Dold 0044746 BA9043/001 3AC50-400Hz 690V undervoltage relay
|
270,07 EUR |
|||||||||||
|
( 321,38 EUR incl. VAT ) ≈ £226.05 | ≈ $296.81 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 167000 | ||||||||||
| Mfg Part No: | 0044746 | ||||||||||
| UPC/EAN: | 4030641447465 | ||||||||||
| Weight: | 0.34 kg | ||||||||||
| Type: | BA9043/001 3AC50/60HZ 690V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0044746:
Applications
This relay is used in industrial enclosures to ensure the operational safety of machines, drives, or entire production systems. It monitors 3-phase AC networks in the frequency range of 50 to 400 Hz. The design is intended for installation in enclosures, with a width of 45 mm, enabling compact mounting.
Functions and Features in Detail
The device monitors voltage via arithmetic mean measurement. For the BA9043/001 variant, designed for networks without a neutral conductor, phases L1 and L2 are measured against L3. The pickup and dropout values are adjusted using rotary potentiometers on the front of the device, allowing user-friendly and precise adaptation to specific applications. The pickup value is continuously adjustable between 0.85 and 1.05 of the nominal voltage, and the hysteresis (dropout ratio) ranges from 0.75 to 0.95 of the pickup value. The time delay is not present in this variant, meaning the relay reacts immediately upon undervoltage.
Technology Explained Simply
The relay operates on the standby current principle, where the output relay remains inactive in the event of a fault and stays in its resting state. This prevents unwanted switching operations and increases reliability. LED indicators show operational readiness (red LED) and contact position (green LED), simplifying diagnosis of operating states and faults. The device is harmonic-insensitive, meaning it functions reliably even during network disturbances caused by harmonic overvoltages. The operating temperature range is -20 °C to +60 °C, and the storage temperature range is -25 °C to +60 °C.
Compatibility and Accessories
The relay is suitable for networks with frequencies from 50 to 400 Hz and complies with the standard IEC/EN 60255-1. It is designed for three-phase networks without a neutral conductor and can be used in systems with or without a neutral conductor, depending on the variant. The contact configuration includes 2 changeover contacts, suitable for switching operations in AC 15 and DC 13 applications. The maximum switching capacity is 2 A at AC 230 V (make contact) and 1 A at AC 230 V (break contact). The electrical life expectancy is 2 x 10⁵ switching operations at 3 A and AC 230 V.
Mounting and Installation
The device is mounted on a DIN rail, with terminals complying with DIN 46228-1/-2/-3/-4. The connection cross-sections are 2 x 2.5 mm² for rigid conductors or 2 x 1.5 mm² for stranded conductors with sheathing. The terminals are equipped with self-clamping terminal blocks, to be tightened with a torque of 0.8 Nm. Installation is carried out in enclosures, with an operating altitude up to 2000 m above sea level.
Operational Advantages
Preventive maintenance and rapid fault localization increase productivity. The LED indicators enable visual monitoring of the operating status, and the simple adjustment via rotary potentiometers reduces commissioning time. The device is designed for continuous operation and has a mechanical life expectancy of over 30 x 10⁶ switching operations. The overvoltage category III and EMC testing according to IEC/EN 61000-4-2 to -4-5 ensure high immunity to interference.
Approvals and Markings
The device carries the UKCA marking and complies with the requirements of standard IEC/EN 60255-1. The rated impulse withstand voltage is 6 kV at pollution degree 2, ensuring high insulation strength. The short-circuit withstand capability is protected by a maximum fuse rating of 4 A gG/gL.
| Technical data | |
| 1- / 3-phase | 3 |
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | 3/N AC 690 / 400 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9043 |
| Operate delay | |
| Variant | |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3AC 690 V |
| Time delay | without |
| Approvals and Markings | UKCA |
| Variant | For 3p3w systems |
Questions & answers
What is the delivery time of Dold 0044746 BA9043/001 3AC50-400Hz 690V undervoltage relay ?
The article Dold 0044746 BA9043/001 3AC50-400Hz 690V undervoltage relay is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0044746 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0044746 BA9043/001 3AC50-400Hz 690V undervoltage relay always at the best possible price. We can give you a discount of 2% on Dold 0044746 BA9043/001 3AC50-400Hz 690V undervoltage relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0044746 BA9043/001 3AC50-400Hz 690V undervoltage relay we can offer you a price of 259,94 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.