Dold 0048953 BA9094.28/100 AC230V P1=60-150C temperature monitor P2=60-150C
|
320,64 EUR |
|||||||||||
|
( 381,56 EUR incl. VAT ) ≈ £268.38 | ≈ $352.38 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1153675 | ||||||||||
| Mfg Part No: | 0048953 | ||||||||||
| UPC/EAN: | 4030641489533 | ||||||||||
| Weight: | 0.35 kg | ||||||||||
| Type: | BA9094.28/100 AC230V P1=60-150C | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0048953:
Applications
The temperature monitor is suitable for continuous monitoring of operating temperatures in industrial systems. It is particularly used in motors, bearings, and rooms where overheating or sensor failure must be detected and signaled. The 2-wire technology enables simple installation, as PT100 sensors are connected via two wires. Wire break detection ensures that a broken sensor or wiring fault is also recognized as an error.
Functions and equipment in detail
The device features two outputs: a changeover contact for the first switching point (P1) and a make contact for the second switching point (P2). The trigger values for both outputs are adjustable in the range of 60 °C to 150 °C. The hysteresis, i.e., the difference between trigger and reset value, is 85 % to 95 % of the set trigger value. The outputs operate on the rest current principle, meaning the relay is activated during normal operation and de-energizes when the trigger value is exceeded or in case of wire break. This enables clear error indication via the output contacts.
Technology explained simply
Temperature measurement is performed via a PT100 sensor, which functions as a resistance thermometer. As temperature increases, the sensor's resistance rises, which is detected by the relay. When the set trigger value is reached, the relay de-energizes. LED indicators (red for fault, green for operation) visually signal the status. The auxiliary voltage of AC 230 V powers the device, with a rated consumption of 3.4 VA. The operating temperature of the device ranges from -20 °C to +60 °C, and the storage temperature ranges from -25 °C to +70 °C.
Compatibility and accessories
The device is designed for use with PT100 sensors connected in 2-wire technology. It is equipped with a single PT100 input, which can control two separate outputs, each with its own trigger value. The use of additional relays or switching devices for further signal processing is possible, but not part of the device.
Mounting and installation
The temperature monitor is mounted in enclosures and requires a width of 45 mm. The connection terminals are clearly labeled: A1 and A2 for auxiliary voltage, P0, P1, P2 for PT100 sensors, and 11-12-14 for the changeover contact and 23-24 for the make contact. Mounting is for continuous operation, and the maximum operating altitude is 2000 m above sea level. The electrical life at 5 A and AC 230 V exceeds 0.1 million switching operations.
Advantages in operation
The separate adjustment of trigger values for the two outputs enables flexible use, e.g., for different alarm levels. Wire break detection increases reliability by recognizing mechanical faults. Clear signaling via LEDs and a mechanical life of over 30 million switching operations ensure long service life. Compliance with the standard IEC/EN 60255-1 ensures reliability in industrial applications.
More spare projector bulbs for your 3M Beamer
| Technical data | |
| Classification | Temperaturüberwachung |
| Enclosure design | Switch cabinet |
| Measuring range max. | 100 °C |
| Output contacts | 1 C/O contact, 1 NO contact |
| Width | 45 mm |
| Type | BA 9094 |
| Variant | |
| Auxiliary voltage | AC 230 V |
| Contact equipping | 1 changeover contact for P1, 1 NO contact for P2 |
| Response value / Reset value P1 | only response value |
| Response value / Reset value P2 | only response value |
| Response value P1 = P2 | 60 - 150 C |
| Variant | 1 PT 100 input. 2 outputs. Seperate adjustable response and release value for every output |
Questions & answers
What is the delivery time of Dold 0048953 BA9094.28/100 AC230V P1=60-150C temperature monitor P2=60-150C?
The article Dold 0048953 BA9094.28/100 AC230V P1=60-150C temperature monitor P2=60-150C is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0048953 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0048953 BA9094.28/100 AC230V P1=60-150C temperature monitor P2=60-150C always at the best possible price. We can give you a discount of 2% on Dold 0048953 BA9094.28/100 AC230V P1=60-150C temperature monitor P2=60-150C if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0048953 BA9094.28/100 AC230V P1=60-150C temperature monitor P2=60-150C we can offer you a price of 306,21 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.