Dold 0044505 MK9151.11 2-450 kOhm AC220-240 V level relay
|
169,19 EUR |
|||||||||||
|
( 201,34 EUR incl. VAT ) ≈ £141.61 | ≈ $185.94 plus delivery charges: 55,00 € |
|||||||||||
| Made to order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 540181 | ||||||||||
| Mfg Part No: | 0044505 | ||||||||||
| UPC/EAN: | 4030641445058 | ||||||||||
| Weight: | 0.175 kg | ||||||||||
| Type: | MK9151.112-450K-OHMAC220-240V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0044505:
Applications
This relay is designed for monitoring and controlling conductive liquids and powder materials. Typical applications include monitoring tanks in process industries, food processing, or water supply. It can be used for simple 1-point control (e.g., overfill or dry run protection) as well as 2-point control (e.g., maintaining fill level between minimum and maximum levels). The connection options for three electrodes allow for flexible configurations. The maximum cable length to the electrodes is 3000 meters, enabling reliable measurement over long distances.
Functions and Features in Detail
The device features an adjustable trigger value in the range of 2 to 450 kΩ, allowing differentiation between liquid and foam. The trigger and reset delay can be adjusted between 0.2 and 20 seconds to dampen mechanical switching operations and avoid unwanted switching impulses. Programming is available for either the operating current principle (without bridge, output relay activated in case of fault) or the resting current principle (bridge X1-X2 or X1-COM, output relay not activated in case of fault). The output contacts consist of a changeover contact, suitable for controlling pumps, solenoid valves, or other loads.
Technology Explained Simply
The measuring circuit generates an alternating current that flows through the connected electrodes. The electrical conductivity of the liquid affects the resistance in the measuring circuit, enabling detection of the fill level. Galvanic isolation of the measuring circuit from the mains minimizes interference from mains voltage fluctuations or other electrical influences. The maximum measuring voltage is approximately 10 V AC, generated internally. The maximum measuring current is approximately 1.5 mA in the range of 2–450 kΩ. The operating voltage for the auxiliary device is AC 220–240 V, with permissible voltage variation ranges of 0.8 to 1.1 times the nominal voltage (AC) and 0.85 to 1.25 times (DC). The nominal power is approximately 2 VA at AC voltage.
Compatibility and Accessories
The device is compatible with all commercially available electrodes. The reference electrode is typically mounted at the lowest point of the tank and connected to the COM terminal. In conductive tanks, the tank itself can serve as the reference electrode. The terminal connections are designed for connecting electrodes and controlling the output relay. Terminal markings include A1 (+/L), A2 (−/N), COM, MIN, MAX, X1, X2, and changeover contacts 11, 12, 14 and 21, 22, 24. Indication is provided by a green LED for operational readiness and a yellow LED for the output relay contact status.
Mounting and Installation
The device is mounted in enclosures and requires secure fixation in a suitable control cabinet. Electrodes must be positioned in the tank according to the desired fill level control. Wiring is done via the designated terminal connections. The maximum cable length to the electrodes is 3000 meters, with cable length varying depending on the resistance range. Installation must follow the manufacturer’s technical specifications, including consideration of galvanic isolation of the measuring circuit.
Operational Advantages
The relay offers high reliability due to galvanic isolation of the measuring circuit and adjustable delay time, which dampens mechanical switching operations. The wide adjustment range of 2 to 450 kΩ enables precise differentiation between liquid and foam. LED indicators facilitate visual monitoring of operational status. Compatibility with various electrodes and flexible programming for operating or resting current principles increases application versatility. Compliance with the standard IEC/EN 60255-1 ensures electrical safety and reliability of the device.
| Technical data | |
| Classification | Füllstandsüberwachung |
| Enclosure design | Switch cabinet |
| Measuring range max. | 450 kΩ |
| Output contacts | 1 C/O contact |
| Width | 22,5 mm |
| Type | MK 9151 |
| Operate delay | |
| Variant | |
| Auxiliary voltage | AC 220 - 240 V |
| Contact equipping | 1 changeover contact |
| Response value | 2 - 450 kOhm |
| Variant | Time delay, when level rises over and drops under setting value |
Questions & answers
What is the delivery time of Dold 0044505 MK9151.11 2-450 kOhm AC220-240 V level relay ?
The article Dold 0044505 MK9151.11 2-450 kOhm AC220-240 V level relay is currently not in stock and must be ordered on a per-order basis.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0044505 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0044505 MK9151.11 2-450 kOhm AC220-240 V level relay always at the best possible price. We can give you a discount of 2% on Dold 0044505 MK9151.11 2-450 kOhm AC220-240 V level relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0044505 MK9151.11 2-450 kOhm AC220-240 V level relay we can offer you a price of 162,85 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.