Further information for Dold 0044505 level relay 2-450 kOhm AC220-240V
Technical data
Classification
Füllstandsüberwachung
Enclosure design
Switch cabinet
Measuring range max.
450 kΩ
Output contacts
1 C/O contact
Width
22,5 mm
Type
MK 9151
Operate delay
Variant
Auxiliary voltage
AC 220 - 240 V
Contact equipping
1 changeover contact
Response value
2 - 450 kOhm
Variant
Time delay, when level rises over and drops under setting value
The Dold level relay MK9151.112-450K-OHMAC220-240V is an industrial device for monitoring the fill level of conductive liquids and powders. It is used for continuous monitoring of maximum and minimum fill levels, protection against overfilling or dry running, and regulation of mixing ratios in conductive liquids. The device is designed for use in enclosures and has a width of 22.5 mm, making it suitable for standard control panels. Level monitoring is performed via a measuring circuit that is galvanically isolated from the mains, providing high immunity to interference.
Applications
This relay is designed for monitoring and controlling conductive liquids and powder materials. Typical applications include monitoring tanks in process industries, food processing, or water supply. It can be used for simple 1-point control (e.g., overfill or dry run protection) as well as 2-point control (e.g., maintaining fill level between minimum and maximum levels). The connection options for three electrodes allow for flexible configurations. The maximum cable length to the electrodes is 3000 meters, enabling reliable measurement over long distances.
Functions and Features in Detail
The device features an adjustable trigger value in the range of 2 to 450 kΩ, allowing differentiation between liquid and foam. The trigger and reset delay can be adjusted between 0.2 and 20 seconds to dampen mechanical switching operations and avoid unwanted switching impulses. Programming is available for either the operating current principle (without bridge, output relay activated in case of fault) or the resting current principle (bridge X1-X2 or X1-COM, output relay not activated in case of fault). The output contacts consist of a changeover contact, suitable for controlling pumps, solenoid valves, or other loads.
Technology Explained Simply
The measuring circuit generates an alternating current that flows through the connected electrodes. The electrical conductivity of the liquid affects the resistance in the measuring circuit, enabling detection of the fill level. Galvanic isolation of the measuring circuit from the mains minimizes interference from mains voltage fluctuations or other electrical influences. The maximum measuring voltage is approximately 10 V AC, generated internally. The maximum measuring current is approximately 1.5 mA in the range of 2–450 kΩ. The operating voltage for the auxiliary device is AC 220–240 V, with permissible voltage variation ranges of 0.8 to 1.1 times the nominal voltage (AC) and 0.85 to 1.25 times (DC). The nominal power is approximately 2 VA at AC voltage.
Compatibility and Accessories
The device is compatible with all commercially available electrodes. The reference electrode is typically mounted at the lowest point of the tank and connected to the COM terminal. In conductive tanks, the tank itself can serve as the reference electrode. The terminal connections are designed for connecting electrodes and controlling the output relay. Terminal markings include A1 (+/L), A2 (−/N), COM, MIN, MAX, X1, X2, and changeover contacts 11, 12, 14 and 21, 22, 24. Indication is provided by a green LED for operational readiness and a yellow LED for the output relay contact status.
Mounting and Installation
The device is mounted in enclosures and requires secure fixation in a suitable control cabinet. Electrodes must be positioned in the tank according to the desired fill level control. Wiring is done via the designated terminal connections. The maximum cable length to the electrodes is 3000 meters, with cable length varying depending on the resistance range. Installation must follow the manufacturer’s technical specifications, including consideration of galvanic isolation of the measuring circuit.
Operational Advantages
The relay offers high reliability due to galvanic isolation of the measuring circuit and adjustable delay time, which dampens mechanical switching operations. The wide adjustment range of 2 to 450 kΩ enables precise differentiation between liquid and foam. LED indicators facilitate visual monitoring of operational status. Compatibility with various electrodes and flexible programming for operating or resting current principles increases application versatility. Compliance with the standard IEC/EN 60255-1 ensures electrical safety and reliability of the device.