This image may differ from the desired article.
268,13 EUR
( 319,07 EUR incl. VAT )
≈ £224.42  |  ≈ $294.67
plus delivery charges: 55,00 €
On order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0040804 AI 897 AC45-400Hz 400V 10-80kΩ insulation monitor
Datasheet:file_download Download
Lieske Part No.:1001657
Mfg Part No: 0040804
UPC/EAN: 4030641408046
Weight:0.245 kg
Type:AI 897 AC45-400HZ 400V 10-80K-OHM
Graduated prices net
From piecesPrice per pieces
4256,06 EUR
8244,00 EUR
12231,93 EUR
16219,87 EUR

Product information for Dold 0040804:

The Dold AI 897 AC45-400HZ 400V 10-80K-OHM is an insulation monitor for ungrounded AC and three-phase systems, developed in accordance with the standard IEC/EN 61557-8. The device is designed for continuous monitoring of insulation resistance in IT systems and detects a drop in insulation resistance below an adjustable threshold. It is intended for pure AC and three-phase systems and operates without auxiliary voltage, making it independent of additional power supplies. The width is 45 mm, enabling compact installation in standard enclosures.

Applications

The insulation monitor is intended for use in industrial and technical installations where safety is ensured by detecting insulation faults in the network. It is suitable for IT systems with nominal voltages from AC 24 to 500 V and frequencies between 45 and 400 Hz. Monitoring is performed via a measuring circuit connected to one phase; in three-phase systems, this is sufficient, as the phases are connected via the supplying transformer with low resistance (approximately 3–5 Ω), allowing faults on unconnected phases to be detected. Only one insulation monitor may be installed in a network to avoid false alarms.

Functions and Equipment in Detail

The device features an adjustable trigger value between 10 and 80 kΩ, which can be set continuously using a screwdriver. The trigger value is simulated via an internal test resistor corresponding to an earth resistance below 10 kΩ. The measuring voltage is DC 18 V, and the maximum measuring current at an earth resistance of 0 Ω is less than 0.1 mA. The response delay is less than 4.2 seconds when the earth resistance drops from infinite to 90 % of the trigger value at a trigger value of 50 kΩ and a capacitance of 1 μF. When dropping to 0 Ω, the delay is approximately 2 seconds.

Technology Explained Simply

The insulation monitor operates on the idle current principle, where the output relay is not activated in the event of a fault, but is only triggered via a changeover contact when an insulation fault occurs. The function is programmable: bridging terminals LT1 and LT2 activates memory behavior, where the alarm can only be reset via an external reset button. Without bridging, hysteresis behavior is active, where the alarm automatically resets when the insulation resistance rises above the trigger value again. The hysteresis is approximately 50 % at a trigger value of 50 kΩ. The trigger uncertainty is ±15 %.

Compatibility and Accessories

The device includes an integrated test button PT to check the device’s functionality. External test buttons can be connected to terminals PT1 and PT2. Similarly, external reset buttons can be connected to LT1 and LT2 to utilize memory behavior. The contact configuration consists of a changeover contact rated for a maximum switching voltage of AC 400 V. The thermal current is 6 A, and the switching capacity complies with standards IEC/EN 60947-5-1 (AC 15 and DC 13). The electrical life is at least 300,000 switching operations at 10 A and AC 250 V, and the mechanical life is at least 30 million switching operations.

Mounting and Installation

Mounting is performed in enclosures with a width of 45 mm. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +70 °C. The operating altitude is limited to below 2000 m. The housing protection rating is IP 40, protecting against contact with moving parts and solid objects. Creepage and clearance distances correspond to pollution degree 2 and a rated impulse voltage of 4 kV. The insulation test voltage is AC 2.5 kV for 1 second.

Operational Advantages

The insulation monitor provides reliable, low-maintenance monitoring without auxiliary voltage. The adjustable trigger threshold allows adaptation to the specific requirements of the network. The programmable functions for memory behavior and hysteresis enable flexible adaptation to operation. Integrated test and reset buttons, as well as the possibility to connect external buttons, enhance usability. EMC tests according to IEC/EN 61000-4-2 to -4-6 ensure robust operation in electromagnetically demanding environments. Radio frequency interference suppression complies with emission limit class B according to EN 55011.

Protection Rating and Environmental Conditions

The device is designed for indoor use, as the IP 40 protection rating does not provide weather protection. The operating temperature range is limited to -20 °C to +60 °C, with guaranteed functionality within the permissible voltage range. Storage is permitted up to +70 °C. The operating altitude is limited to below 2000 m above sea level.

Contacts and Switching Capacity

The contact configuration consists of a changeover contact. The maximum switching voltage is AC 400 V. The thermal current Ith is 6 A. The switching capacity complies with standards IEC/EN 60947-5-1: for AC 15, the switching capacity is 10 A / AC 230 V for the closing contact and 5 A / AC 230 V for the opening contact. For DC 13, it is 1 A / DC 24 V. The electrical life is at least 300,000 switching operations at 10 A and AC 250 V. The mechanical life is at least 30 million switching operations. The short-circuit withstand requires a maximum fuse rating of 5 A gG / gL.

EMC and Safety

The device meets the requirements of the EMC directive. Electrostatic discharge is 8 kV (air discharge) according to IEC/EN 61000-4-2. Radio frequency field strength is 10 V/m in the range 80 MHz to 2.7 GHz according to IEC/EN 61000-4-3. Fast transients are 2 kV according to IEC/EN 61000-4-4. Surge voltages between supply lines are 2 kV, and between lines and earth are 4 kV according to IEC/EN 61000-4-5. Conducted RF interference is 10 V according to IEC/EN 61000-4-6. Radio frequency interference suppression complies with emission limit class B according to EN 55011. The housing protection rating is IP 40 according to IEC/EN 60529.

Connection Terminals and Functions

Terminals A1 and A2 are for connecting the AC auxiliary voltage and the measuring circuit. PE is the connection for the protective conductor. PT1 and PT2 are for connecting an external test button. LT1 and LT2 are for connecting an external reset button or for programming memory or hysteresis behavior. Terminals 11, 12, and 14 are the connections for the alarm indicator relay (1 changeover contact). The functions are programmable: bridging LT1 and LT2 activates memory behavior, while no bridging activates hysteresis behavior.

Approvals and Markings

The device complies with standards IEC/EN 61557-8 and IEC/EN 60947-5-1. Approvals and markings are listed in the datasheet. The operating temperature range is limited to -20 °C to +60 °C, and the storage temperature range is -25 °C to +70 °C. The operating altitude is limited to below 2000 m. Creepage and clearance distances correspond to pollution degree 2 and a rated impulse voltage of 4 kV. The insulation test voltage is AC 2.5 kV for 1 second.

General Data

The nominal operating mode is continuous operation. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +70 °C. The operating altitude is limited to below 2000 m. Creepage and clearance distances correspond to pollution degree 2 and a rated impulse voltage of 4 kV. The insulation test voltage is AC 2.5 kV for 1 second. The housing protection rating is IP 40. EMC tests according to IEC/EN 61000-4-2 to -4-6 are fulfilled. Radio frequency interference suppression complies with emission limit class B according to EN 55011.

Functional Safety and Reliability

The insulation monitor AI 897 offers high reliability through the idle current principle and programmable functions. The adjustable trigger threshold and hysteresis ensure precise and disturbance-free alarm signaling. Integrated test and reset buttons, as well as the possibility to connect external buttons, enhance usability. EMC tests ensure robust operation in electromagnetically demanding environments. The mechanical life of at least 30 million switching operations and the electrical life of at least 300,000 switching operations at 10 A and AC 250 V guarantee a long service life.

Technical data
Auxiliary voltageWithout
Enclosure designSwitch cabinet
IMD typeAC
Nominal voltage IT systemAC 24 - 500 V
Response value10 - 80 kΩ
Response value typeAdjustable
Width45 mm
TypeAI 897
Variant
Alarm value10 - 80 kOhm
Contact equipping1 changeover contact
Nominal voltageAC 400 V 45 - 400 Hz
VariantSettable response value


Product data sheet
Datasheet for Dold 0040804, EAN: 4030641408046

Questions & answers

What is the delivery time of Dold 0040804 AI 897 AC45-400Hz 400V 10-80kΩ insulation monitor?

The article Dold 0040804 AI 897 AC45-400Hz 400V 10-80kΩ insulation monitor is currently not in stock but has been backordered.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0040804 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0040804 AI 897 AC45-400Hz 400V 10-80kΩ insulation monitor always at the best possible price. We can give you a discount of 2% on Dold 0040804 AI 897 AC45-400Hz 400V 10-80kΩ insulation monitor if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0040804 AI 897 AC45-400Hz 400V 10-80kΩ insulation monitor we can offer you a price of 256,06 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0040804 insulation monitor AI 897 AC45-400Hz 400V
Dold 0040804 AI 897 AC45-400Hz 400V 10-80kΩ insulation monitor
268,13 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0040804 insulation monitor AI 897 AC45-400Hz 400V
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
2 + 6 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.