Dold 0029922 BA9036 DC127V + RV D.FOLG.POS. voltage relay
|
233,82 EUR |
|||||||||||
|
( 278,25 EUR incl. VAT ) ≈ £195.71 | ≈ $256.97 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1002190 | ||||||||||
| Mfg Part No: | 0029922 | ||||||||||
| UPC/EAN: | 4030641299224 | ||||||||||
| Weight: | 0.34 kg | ||||||||||
| Type: | BA9036 DC127V + RV D.FOLG.POS. | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0029922:
Applications
This relay is suitable for applications in industrial electrical engineering, particularly in installations requiring high operational reliability, such as in manufacturing automation, power supply, or building automation. It monitors voltages in the range of 24 to 400 V, with the nominal voltage for this variant being DC 127 V. The maximum nominal voltage is AC 400 V. The devices are specified according to IEC/EN 60255-1, ensuring high reliability and standard conformity. Monitoring is for single-phase systems, with setting ranges between 0.85 and 1.05 of the nominal voltage. For the variant /1_ _, the setting range is 0.9 to 1.25 of the nominal voltage.
Functions and Equipment in Detail
The relay features 2 changeover contacts as output contacts, which can be used for controlling auxiliary functions or alarms. The contacts are rated for a thermal current of 6 A and have a switching capacity according to AC 15 (make: 2 A / AC 230 V, break: 1 A / AC 230 V) and DC 13 (make: 1 A / DC 24 V, break: 1 A / DC 24 V). The electrical life is 150,000 switching operations at 6 A and AC 230 V, while the mechanical life is 30 million switching operations. The reset ratio (hysteresis) is between 0.75 and 0.95 of the set value, ensuring stable and reliable switching performance. The repeatability accuracy is ±0.5 %, enabling high precision in setting.
Technology Explained Simply
The device operates without auxiliary voltage, meaning it is directly connected to the voltage source to be monitored. The response delay is activated and can be set between 0.5 and 10 seconds, with the delay only effective when the voltage is above 60 % of the nominal voltage. This prevents unwanted switching operations during short-term voltage fluctuations. Operational readiness and contact status are indicated by LED displays: the upper LED lights up when operating voltage is present, and the lower LED lights up when the output relay is activated. For DC voltages above 60 V, an external resistor is required, connected to terminals e and z. For the DC 127 V variant, the resistor ZWS 20 SL 1.6 kΩ 20 W is specified.
Compatibility and Accessories
The relay is designed for use in enclosures and can be mounted in standard control panels. It is compatible with an external resistor required for DC voltages above 60 V. Accessories are listed in the datasheet under Accessories and Spare Parts, with the resistor ZWS 20 SL 1.6 kΩ 20 W specified for the DC 127 V variant. The devices are designed for operation in a temperature range of -20 °C to +60 °C, with identical specifications for operation and storage.
Mounting and Installation
Mounting is done in an enclosure, with the 45 mm width enabling standard mounting on DIN rails. Connections are made at terminals e, f, and z, with the measured voltage connected to e and f, and the external resistor connected to e and z. Terminal z is exclusively for the resistor. Mounting the resistor requires special caution, as it becomes very hot during operation and must be protected against contact and kept at sufficient distance from adjacent components.
Advantages in Operation
Early detection of voltage drops and preventive maintenance increase operational safety. The LED indicators enable quick fault localization, and the adjustable response and reset values allow application-specific adaptation. The high mechanical and electrical life, along with reliability according to IEC/EN 60255-1, make the relay a robust solution for industrial applications. Operational safety is further enhanced by the response delay and hysteresis, preventing unwanted switching operations during short-term disturbances.
| Technical data | |
| 1- / 3-phase | 1 |
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | AC 400 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9036 |
| Operate delay | |
| Variant | |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | DC 127 V |
| Time delay | without |
| Approvals and Markings | CCC |
| Variant | Undervoltage relay. Closed circuit operation |
Questions & answers
What is the delivery time of Dold 0029922 BA9036 DC127V + RV D.FOLG.POS. voltage relay?
The article Dold 0029922 BA9036 DC127V + RV D.FOLG.POS. voltage relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0029922 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0029922 BA9036 DC127V + RV D.FOLG.POS. voltage relay always at the best possible price. We can give you a discount of 2% on Dold 0029922 BA9036 DC127V + RV D.FOLG.POS. voltage relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0029922 BA9036 DC127V + RV D.FOLG.POS. voltage relay we can offer you a price of 223,30 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.