Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay

Your rating:
Average rating
product review for Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay
( 4.5 / 5 ) 10 ratings
Dold 0035352
This image may differ from the desired article.
270,07 EUR
( 321,38 EUR incl. VAT )
≈ £226.05  |  ≈ $296.81
plus delivery charges: 55,00 €
Made to order · Delivery time approx. 20 workdaysinfo_outline
1x Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay
Datasheet:file_download Download
Lieske Part No.:1312746
Mfg Part No: 0035352
UPC/EAN: 4030641353520
Weight:0.34 kg
Type:BA9043/001 3AC50-400HZ 110V
Graduated prices net
From piecesPrice per pieces
4259,94 EUR
8249,81 EUR
12239,69 EUR
16229,56 EUR

Product information for Dold 0035352:

The Dold undervoltage relay BA9043/001 3AC50-400Hz 110V is a 3-phase monitoring device for three-phase AC networks without a neutral conductor. It is designed for continuous monitoring of the supply voltage and de-energizes output contacts in case of undervoltage to prevent damage to connected devices. The device is rated for nominal voltages of 3 AC 110 V and can be used in networks with frequencies from 50 to 400 Hz. Measurement is performed via arithmetic mean calculation, where phases L1 and L2 are measured against L3, as no neutral conductor connection is available. Device settings are adjusted via rotary potentiometers on the front panel, allowing the pickup and dropout values to be continuously adjusted between 0.85 and 1.05 of the nominal voltage, with a hysteresis of 0.75 to 0.95 of the pickup value.

Applications
This relay is designed for industrial applications and railway applications. It monitors 3-phase AC networks and is particularly suitable for systems where stable voltage supply is critical. The device is installed in enclosures and has a width of 45 mm, allowing integration into standard DIN rail mounting. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +60 °C.

Functions and Equipment in Detail
The device operates on the zero-current principle, meaning the output relay is not activated in the event of a fault. The output contacts consist of two changeover contacts, designed for switching operations with a thermal current of up to 6 A per contact. Switching capacities are 2 A / AC 230 V for closing contacts and 1 A / AC 230 V for opening contacts according to IEC/EN 60947-5-1. The electrical life expectancy is at least 200,000 switching operations at 3 A and AC 230 V, while the mechanical life expectancy exceeds 30 million switching operations. Indication is provided via LEDs: a red LED indicates that supply voltage is present, and a green LED signals the activated state of the output relay.

Technology Explained Simply
Voltage measurement is performed by arithmetic mean calculation of the three phases. In the variant without a neutral conductor (BA9043/001), phases L1 and L2 are measured against L3 to determine the mean value. The pickup delay is active, but no time delay is available for this variant. The overload capacity is 1.2 times the nominal voltage continuously. The nominal power consumption is 4 VA. The device is insensitive to harmonics, meaning it operates reliably even with supply voltages containing harmonic distortions. The frequency tolerance is ±5 %.

Compatibility and Accessories
The relay is available for networks with or without a neutral conductor, with the BA9043/001 variant specifically designed for systems without a neutral conductor. It is compliant with IEC/EN 60255-1 and carries the UKCA and CCC certifications. Mounting is on DIN rails according to IEC/EN 60715. The connection terminals are designed for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with heat shrink tubing, with a stripping length of 10 mm. Fixing is done using M3.5 plus-minus screws with self-lifting inserts, with a torque of 0.8 Nm.

Mounting and Installation
Installation is carried out in enclosures on DIN rails. The connection terminals are clearly labeled: L1, L2, L3 for the supply connections and 11, 12, 14 as well as 21, 22, 24 for the two changeover contacts. Adjustment of pickup and dropout values is performed via the rotary potentiometers on the front panel. The LED indicators allow for quick visual inspection of the operating status. The operating altitude is limited to a maximum of 2000 m above sea level.

Advantages in Operation
The continuous adjustability of pickup and dropout values, as well as the hysteresis, allows the device to be adapted to different requirements. The LED indicators enable quick fault localization. The zero-current principle ensures that no unwanted activation of the output contacts occurs in the event of a fault. Insensitivity to harmonics increases reliability in networks with non-sinusoidal voltage waveforms. Compliance with the IEC/EN 60255-1 standard and the UKCA and CCC certifications ensure suitability for use in various markets.

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.3/N AC 690 / 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9043
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3AC 110 V
Time delaywithout
Approvals and MarkingsUKCA, CCC
VariantFor 3p3w systems


Product data sheet
Datasheet for Dold 0035352, EAN: 4030641353520

Questions & answers

What is the delivery time of Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay ?

The article Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay is currently not in stock and must be ordered on a per-order basis.

According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0035352 to our sales team for an exact delivery time.

How can I buy the item at a lower price?

We offer you Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay always at the best possible price. We can give you a discount of 2% on Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay if you choose payment in advance on ordering.

In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay we can offer you a price of 259,94 EUR per piece. The more you buy, the cheaper the article will be.

We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.

 


Searching
Search is performed.
Please be patient ...
Fehlende Felder
Close
Product in the shopcart

The following item has been put into your shopping cart by our system:

1x Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay
Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay
270,07 EUR
Sum of all articles in cart
plus VAT
You can continue shopping and open your cart at any time from the top menu bar or now directly by clicking the button.
Enquiry: Dold 0035352 BA9043/001 3AC50-400Hz 110V undervoltage relay
Company name
Name
Homepage
Street
ZIP-Code City
Country
Telephone
Desired quantity
Comment
1 + 2 =
Data protection notice: The data entered here will only be electronically stored and processed for the purpose of responding to your inquiry in accordance with Art. 6 GDPR para. 1b. The basis for this is our privacy policy.
Name and email address are the only mandatory fields.

We use cookies. Some are required to run the shop (e.g. shopping cart and login), others help us improve it (Google Analytics). Statistics cookies are only used with your consent. See our privacy policy for details.