Applications
This relay is suitable for industrial applications as well as railway applications. It monitors 3-phase AC networks and is particularly intended for systems requiring high availability. The operating temperature ranges from -20 °C to +60 °C, making it suitable for use in demanding climatic environments.
Functions and Equipment in Detail
The device features two changeover contacts as output contacts, designed for switching operations with a thermal current of up to 6 A per contact. Switching capacities are 2 A / AC 230 V for closing contacts and 1 A / AC 230 V for opening contacts according to AC 15 (IEC/EN 60947-5-1). The electrical life expectancy is at least 200,000 switching operations at 3 A and AC 230 V. The mechanical life expectancy exceeds 30 million switching operations. LED indicators signal operational readiness (red LED) and activation of the output relay (green LED). The fail-safe principle ensures that the output relay is not activated in case of fault, increasing safety.
Technology Explained Simply
The time delay is adjustable and ranges from 0.5 to 10 seconds. However, it only applies if the voltage is at least 60 % of the nominal voltage. Below 40 % of the nominal voltage, the output relay drops out immediately. Adjustment is made via a rotary potentiometer on the front panel. The devices comply with IEC/EN 60255-1 and are designed for use in enclosures. The width is 45 mm, allowing mounting on DIN rail. The devices are insensitive to harmonics, making them suitable for networks with non-linear loads.
Compatibility and Accessories
The relay is available for networks with or without neutral conductor, with the BA9043/002 variant specifically designed for systems with neutral conductor. The adjustable time delay makes it suitable for applications with short-term voltage dips. The devices are designed for frequencies from 50 to 400 Hz, which is also relevant for railway applications. The devices are designed for use in overvoltage category III and have a rated impulse withstand voltage of 6 kV at pollution degree 2.
Mounting and Installation
Mounting is on DIN rail according to IEC/EN 60715. The terminal connections are rated for 2 x 2.5 mm² solid or 2 x 1.5 mm² stranded zinc-coated cable. Cable fixation is achieved via M3.5 plus-minus screws with self-releasing clamp lever. Dimensions are 45 mm (width) x 73 mm (height) x 132 mm (depth). Mounting requires no additional auxiliary voltage, as the device is directly powered from the monitored network.
Advantages in Operation
Preventive maintenance is supported by rapid fault localization. The LED indicators enable visual monitoring of the operational status. The adjustable pickup and dropout values, as well as the time delay, allow application-specific adaptation. Harmonic insensitivity ensures stable operation even in networks with non-linear loads. The construction according to IEC/EN 60255-1 ensures high reliability and safety.
Approvals and Markings
The device carries the UKCA mark, confirming compliance with applicable European safety and performance requirements. The devices are intended for use in industrial and railway applications and meet the requirements of overvoltage category III. EMC requirements are fulfilled according to IEC/EN 61000-4-2 to -4-5, including protection against electrostatic discharge (8 kV), high-frequency radiation (20 V/m), and fast transients (2 kV).
| Technical data | |
| 1- / 3-phase | 3 |
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | 3/N AC 690 / 400 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9043 |
| Operate delay | |
| Variant | |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3/N 254/440 V |
| Time delay | 0,5 - 10 s |
| Approvals and Markings | UKCA |
| Variant | For 3p4w systems. With adjustable time delay |
Questions & answers
What is the delivery time of Dold 0027056 BA9043/002 3/N AC50-400Hz 254/440V under-voltage relay 0.5-10s?
The article Dold 0027056 BA9043/002 3/N AC50-400Hz 254/440V under-voltage relay 0.5-10s is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0027056 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0027056 BA9043/002 3/N AC50-400Hz 254/440V under-voltage relay 0.5-10s always at the best possible price. We can give you a discount of 2% on Dold 0027056 BA9043/002 3/N AC50-400Hz 254/440V under-voltage relay 0.5-10s if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0027056 BA9043/002 3/N AC50-400Hz 254/440V under-voltage relay 0.5-10s we can offer you a price of 280,03 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.