Product information for Dold 0028540:
Applications
The BA 9036 is designed for voltage monitoring in industrial and technical installations, particularly in systems requiring continuous power supply. It is suitable for applications in automation technology, power supply, and process control, where stable voltage is critical for smooth operation. Monitoring is performed for DC and AC voltages in the range of 24 to 400 V, with precise adjustment achieved via the rotary switch.
Functions and Features in Detail
The relay features two changeover contacts as output contacts, used for switching operations in control and protection circuits. The pickup delay is activated and can be set between 0.5 and 10 seconds, with the delay only effective when voltage exceeds 0.6 times the nominal voltage. The reset values are hysteresis-controlled and range between 0.75 and 0.95 of the set pickup value. Repeatability is ± 0.5 %, ensuring high precision in voltage monitoring. Operational readiness and contact status are indicated by LED displays: the upper LED lights up when operating voltage is present, and the lower LED indicates activation of the output relay.
Technical Explanation
The relay monitors the supply voltage and responds when it falls below a set threshold. In case of undervoltage, it switches the output contacts to, for example, activate a protective switch or trigger an alarm. Adjustment is made via a rotary switch, allowing pickup values between 0.85 and 1.05 times nominal voltage. For variant /1_ _, the adjustment range is 0.9 to 1.25 times nominal voltage. The pickup delay prevents unwanted switching during brief voltage fluctuations. Contacts are rated for a thermal current of 6 A and meet switching capacities according to AC 15 (make: 2 A / AC 230 V, break: 1 A / AC 230 V) and DC 13 (make: 1 A / DC 24 V, break: 1 A / DC 24 V). Electrical life is 150,000 switching operations at 6 A and AC 230 V, while mechanical life is 30 million switching operations.
Compatibility and Accessories
For DC 110 V operating voltage, an external resistor is required, connected to terminals e and z. The measured voltage is connected to terminals e and f. The resistor ZWS 20 SL with 1.5 kΩ and 20 W is intended for this purpose. Use of an external resistor is necessary because the voltage exceeds 60 V. Terminal z is exclusively for the resistor. The devices are operational without auxiliary voltage.
Mounting and Installation
The relay is designed for mounting in enclosures and conforms to the enclosure mounting form. Mounting is performed in a vertical position, with terminals accessible for connection wires. Operating and storage temperature ranges are between -20 °C and +60 °C. Maximum overload capacity is 1.2 times nominal voltage continuously. Nominal frequency is 50 or 60 Hz, with a frequency range of ±5 %. Temperature dependence of the measured value is < 0.05 %/K, indicating very low sensitivity.
Operational Advantages
Early detection of voltage drops enables preventive maintenance and reduces the likelihood of failures. LED indicators simplify diagnosis and fault localization. Simple adjustment via rotary switch reduces commissioning time. High contact life and robust construction ensure reliable performance over a long period. CCC certification confirms compliance with applicable safety standards.
| Technical data | |
| 1- / 3-phase | 1 |
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | AC 400 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9036 |
| Operate delay | |
| Variant | |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | DC 110 V |
| Time delay | without |
| Approvals and Markings | CCC |
| Variant | Undervoltage relay. Closed circuit operation |
Questions & answers
What is the delivery time of Dold 0028540 BA9036 DC110V + RV D.FOLG.POS. voltage relay?
The article Dold 0028540 BA9036 DC110V + RV D.FOLG.POS. voltage relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0028540 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0028540 BA9036 DC110V + RV D.FOLG.POS. voltage relay always at the best possible price. We can give you a discount of 2% on Dold 0028540 BA9036 DC110V + RV D.FOLG.POS. voltage relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 5 pieces of Dold 0028540 BA9036 DC110V + RV D.FOLG.POS. voltage relay we can offer you a price of 223,30 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.