Online retailer for industrial customers, commercial customers and public institutions - no sales to private customers
Switch to german languageIndustry-Electronics in English

Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset

Your rating:
Average rating
product review for Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset
( 4.7 / 5 ) 3 ratings
Dold 0044940
This image may differ from the desired article.
123,75 EUR
( 147,26 EUR incl. VAT )
≈ £103.58  |  ≈ $136.00
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset
Datasheet:file_download Download
Lieske Part No.:1154024
Mfg Part No: 0044940
UPC/EAN: 4030641449407
Weight:0.2 kg
Type:MK9962 AC/DC24V+AC220-240V 3-60M
Graduated prices net
From piecesPrice per pieces
5118,18 EUR
10112,61 EUR
15107,04 EUR
20101,48 EUR

Product information for Dold 0044940:

The Dold MK9962 is a delayed-release time relay with control signal, designed for use in industrial enclosures. It features a dual-voltage configuration with rated voltages AC/DC 24 V and AC 220–240 V, enabling flexible integration into various systems. The time function is implemented as delayed release, meaning the relay energizes upon activation of the control signal and closes the output contacts. Once the control signal is removed, a time-controlled reset begins, which can be adjusted via a continuously variable rotary switch in the range of 3 to 60 minutes. Adjustment is made on an absolute scale, allowing precise and repeatable setting of the delay time.

Delayed release is the core function of the device: the output contacts remain closed until the set delay time has elapsed. This enables time-controlled sequences in automation systems, for example, for controlled motor shutdown or signal delay in controls. The repeatability is ≤ ±1 % of the set value, ensuring high precision in repeated switching operations. The minimum switching-on time is 20 ms, and the re-readiness time is approximately 5 ms, suitable for fast sequential switching operations.

Technology explained simply: The device is actuated via potential-free contacts at control inputs B1–B2. These are electrically connected to the operating voltage terminals A1–A2–A3, which is why galvanic isolation is required to ensure safe actuation. The operating voltage is connected at terminals A1–A2–A3, with voltage supplied at A3–A2 (for DC/AC 24 V) and at A1–A2 (for AC 220–240 V). The output contacts consist of two changeover contacts (C/O contacts) made of silver-tin oxide (AgSnO₂), ensuring high switching durability and corrosion resistance. The rated operating voltage is AC 250 V, and the thermal current (Ith) is 5 A.

Applications: The relay is suitable for time-dependent controls in industrial plants, for example, in conveyor technology, machine building, or building technology. It can be used for delaying switching operations, signal delay, or actuating auxiliary devices. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range matches the operating temperature range. The operating altitude is limited to a maximum of 2000 m above sea level.

Functions and equipment in detail: The device features two LED indicators: the upper LED lights up when the control contact is closed, and the lower LED indicates the state of the output relay. This enables simple fault diagnosis, as the operating state can be visually monitored. The contact configuration includes two changeover contacts designed for switching operations with a switching capacity according to AC 15: normally open contacts (1 A / AC 230 V) and normally closed contacts (3 A / AC 230 V). The electrical life is at least 500,000 switching cycles at 5 A and AC 230 V, and the mechanical life is 30 million switching cycles. The permissible switching frequency is 6000 switching cycles per hour.

Compatibility and accessories: The relay is designed for use in enclosures and has a width of 22.5 mm, making it suitable for standard DIN rails. It complies with the standard EN 61812-1 for time relays. The insulation test voltage is 2.5 kV for a duration of 1 minute. The overvoltage category is III, and the rated impulse voltage is 4 kV at pollution degree 2. EMC requirements are met according to IEC/EN 61000-4-2 to -4-5, including immunity to electrostatic discharge (8 kV), high-frequency radiation, and fast transients (2 kV). The voltage influence limit is ≤ ±0.5 %, and the temperature influence is < ±0.1 % per Kelvin.

Operational advantages: The continuously variable adjustment of the delay time via a rotary switch allows precise adaptation to specific requirements. The LED indicators simplify maintenance and diagnosis, as the operating state is directly visible. The high repeatability and long service life ensure reliable operation in demanding industrial environments. The device is designed for continuous operation and can be operated in a temperature range from -20 °C to +60 °C.

Mounting and installation: The relay is mounted in enclosures and attached to a DIN rail. The connection terminals are clearly labeled: A1–A2–A3 for operating voltage, B1–B2 for control input, and 15–16–18 as well as 25–26–28 for output contacts. Actuation is via potential-free contacts, with galvanic isolation required between control input and operating voltage. Mounting is tool-free, as the device is designed for DIN rails.

Technical data
Enclosure designSwitch cabinet
Output contacts2 C/O contacts
Time function(s)Off-delay, with control signal
Width22,5 mm
TypeMK 9962
Variant
Contact equipping2 changeover contacts delayed
Nominal voltageAC/DC 24 V + AC 220 - 240 V
Time range3 - 60 min
VariantRelease delay, with control signal


Product data sheet
Datasheet for Dold 0044940, EAN: 4030641449407

Questions & answers

What is the delivery time of Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset?

The article Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0044940 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset always at the best possible price. We can give you a discount of 2% on Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset we can offer you a price of 118,18 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0044940 time relay delayed return
Dold 0044940 MK9962 AC/DC24V+AC220-240V 3-60M time relay, delayed reset
123,75 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0044940 time relay delayed return
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
9 + 3 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.