Dold 0047644 IK9171.11/240 3/N AC380/220V 0.75UN undervoltage relay Tv=5-15M
|
114,68 EUR |
|||||||||||
|
( 136,47 EUR incl. VAT ) ≈ £95.99 | ≈ $126.03 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1153829 | ||||||||||
| Mfg Part No: | 0047644 | ||||||||||
| UPC/EAN: | 4030641476441 | ||||||||||
| Weight: | 0.123 kg | ||||||||||
| Type: | IK9171.11/240 3/N AC380/220V 0,75UN | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0047644:
Applications
This relay is used in industrial and commercial facilities where reliable network monitoring is required. It serves, for example, to protect machines, systems, or lighting installations from damage caused by insufficient voltage. The variant with time delay t2 for returning to the normal state is particularly suitable for unstable power networks, such as those found in local power generation or in networks of the 2nd and 3rd world. In such cases, consumer groups can be reconnected in stages after a network fault to ensure network stability. This variant is also useful for consumers that must not be immediately reconnected after a short power interruption—for example, compressors or certain processing machines.
Functions and Equipment in Detail
The device monitors three-phase networks for undervoltage with a fixed pickup value of 0.75 Un. The rated voltage is 3/N AC 380/220 V, and the device can also be connected single-phase. For single-phase connection, terminals L1, L2, and L3 must be bridged. The time delay t2 for returning to the normal state is adjustable and ranges from 5 to 15 minutes. The contact configuration includes a changeover contact, which is used for controlling auxiliary functions or safety circuits. Phase sequence is arbitrary, and the device detects undervoltage regardless of phase order.
Technology Explained Simply
Voltage detection is performed by measuring the arithmetic mean of each phase against the neutral conductor (N). In versions without neutral conductor connection, L1 and L3 are measured against L2 (for IK/SK 9171) or L1 and L2 against L3 (for IL/SL 9171). The hysteresis is approximately 4%, ensuring stable switching behavior during voltage fluctuations. The time delay t1 is only effective if the phase voltage L1-N (IK/SK 9171) or L3-N (IL/SL 9171) is at least 0.5 Un. After switching on the operating voltage, the device initially enters the normal state, even if a fault is present. The fault state is only activated after the time delay t1 has elapsed.
Compatibility and Accessories
The relay is suitable for single- and three-phase connections and can be used in various network voltages, with a maximum rated voltage of 3/N AC 500/290 V. It is designed for frequencies between 45 and 65 Hz. The device variant includes a neutral conductor connection and complies with the standard IEC/EN 60255-1. The UKCA approval is available.
Mounting and Installation
The device is designed in I-form, with a depth of 59 mm and terminals located at the bottom. It is intended for installation and industrial distributors in accordance with DIN 43 880. Mounting is carried out in standard distributor boxes, with the terminals for connection cables directly accessible. The width of 17.5 mm allows for compact placement in distributors.
Advantages in Operation
The relay provides reliable and low-maintenance network monitoring without additional auxiliary voltage. The adjustable time delay t2 enables controlled reactivation of consumers after a network fault. The LED indicator allows for quick visual status monitoring. The rest current principle reduces fault susceptibility and increases the service life of the output relay. Compliance with standards DIN VDE 0100-710 and DIN VDE 0108 ensures integration into safety systems.
More spare projector bulbs for your Epson Beamer
| Technical data | |
| 1- / 3-phase | 1, 3 |
| Auxiliary voltage | Without |
| Enclosure design | Distribution board |
| Nominal voltage max. | 3/N AC 500 / 290 V |
| Output contacts | 1 C/O contact |
| Width | 17,5 mm |
| Type | IK 9171 |
| Operate delay | |
| Variant | |
| Contact equipping | 1 changeover contact |
| Nominal voltage | 3/N AC 380 / 220 V |
| Response value | 0,75 Un |
| Time delay | 5 - 15 min |
| Approvals and Markings | UKCA |
| Variant | With N. NC circuit operation. Settable time delay t2. Fixed response value |
Questions & answers
What is the delivery time of Dold 0047644 IK9171.11/240 3/N AC380/220V 0.75UN undervoltage relay Tv=5-15M?
The article Dold 0047644 IK9171.11/240 3/N AC380/220V 0.75UN undervoltage relay Tv=5-15M is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0047644 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0047644 IK9171.11/240 3/N AC380/220V 0.75UN undervoltage relay Tv=5-15M always at the best possible price. We can give you a discount of 2% on Dold 0047644 IK9171.11/240 3/N AC380/220V 0.75UN undervoltage relay Tv=5-15M if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0047644 IK9171.11/240 3/N AC380/220V 0.75UN undervoltage relay Tv=5-15M we can offer you a price of 109,52 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.