Dold 0047644, EAN: 4030641476441

Dold 0047644 IK9171.11/240 3/N AC380/220V 0,75UN undervoltage relay

Dold 0047644 IK9171.11/240 3/N AC380/220V 0,75UN undervoltage relay

Lieske Part No. 1153829
Mfg Part No 0047644
EAN-Code 4030641476441
Manufacturer Dold
Here only 114,68 EUR
136,47 EUR incl. VAT

Further information for Dold 0047644 IK9171.11/240 3/N AC380/220V 0,75UN undervoltage relay

Technical data
1- / 3-phase1, 3
Auxiliary voltageWithout
Enclosure designDistribution board
Nominal voltage max.3/N AC 500 / 290 V
Output contacts1 C/O contact
Width17,5 mm
TypeIK 9171
Operate delayYes
Variant
Contact equipping1 changeover contact
Nominal voltage3/N AC 380 / 220 V
Response value0,75 Un
Time delay5 - 15 min
Approvals and MarkingsUKCA
VariantWith N. NC circuit operation. Settable time delay t2. Fixed response value
The Dold undervoltage relay IK9171.11/240 is an industrial-grade monitoring device for detecting undervoltage in three-phase power networks. It is designed for network monitoring and automatic switching to safety power supply or safety lighting in accordance with DIN VDE 0100-710 and DIN VDE 0108. The device operates on the rest current principle, in which the output relay is not activated in the event of a fault, and can operate without auxiliary voltage. It features an LED indicator that visually signals the status of the output relay. The width is 17.5 mm, and the housing design is intended for installation distributors.

Applications
This relay is used in industrial and commercial facilities where reliable network monitoring is required. It serves, for example, to protect machines, systems, or lighting installations from damage caused by insufficient voltage. The variant with time delay t2 for returning to the normal state is particularly suitable for unstable power networks, such as those found in local power generation or in networks of the 2nd and 3rd world. In such cases, consumer groups can be reconnected in stages after a network fault to ensure network stability. This variant is also useful for consumers that must not be immediately reconnected after a short power interruption—for example, compressors or certain processing machines.

Functions and Equipment in Detail
The device monitors three-phase networks for undervoltage with a fixed pickup value of 0.75 Un. The rated voltage is 3/N AC 380/220 V, and the device can also be connected single-phase. For single-phase connection, terminals L1, L2, and L3 must be bridged. The time delay t2 for returning to the normal state is adjustable and ranges from 5 to 15 minutes. The contact configuration includes a changeover contact, which is used for controlling auxiliary functions or safety circuits. Phase sequence is arbitrary, and the device detects undervoltage regardless of phase order.

Technology Explained Simply
Voltage detection is performed by measuring the arithmetic mean of each phase against the neutral conductor (N). In versions without neutral conductor connection, L1 and L3 are measured against L2 (for IK/SK 9171) or L1 and L2 against L3 (for IL/SL 9171). The hysteresis is approximately 4%, ensuring stable switching behavior during voltage fluctuations. The time delay t1 is only effective if the phase voltage L1-N (IK/SK 9171) or L3-N (IL/SL 9171) is at least 0.5 Un. After switching on the operating voltage, the device initially enters the normal state, even if a fault is present. The fault state is only activated after the time delay t1 has elapsed.

Compatibility and Accessories
The relay is suitable for single- and three-phase connections and can be used in various network voltages, with a maximum rated voltage of 3/N AC 500/290 V. It is designed for frequencies between 45 and 65 Hz. The device variant includes a neutral conductor connection and complies with the standard IEC/EN 60255-1. The UKCA approval is available.

Mounting and Installation
The device is designed in I-form, with a depth of 59 mm and terminals located at the bottom. It is intended for installation and industrial distributors in accordance with DIN 43 880. Mounting is carried out in standard distributor boxes, with the terminals for connection cables directly accessible. The width of 17.5 mm allows for compact placement in distributors.

Advantages in Operation
The relay provides reliable and low-maintenance network monitoring without additional auxiliary voltage. The adjustable time delay t2 enables controlled reactivation of consumers after a network fault. The LED indicator allows for quick visual status monitoring. The rest current principle reduces fault susceptibility and increases the service life of the output relay. Compliance with standards DIN VDE 0100-710 and DIN VDE 0108 ensures integration into safety systems.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1153829
qrcode für Dold 0047644 IK9171.11/240 3/N AC380/220V 0,75UN undervoltage relay