Dold 0044769 BA9043 3/N AC50-400Hz 400/690V undervoltage relay
|
262,20 EUR |
|||||||||||
|
( 312,02 EUR incl. VAT ) ≈ £219.46 | ≈ $288.16 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1153811 | ||||||||||
| Mfg Part No: | 0044769 | ||||||||||
| UPC/EAN: | 4030641447694 | ||||||||||
| Weight: | 0.34 kg | ||||||||||
| Type: | BA9043 3/N AC50-400HZ 400/690V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0044769:
Applications
This relay is suitable for use in industrial plants, power supply systems, and railway installations where stable and continuous power supply is critical. It monitors network voltages in the range of 3/N AC 100/57 V to 690/400 V and is thus compatible with a wide range of nominal voltages. The application is in enclosures, with a width of 45 mm allowing for compact mounting on a DIN rail. The operating temperature ranges from -20 °C to +60 °C, enabling use even in industrial environments with variable temperatures.
Functions and Equipment in Detail
The BA9043 features two changeover contacts as output contacts, which are used for switching operations in case of faults. The contacts are rated for a thermal current of up to 6 A per contact and meet switching capacities according to AC 15 (make: 2 A / AC 230 V) and DC 13 (break: 1 A / DC 24 V). The electrical life expectancy is at least 200,000 switching operations at 3 A and AC 230 V, while the mechanical life expectancy exceeds 30 million switching operations. LED indicators signal operational readiness (red LED) and activation of the output relay (green LED), enabling quick fault localization. The device operates on the principle of residual current, meaning the output relay is not activated in the event of a fault, but only when voltage is restored.
Technology Explained Simply
Voltage monitoring is performed by measuring the three phases against the neutral conductor, with the arithmetic mean of the voltage being calculated. This value is compared with the set pickup value. The pickup value is continuously adjustable between 0.85 and 1.05 of the nominal voltage, while the drop-out value (hysteresis) ranges from 0.75 to 0.95 of the pickup value. Time delay is not available in this variant, so the relay reacts immediately to voltage dips below 0.4 of the nominal voltage. Adjustment is made via two rotary knobs on the front panel, allowing for simple and precise adaptation to specific requirements. The devices are designed for continuous operation and consume 4 VA during operation.
Compatibility and Accessories
The relay is suitable for networks with or without a neutral conductor, with the variant described here specifically designed for systems with a neutral conductor (3/N). The connection terminals are designed for connection with solid or flexible conductors according to DIN 46228, with cross-sections up to 2.5 mm² (solid) or 1.5 mm² (flexible). Mounting is on a DIN rail according to IEC/EN 60715. The devices are certified according to IEC/EN 60255-1 and carry the UKCA mark. The overvoltage category is III, with a rated impulse voltage of 6 kV at pollution degree 2.
Mounting and Installation
Mounting is on a DIN rail within the enclosure. The connection terminals are equipped with self-lifting terminals (M3.5), requiring a torque of 0.8 Nm. Cable ends must be stripped to a length of 10 mm. Terminal markings are L1, L2, L3, and N for the network to be monitored, and 11, 12, 14 and 21, 22, 24 for the two changeover contacts. The devices are designed for operation at altitudes up to 2000 m above sea level.
Operational Advantages
Continuous voltage monitoring enables preventive maintenance and contributes to higher productivity, as failures can be detected and resolved early. LED indicators simplify diagnosis, and the simple adjustment via rotary potentiometers reduces commissioning time. The device is insensitive to harmonics, ensuring reliable operation even in networks with harmonic distortions. The high mechanical and electrical life expectancy ensures long service life with minimal maintenance effort.
More spare projector bulbs for your Epson Beamer
| Technical data | |
| 1- / 3-phase | 3 |
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | 3/N AC 690 / 400 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9043 |
| Operate delay | |
| Variant | |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3/N 400/690 V |
| Time delay | without |
| Approvals and Markings | UKCA |
| Variant | For 3p4w systems |
Questions & answers
What is the delivery time of Dold 0044769 BA9043 3/N AC50-400Hz 400/690V undervoltage relay?
The article Dold 0044769 BA9043 3/N AC50-400Hz 400/690V undervoltage relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0044769 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0044769 BA9043 3/N AC50-400Hz 400/690V undervoltage relay always at the best possible price. We can give you a discount of 2% on Dold 0044769 BA9043 3/N AC50-400Hz 400/690V undervoltage relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0044769 BA9043 3/N AC50-400Hz 400/690V undervoltage relay we can offer you a price of 250,40 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.