Dold 0044769, EAN: 4030641447694

Dold 0044769 BA9043 3/N undervoltage relay

Dold 0044769 BA9043 3/N undervoltage relay

Lieske Part No. 1153811
Mfg Part No 0044769
EAN-Code 4030641447694
Manufacturer Dold
Here only 262,20 EUR
312,02 EUR incl. VAT

Further information for Dold 0044769 BA9043 3/N undervoltage relay

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.3/N AC 690 / 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9043
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3/N 400/690 V
Time delaywithout
Approvals and MarkingsUKCA
VariantFor 3p4w systems
The under-voltage relay BA9043 from the VARIMETER series by Dold monitors 3-phase AC networks and is specifically designed for industrial applications as well as railway applications. It is used for continuous monitoring of the network voltage to initiate timely measures in case of voltage dips or failures. The device is designed for three-phase networks with a neutral conductor and operates in the frequency range of 50 to 400 Hz. Measurement is performed by calculating the arithmetic mean of the voltage of the three phases against the neutral conductor, ensuring precise and reliable voltage monitoring. Device settings are adjusted via rotary potentiometers on the front panel, enabling user-friendly and stepless adjustment of the pickup and drop-out values.

Applications
This relay is suitable for use in industrial plants, power supply systems, and railway installations where stable and continuous power supply is critical. It monitors network voltages in the range of 3/N AC 100/57 V to 690/400 V and is thus compatible with a wide range of nominal voltages. The application is in enclosures, with a width of 45 mm allowing for compact mounting on a DIN rail. The operating temperature ranges from -20 °C to +60 °C, enabling use even in industrial environments with variable temperatures.

Functions and Equipment in Detail
The BA9043 features two changeover contacts as output contacts, which are used for switching operations in case of faults. The contacts are rated for a thermal current of up to 6 A per contact and meet switching capacities according to AC 15 (make: 2 A / AC 230 V) and DC 13 (break: 1 A / DC 24 V). The electrical life expectancy is at least 200,000 switching operations at 3 A and AC 230 V, while the mechanical life expectancy exceeds 30 million switching operations. LED indicators signal operational readiness (red LED) and activation of the output relay (green LED), enabling quick fault localization. The device operates on the principle of residual current, meaning the output relay is not activated in the event of a fault, but only when voltage is restored.

Technology Explained Simply
Voltage monitoring is performed by measuring the three phases against the neutral conductor, with the arithmetic mean of the voltage being calculated. This value is compared with the set pickup value. The pickup value is continuously adjustable between 0.85 and 1.05 of the nominal voltage, while the drop-out value (hysteresis) ranges from 0.75 to 0.95 of the pickup value. Time delay is not available in this variant, so the relay reacts immediately to voltage dips below 0.4 of the nominal voltage. Adjustment is made via two rotary knobs on the front panel, allowing for simple and precise adaptation to specific requirements. The devices are designed for continuous operation and consume 4 VA during operation.

Compatibility and Accessories
The relay is suitable for networks with or without a neutral conductor, with the variant described here specifically designed for systems with a neutral conductor (3/N). The connection terminals are designed for connection with solid or flexible conductors according to DIN 46228, with cross-sections up to 2.5 mm² (solid) or 1.5 mm² (flexible). Mounting is on a DIN rail according to IEC/EN 60715. The devices are certified according to IEC/EN 60255-1 and carry the UKCA mark. The overvoltage category is III, with a rated impulse voltage of 6 kV at pollution degree 2.

Mounting and Installation
Mounting is on a DIN rail within the enclosure. The connection terminals are equipped with self-lifting terminals (M3.5), requiring a torque of 0.8 Nm. Cable ends must be stripped to a length of 10 mm. Terminal markings are L1, L2, L3, and N for the network to be monitored, and 11, 12, 14 and 21, 22, 24 for the two changeover contacts. The devices are designed for operation at altitudes up to 2000 m above sea level.

Operational Advantages
Continuous voltage monitoring enables preventive maintenance and contributes to higher productivity, as failures can be detected and resolved early. LED indicators simplify diagnosis, and the simple adjustment via rotary potentiometers reduces commissioning time. The device is insensitive to harmonics, ensuring reliable operation even in networks with harmonic distortions. The high mechanical and electrical life expectancy ensures long service life with minimal maintenance effort.