Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay
|
262,20 EUR |
|||||||||||
|
( 312,02 EUR incl. VAT ) ≈ £219.46 | ≈ $288.16 plus delivery charges: 55,00 € |
|||||||||||
| On order · Delivery time approx. 20 workdaysinfo_outline | |||||||||||
| Datasheet: | file_download Download | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Lieske Part No.: | 1153815 | ||||||||||
| Mfg Part No: | 0026904 | ||||||||||
| UPC/EAN: | 4030641269043 | ||||||||||
| Weight: | 0.34 kg | ||||||||||
| Type: | BA9043/001 3AC50-400HZ 220V | ||||||||||
|
Graduated prices net
|
|||||||||||
Product information for Dold 0026904:
Applications
This relay is suitable for industrial applications as well as railway applications where reliable voltage monitoring is required. It is mounted in enclosures and designed for continuous operation. The operating temperature range is from -20 °C to +60 °C, and the storage temperature range is from -25 °C to +60 °C. The maximum operating altitude is 2000 m above sea level. The devices are manufactured in accordance with IEC/EN 60255-1 and meet the requirements of overvoltage category III.
Functions and Equipment in Detail
The BA9043/001 features two changeover contacts as output contacts, designed for switching operations with a thermal current of up to 6 A per contact. The switching capacity is 2 A at 230 V AC according to AC 15. The electrical service life is 200,000 switching cycles at 3 A and 230 V, while the mechanical service life exceeds 30 million switching cycles. The contacts are designed according to the rest current principle, meaning the output relay is not activated in the event of a fault. Operating readiness is indicated by a red LED, and contact position is indicated by a green LED.
Technology Explained Simply
The arithmetic mean value measurement ensures that the total voltage of the three-phase network is monitored, even if individual phases deviate. In this variant, there is no time delay, so the relay disconnects immediately when the voltage drops below 0.4 of the nominal voltage. The pickup delay is active, meaning the device introduces a short delay upon voltage restoration before reactivating. The devices are insensitive to harmonics, making them suitable for networks with harmonic distortions.
Compatibility and Accessories
The relay is designed for 3-phase networks without a neutral conductor and can be used in systems with frequencies from 50 to 400 Hz. It has a width of 45 mm for mounting on DIN rail. The terminals are rated for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with heat-shrink tubing. Mounting is done using M3.5 plus-minus screws with self-locking terminals. The maximum overload capacity is 1.2 times the nominal voltage continuously. The nominal power consumption is 4 VA.
Mounting and Installation
Mounting is on DIN rail in accordance with IEC/EN 60715. Cable connections are made via the designated terminals, with a stripping length of 10 mm. The tightening torque is 0.8 Nm. The devices are designed for use in enclosures and comply with EMC directive requirements, including immunity to electrostatic discharge (8 kV), high-frequency radiation (20 V/m), and fast transients (2 kV). The rated impulse voltage is 6 kV at pollution degree 2.
Advantages in Operation
The adjustable pickup and dropout values allow precise adaptation to specific applications. The LED indicators facilitate fault localization and operational monitoring. Harmonic insensitivity ensures reliable operation even in networks with high harmonics. Simple adjustment via rotary potentiometers reduces setup time and minimizes errors during commissioning. The UKCA and CCC certifications confirm compliance with applicable safety and quality standards.
More spare projector bulbs for your Epson Beamer
| Technical data | |
| 1- / 3-phase | 3 |
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Nominal voltage max. | 3/N AC 690 / 400 V |
| Output contacts | 2 C/O contacts |
| Width | 45 mm |
| Type | BA 9043 |
| Operate delay | |
| Variant | |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3AC 220 V |
| Time delay | without |
| Approvals and Markings | UKCA, CCC |
| Variant | For 3p3w systems |
Questions & answers
What is the delivery time of Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay?
The article Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay is currently not in stock but has been backordered.
According to our experience the article is ready for dispatch within 20 working days. The delivery time usually refers to 1 piece. When ordering larger quantities, we can maybe shorten the delivery time. Just send us an inquiry about the desired quantity of Dold 0026904 to our sales team for an exact delivery time.
How can I buy the item at a lower price?
We offer you Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay always at the best possible price. We can give you a discount of 2% on Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay if you choose payment in advance on ordering.
In addition, you can save money with our attractive graduated prizes with every purchase. If you buy a minimum of 4 pieces of Dold 0026904 BA9043/001 3AC50-400Hz 220V undervoltage relay we can offer you a price of 250,40 EUR per piece. The more you buy, the cheaper the article will be.
We also offer individual prices for your needs. You can get an offer by using the form Wholesale Inquiry.