Dold 0048873 IK9171.11/041 3AC400V 0.55-1.05UN4% undervoltage relay Tv=0.5-20s
|
114,68 EUR |
|||||||||||
|
( 136,47 EUR incl. VAT ) ≈ £95.99 | ≈ $126.03 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1153825 | ||||||||||
| Mfg Part No: | 0048873 | ||||||||||
| UPC/EAN: | 4030641488734 | ||||||||||
| Weight: | 0.073 kg | ||||||||||
| Type: | IK9171.11/041 3AC400V 0,55-1,05UN4% | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0048873:
Applications
This relay is used in industrial and commercial installations where reliable network monitoring is required. It is particularly suitable for applications in which certain consumer groups must be switched off during voltage dips or phase failures and re-energized after a defined waiting period. This applies, for example, in unstable power networks, such as those found in local power generation or in networks of the 2nd and 3rd world. It is also suitable for consumers that must not be re-energized immediately after a short power failure – such as compressors or certain processing machines.
Functions and equipment in detail
The device monitors three-phase networks for undervoltage and can also be connected single-phase. The rated voltage is 3AC 400 V, with a maximum rated voltage of 3/N AC 500/290 V. The pickup value is adjustable within a range of 0.55 to 1.05 times the rated voltage, with a hysteresis of approximately 4 %. The time delay t2 for returning to the normal state is adjustable between 0.5 and 20 seconds. The contact configuration includes a changeover contact, which is used for controlling auxiliary functions or safety circuits. A yellow LED indicates the contact position – it lights up when the output relay is activated (contacts 11-14 closed).
Technology explained simply
The relay measures the arithmetic mean of each phase against the neutral conductor (N). In variants without a neutral conductor connection, L1 and L3 are measured against L2 (for IK/SK 9171) or L1 and L2 against L3 (for IL/SL 9171). In single-phase connection, the terminals L1, L2, and L3 must be connected together. The time delay t1 is only effective if the phase voltage L1-N (IK/SK 9171) or L3-N (IL/SL 9171) is at least 0.5 times the rated voltage. After switching on the operating voltage, the device initially enters the normal state, even if a fault is present. It only switches to the fault state after the time delay t1 has elapsed. The function is certified in accordance with IEC/EN 60255-1 and bears the UKCA mark.
Compatibility and accessories
The device is suitable for 1- or 3-phase connections and can operate without auxiliary voltage. It is designed in I form, which has a depth of 59 mm and bottom-mounted terminals for installation and industrial distributors in accordance with DIN 43 880. The width of 17.5 mm allows mounting in standard distributor boxes. It is not equipped with a neutral conductor connection and operates on the rest current principle. The time delay t2 is adjustable, as is the pickup value.
Mounting and installation
Mounting is carried out in installation distributor boxes in accordance with DIN 43 880. The terminals are located at the bottom, enabling easy integration into existing switchgear. The mounting width of 17.5 mm corresponds to the standard for modular components. The frequency range coverage is between 45 and 65 Hz. The overload capacity is 1.15 times the rated voltage continuously. The rated consumption values are approximately 6 VA for the IK/SK 9171.11 variant.
Advantages in operation
The relay provides reliable and low-maintenance network monitoring without auxiliary voltage. The adjustable pickup values and time delays allow application-specific adaptation. The LED indicator facilitates diagnosis of the operating state. The form factor is optimized for use in installation distributor boxes, ensuring compact and secure mounting. Compliance with standards IEC/EN 60255-1 and DIN VDE 0100-710 ensures conformity with applicable safety requirements.
More spare projector bulbs for your Epson Beamer
| Technical data | |
| 1- / 3-phase | 1, 3 |
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Nominal voltage max. | 3/N AC 500 / 290 V |
| Output contacts | 1 C/O contact |
| Width | 17,5 mm |
| Type | IK 9171 |
| Operate delay | |
| Variant | |
| Contact equipping | 1 changeover contact |
| Nominal voltage | 3AC 400 V |
| Response value | 0,55 - 1,05 Un 4% |
| Time delay | 0,5 - 20 s |
| Approvals and Markings | UKCA |
| Variant | Without N. NC circuit operation. Settable time delay t2. Settable response value |
Questions & answers
What is the delivery time of Dold 0048873 IK9171.11/041 3AC400V 0.55-1.05UN4% undervoltage relay Tv=0.5-20s?
The article Dold 0048873 IK9171.11/041 3AC400V 0.55-1.05UN4% undervoltage relay Tv=0.5-20s is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0048873 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0048873 IK9171.11/041 3AC400V 0.55-1.05UN4% undervoltage relay Tv=0.5-20s always at the best possible price. We can give you a discount of 2% on Dold 0048873 IK9171.11/041 3AC400V 0.55-1.05UN4% undervoltage relay Tv=0.5-20s if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0048873 IK9171.11/041 3AC400V 0.55-1.05UN4% undervoltage relay Tv=0.5-20s we can offer you a price of 109,52 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

