemicals, as well as conductive powders. Applications also include limit temperature detection using PTC resistors and general resistance monitoring tasks. The maximum cable length to the electrodes is 3000 m, enabling flexible installation even over long distances.

Functions and Equipment in Detail
The device features three electrode terminals (MIN, MAX, COM), which can be used for 1-point and 2-point level control. The trigger value is adjustable via a rotary switch in the range of 2 to 450 kΩ, allowing differentiation between liquid and foam. The trigger and reset delay can be adjusted separately for MIN and MAX levels and ranges from 0.2 to 20 seconds. Programming is done by selecting between operating current and resting current principle, where the output relay is either activated (operating current) or not activated (resting current) in the event of a fault.

Technology Explained Simply
The measurement circuit operates with an internally generated alternating voltage of approximately 30 Hz, preventing electrolysis effects in the liquid. Galvanic isolation of the measurement circuit from the mains ensures high immunity to interference. The auxiliary voltage is AC 230 V. The device is specified according to IEC/EN 60255-1 and provides safe isolation according to IEC/EN 61140 and IEC/EN 60947-1. The output contacts consist of two relays, each with one changeover contact (2 x 1 changeover), which can be controlled either jointly or separately. The operating mode is selected via a bridge between terminals X1 and COM, and X2 and COM.

Compatibility and Accessories
The relay is compatible with standard market electrodes. The reference electrode (COM) is typically mounted at the lowest point of the container. If the container is made of conductive material, it can serve as the reference electrode itself. The output relays are controlled via terminals 11-14 (relay 1) and 21-24 (relay 2). Signal indication is provided by LEDs: green LED for operational readiness, yellow LED for activated MIN relay, red LED for activated MAX relay.

Mounting and Installation
The device is mounted in installation and industrial distributors according to DIN 43880. The connection terminals are located at the bottom. Mounting is done in a 35 mm wide rail format. The depth is 59 mm. Terminal designations include A1/A2 for auxiliary voltage, MIN/MAX/COM for electrode connections, X1/X2 for operating mode selection, and 11-14/21-24 for relay contacts.

Advantages in Operation
The separate adjustability of trigger value and delay time for MIN and MAX levels allows precise adaptation to specific applications. High immunity to interference and galvanic isolation ensure reliable measurement results. Integrated LEDs provide visual feedback on the operating status. Programmability for operating and resting current principles expands application possibilities. The maximum cable length of 3000 m reduces installation restrictions. UKCA and CCC certifications confirm compliance with European and Chinese safety standards.